DOCUMENT
66 -- Refrigeration, Lab and Med Grade - Attachment
- Notice Date
- 1/14/2014
- Notice Type
- Attachment
- NAICS
- 423740
— Refrigeration Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office;NCO 19;4100 E. Mississippi Avenue, Suite 900;Glendale CO 80246
- ZIP Code
- 80246
- Solicitation Number
- VA25914Q0176
- Response Due
- 1/22/2014
- Archive Date
- 2/21/2014
- Point of Contact
- Robert Smith
- E-Mail Address
-
robert.smith17@va.gov
(robert.smith17@va.gov)
- Small Business Set-Aside
- N/A
- Description
- Functional and Performance Specifications R6200 - Refrigerator, U/C, LAB QUALITY Colorado Springs Clinic GENERAL SPECIFICATIONS The Contractor will provide all tools, labor and materials for fabrication/ manufacturing and delivery of the following Laboratory Equipment Items in this document. The scope includes: o This is an Exact Match solicitation. o Vendor must honor pricing for 30 days. 1.Medical Grade Refrigerator, Under counter, ADA Compatible a.Quantity =9 b.Equivalency = Follet, REF4-ADA Compatible c.Capacity = 4.0 Cubic Feet d.Specifications = i.Key Features, Minimum Requirements 1.Medical Grade Refrigerator with external temperature display in F or C. Provides secure, stable temperature storage for patient floor, lab and pharmacy applications. Stainless steel interior/exterior. 2.Consistent temperature performance, security 3.Heavy duty ¼ hp compressor, forced air cooling and digital microprocessor controller maintain uniform cabinet temperatures with quick pull-down and rapid recovery following door openings. 4.Adjustable set point meets temperature needs for different applications 5.Locking door handle provides medication security 6.Supports Joint Commission standards for medication storage 7.NSF-listed; ensure temperature stability in adverse ambient 8.UL and cUL Listed 9.Easy to read external temperature display in F or C allows easy logging without opening door 10.Positive locking door latch and magnetic gasket provide secure closure 11.Two, easy to clean, epoxy-coated shelves 12.Rear port for easy alarm probe accessory entry 13.Front-breathing design requires no side, top or back clearance 14.Field-reversible door provides left or right opening flexibility 15.Automatic, off-cycle defrost eliminates manual defrosting 16.Condensation evaporates automatically 17.Durable stainless steel interior and exterior for easy cleaning 18.Rear slide-out condensing unit provides complete access ii.Refrigerant 1.Dimensions (WxDxH) = 23.75" x 28.5" 31.25" 2.Electrical a.115V, 60 Hz, 1 ph, 8.0 amps, max fuse 15 amps b.6' hospital-grade cord and NEMA 5-15 plug provided 3.Max Heat Rejection - 717 BTU/hr 4.Refrigerant - R404A, 7.9 oz 2.Laboratory Series Single Door Upright Refrigerator a.Quantity = 5 b.Equivalency = Follet, REF20-LAB, c.Capacity = 19.7CF d.Specifications = i.Key Features, Minimum Requirements 1.Storage System a.Four(4) Expoxy-coated shelves b.Operating range Factory preset at 4C, user -adjustable 1C-10C c.Door Dual pane, low-E glass, condensation free to 26C (80F) air/60% RH d.Interior/Exterior material Heavy duty, corrosion resistant stainless steel e.Display 3" LCD temperature display with 0.1C/F resolution. Factory set to display in C, User selectable Cor F display. f.Alarms High/Low temperature, power failure, door ajar, low battery, probe error; adjustable alarm mute interval (up to 60 min) g.Monitoring RS-485 port h.NO/NC contacts for remote monitoring, alarming i.Casters (4) dual-wheel swiveling casters with two (2) toe locks j.Insulation Energy saving 2.75" thick, CFD free foam insulation throughout. k.Refrigeration system single top mounted module with 1/3 hp air cooled compressor, non CFC R-134a refrigerant l.Air circulation system ducted air through 12 back plenum openings with front face return m.Temperature probe stainless steel RTD top immersible n.Clearance 10" on top o.Holds better than 1C temperature at all levels in the cabinet 2.Dimensions (WxDxH) = 29.75" x 30.5" x 79.5" 3.Electrical a.115V, 60 Hz, 8.7 amps, max fuse 15 amps b.8' hospital-grade cord and NEMA 5-15 plug provided, 14A/125V 3-pront plug c.Voltage Range 103-132V 4.Max Heat Rejection - 950 BTU/hr 5.Refrigerant - R404A, 7.9 oz 6.Average Energy Consumption 4.8kWh/day all models 3.Medical Grade Under Counter -20C Freezer - ADA Compatible e.Quantity = 1 f.Equivalency = Follet, FZR4-ADA g.Capacity = 3.5 CF h.Specifications = i.Key Features, Minimum Requirements 1.Automatic Defrost 2.External Temperature display 3.Stable Temperature Storage for Patient Floor/Lab, Pharmacy 4.Factory Set at -25C 5.Set point adjustable -30C to 15C 6.Heavy Duty 1/3 HP compressor, forced air cooling, digital microprocessor controller and thermal expansion valve TXV 7.Provide Stable Temperature, quick temperature pull down and rapid recovery following door openings and defrost cycles 8.Temperature -terminated automatic defrost ensures product integrity during defrost 9.Digital microprocessor controller incorporates defrost control eliminating need for external, mechanical timer 10.Positive, locking door latch and magnetic gaskets provides secure closer and product security 11.Supports Joint Commission, CDC and VFC standards for vaccine and medication storage 12.To epoxy-coated shelves adjust for varied product 13.Front breathing design requires no top, back or side clearances 14.Rear slide-out condensing unit provides complete access 15.Dimensions (WxDxH) = 23.75" x 28.5" x 31.25" 16.Electrical a.115V, 60 Hz, 8 amps, max fuse 15 amps b.Hospital-grade cord and NEMA 5-15 plug provided c.Voltage Range 103-132V 17.Max Heat Rejection - 890 BTU/hr 18.Refrigerant - R404A, 7.9 oz 1.DELIVERY a.Contractor to provide delivery to VA Warehouse located at 1055 Clermont Street, Denver, CO 80220. b.Driver to remove pallet from truck and bring inside of warehouse building c.Provide a 48 hour notice to VA POC before delivery is made. 2.Installation a.Contractor to provide installation services after delivery to VA site. Coordination to be conducted between VA rep, Anisa Jones and Vendor. 3.GUARANTEE a.The equipment supplier shall guarantee all material and workmanship of equipment provided under the contract for a period of two (2) years Any defects due to use of improper materials or workmanship occurring within that time shall be promptly rectified by the equipment supplier at his own expense upon notification by the Owner or Architect. VENDOR SHALL SUBMIT SPECIFICATIONS, CUT SHEETS, PLANS AND/OR DRAWINGS FOR EACH LINE ITEM LISTED ABOVE.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25914Q0176/listing.html)
- Document(s)
- Attachment
- File Name: VA259-14-Q-0176 VA259-14-Q-0176.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1161397&FileName=VA259-14-Q-0176-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1161397&FileName=VA259-14-Q-0176-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA259-14-Q-0176 VA259-14-Q-0176.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1161397&FileName=VA259-14-Q-0176-000.docx)
- Place of Performance
- Address: VA Colorado Springs Clinic;3139 Centennial Blvd.;Colorado Springs, CO. 80907