AWARD
45 -- HVAC Repair NAG Bldg 20451 Rooms 205,210, 211 &212, Kirtland AFB, NM.
- Notice Date
- 1/24/2014
- Notice Type
- Award Notice
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- USACE District, Albuquerque, CESPA-CT, 4101 Jefferson Plaza NE, Albuquerque, NM 87109-3435
- ZIP Code
- 87109-3435
- Solicitation Number
- W912PP14P0009
- Archive Date
- 2/23/2014
- Point of Contact
- Glenda Kohlieber, 575-556-9940
- E-Mail Address
-
USACE District, Albuquerque
(glenda.d.kohlieber@usace.army.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W912PP14P0009
- Award Date
- 1/22/2014
- Awardee
- ORTEGA PLUMBING AND HEATING INC (615720880) <br> 38 HACIENDA DEL VALLE <br> PERALTA, NM 87042-8506
- Award Amount
- $106,062.93
- Line Number
- 0001
- Description
- This contract action was accomplished using other than competitive procedures because a statute exists that expressly authorizes or requires that the acquisition be made from a specific source or through another agency (FAR 6.302-5); specifically, Sole source awards under the 8(a) Program. Per FAR 6.302-5 a J&A is not required for this award. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for Building 20451 National Assessment Group (NAG) HVAC Work in Rooms 205, 210, 211, 212. The work shall include the following requirements listed in the specific requirements. The contractor shall assure the attached checklist and DD Form 1354 are completed and submitted to USACE and Kirtland AFB Reap Property office to get it staffed to the BCE for signature, at the conclusion of the project. SPECIFIC REQUIREMENTS: Contractor to Install 1 complete VRV-III heating and Cooling System. Equipment provided will be 1 Heat Recovery VRV Condenser 230 volt. Contractor shall install 8 round flow ceiling mounted heat pump cassettes. Contractor shall install 1 VAM energy recovery ventilator to be located in mechanical room. Contractor shall install all refrigerant lines, condensate lines, control wiring and 4 Navigation Remote Controllers. Condenser will be located on north wall on a standard concrete housekeeping pad. All electrical needed for a complete system. Testing and balance will not be required.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA47/Awards/W912PP14P0009.html)
- Record
- SN03274127-W 20140126/140124234341-1c4ff1d47f7e1816a63c9a28750a06e0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |