Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 19, 2013 FBO #4408
DOCUMENT

43 -- WATER PUMP MOTOR - Attachment

Notice Date
12/17/2013
 
Notice Type
Attachment
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Activity 8;Commerce Building;300 E. University Ave. Ste. 180;Gainesville FL 32601-3460
 
ZIP Code
32601-3460
 
Solicitation Number
VA24814I0290
 
Response Due
12/23/2013
 
Archive Date
1/7/2014
 
Point of Contact
Christopher Brailer
 
Small Business Set-Aside
N/A
 
Description
This is a Sources Sought Notice only. The NF/SG Veterans Healthcare System, 1601 SW Archer Road, Gainesville, FL 32608 is conducting market research to determine the availability of small businesses capable of providing Baldor Reliance custom water chiller pump motors for the Gainesville VAMC. The applicable NAICS code is 33415. Interested contractors are requested to submit a capability statement outlining their ability to meet or exceed this potential requirement no later than 4:30 pm (Eastern Standard Time), December 23, 2013 stating their business size, as well as a point of contact. Interested contractors must be registered in SAM. The government will use the results of this announcement to determine whether the acquisition of the above described requirement should be solicited as a small business set-aside, or whether full and open competition procedure should be utilized. THIS NOTICE IS NOT A REQUEST FOR COMPETITIVE QUOTES and no solicitation will be issued; This Sources Sought Notice is to assist the VA in identifying an appropriate acquisition strategy only. A solicitation package is not available at this time. Responses should be sent to christopehr.brailer@va.gov. No telephone responses will be accepted. See Salient Characteristics below. Background: The Malcom Randall VA Medical Center needs 2 new Baldor Chilled Water Motors. Objective: Purchase 2 new motors for the Ewing Chilled Water System. The new motors must be premium efficiency inverter duty rated motors. Salient Characteristics: Purchase 2 new custom Baldor Reliance vertically mounted 150 horsepower premium efficiency inverter duty rated motors. Frame - 444TC Rpm - 1780 OPD Class F insulation Volts - 230/460 Amps - 346/173 Hz - 60 Phase - 3 SF - 1.15 Nema eff 95%
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANFSGHS/DVANoFSoGHS/VA24814I0290/listing.html)
 
Document(s)
Attachment
 
File Name: VA248-14-I-0290 VA248-14-I-0290.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1130256&FileName=VA248-14-I-0290-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1130256&FileName=VA248-14-I-0290-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Malcom Randall VA Medical Center;1601 S.W. Archer Road;Gainesville, FL 32608-1197
Zip Code: 32608-1197
 
Record
SN03253744-W 20131219/131217235735-31c5682e3bef325e1202845434939cda (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.