43 -- WATER PUMP MOTOR - Attachment

Notice Date
1/13/2014
 
Notice Type
Attachment
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Activity 8;Commerce Building;300 E. University Ave. Ste. 180;Gainesville FL 32601-3460
 
ZIP Code
32601-3460
 
Solicitation Number
VA24814Q0337
 
Response Due
1/10/2014
 
Archive Date
1/25/2014
 
Point of Contact
Christopher Brailer
 
Small Business Set-Aside
Total Small Business
 
Description
2nd Amendment to Solicitation VA248-14-Q-0337. (Newest answers to questions in bold below) The purpose of the following amendment is to: Extends the response date from 01/10/2014 to 01/17/2014. Answer questions submitted by prospective vendors (see below). CONSOLIDATED QUESTIONS AND ANSWERS (1/13/14) Solicitation # VA248-14-Q-0337 QUESTIONS: All questions regarding this solicitation must be submitted to the Contracting Specialist in writing (email is acceptable). Any prospective bidder desiring an explanation or interpretation of the solicitation must request it in writing to the Contracting Officer: Christopher Brailer (christopher.brailer@va.gov) No Later Than: close of business on January 9, 2014. No phone responses will be accepted. See FAR 52.214-6 Explanation to Prospective Bidders for additional information. Q: Where is the location for delivery? A: Malcom Randall VA Medical Center 1601 SW Archer Road, Gainesville, FL 32608 Q: Do you need the quote FOB destination? A: FOB Destination. Q: DO you have a model number for this motor? A: The SPEC# of the current motors is SPEC #: BAL18E577X765. There is no catalogue number. Q: Is the customer going to use 230 or 460 volts? A: 460 Volts. Q: What is the turn-down ratio of the motor? A: Per the response from the customer, "These motors are currently on VFD's. They have to be inverter duty motors. The original problem is that when they installed the plant, the Chilled Water Pumps were put on VFD's (Variable Frequency Drive) without being rated as inverter duty motors. We are working to correct this. The impellers were not shaved down as far as I know, because the pumps were going to be run with VFD's. We need premium efficiency inverter duty motors to replace the old motors." The customer is under the impression that what they need does not have a turn-down ratio. If there is one associated with an inverter duty rated motor, he does not know what it would be.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANFSGHS/DVANoFSoGHS/VA24814Q0337/listing.html)
 
Document(s)
Attachment
 
File Name: VA248-14-Q-0337 VA248-14-Q-0337_3.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1158807&FileName=VA248-14-Q-0337-002.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1158807&FileName=VA248-14-Q-0337-002.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN03266339-W 20140115/140113235533-b70cf461dcf7a59b7b7f5565b3bf8e74 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.