MODIFICATION
38 -- ***Correction to CLIN 0001 Quantity, see amendment***Contractor shall provide (1) 1600 CFM or greater Air Compressor with after cooler for RENTAL from 16 Dec 13 through 14 March 14 with options to extend through 14 June 2014.
- Notice Date
- 9/6/2013
- Notice Type
- Modification/Amendment
- NAICS
- 532412
— Construction, Mining, and Forestry Machinery and Equipment Rental and Leasing
- Contracting Office
- USACE District, St. Paul, Contracting Division CEMVP-CT, 180 East Fifth Street, St. Paul, MN 55101-1678
- ZIP Code
- 55101-1678
- Solicitation Number
- W912ES-13-T-0114
- Response Due
- 9/11/2013
- Archive Date
- 11/5/2013
- Point of Contact
- Gwendolyn Davis, 651-290-5723
- E-Mail Address
-
USACE District, St. Paul
(gwendolyn.k.davis@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- ***Correction to CLIN 0001 Quantity, see amendment*** This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Please read Scope of Work and Notes to Offerors in Solicitation. 1.) Contractor shall provide (1) 1600 CFM or greater Air Compressor with after cooler on 16 Dec 13 through 14 March 14. The price for this unit shall include delivery, setup, test run and operational training. Hours for delivery and pick-up must be between 8:00 AM and 3:00 PM. No deliveries will be received on holidays or weekends. 2.) The compressor may be needed from 14 March 14 through 13 June 14. This time is set up in 1 month options to the original contract to be used if necessary. 3.) Upon delivery to Lock and Dam 8, contractor must test run the air compressor. In addition, the contractor must conduct operational training to the Lock and Dam 8 Dewatering Project personnel. 4.) The compressor unit must have a block heater system to be able to operate in the cold temperatures. Glow plug system will not permitted, must be block heater. 5.) The compressor will run an average of 10 hours per day. The contractor must provide 24 hour service support and be able to respond with two hours of a reported problem. This compressor will be used on the night shift so the reported problem would likely happen between 10:00 PM and 06:00 AM.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA37/W912ES-13-T-0114/listing.html)
- Place of Performance
- Address: USACE District, St. Paul Contracting Division CEMVP-CT, 180 East Fifth Street St. Paul MN
- Zip Code: 55101-1678
- Zip Code: 55101-1678
- Record
- SN03176929-W 20130908/130906235010-349df49de5d5f718bb389e96502f25c2 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |