- Description
- SCOPE OF WORK/SYNOPSIS 1. Project #: 534-12-110 2.Title: Correct Induction Units 5BS 3.Project Description: Provide the necessary labor, materials and supervision, testing and certification to remove the induction unit HVAC systems within the area of work. Remove the existing HVAC systems in rooms within the area of work that do not have induction units. Provide a packaged central rooftop air handling unit, with DDC, that will serve renovated space with chill water and hot water and VAV box. Demolish select walls, floor finishes, doors, flooring, and ceilings complete, including electrical, plumbing, and telecommunications. Construct new walls, infill walls, floor finishes, doors, windows, and ceiling. Construct new electrical and telecommunications system. Abate asbestos as required in the project. This project will be accomplished in multiple phases and time shall be allowed for VA staff to move out of each phase prior to construction beginning in each phase. Provide a new Class A fire alarm system complete with fire alarm devices, conduit, wire, control panels, and other required equipment as indicated on drawings and in specifications. Provide fire sprinkler system. Provide security system for doors in 3 locations. The areas of work are shown on the drawings which include all floors including a basement crawl space. Work includes, but is not limited to, removal, replacement, patching, repair, sealing, fire stopping of all materials affected by installation of new work. New addressable modules will be required, but not limited, for tamper switches, flow switches, and door closers/holders. Work will be phased throughout the duration of the project. Work in specific areas shall be scheduled other than 8 AM to 4 PM at the discretion of the contracting officer. The existing fire alarm system shall remain in operation and intact until the new fire alarm system is tested and certified in writing by the fire alarm manufacturer. The existing fire alarm system shall undergo demolition after the new fire alarm system is tested and certified. 4.Completion all work within 540 days from the notice to proceed. This is a Total Service-Disabled Veteran-Owned Small Business Set-Aside requirement. Interested firms must be registered in SAMS at https://www.sam.gov. SAMS includes the CCR and ORCA registration. Firms must also be visible in the VIP pages at http://www.vip.vetbiz.gov. IF YOU ARE NOT LISTED IN SAMS AND THE VIP PAGES, YOU WILL NOT BE ELIGIBLE TO SUBMIT A BID. The estimated construction cost is between $2,000,000 and $5,000,000. The NAICS Code is 238220 and the SBA size standard is $14 Million. The IFB is tentatively scheduled to be released on or about September 9, 2013. THE SOLICITATION INCLUDES A BASE BID ITEM AND FOUR (4) BID DEDUCT ITEMS AS DESCRIBED ON THE ATTACHED STATEMENT OF BID ITEM(S).
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ChaVAMC/VAMCCO80220/VA24713B1407/listing.html)
- Document(s)
- Attachment
- File Name: VA247-13-B-1407 VA247-13-B-1407_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=975680&FileName=VA247-13-B-1407-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=975680&FileName=VA247-13-B-1407-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA247-13-B-1407 VA247-13-B-1407_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=975680&FileName=VA247-13-B-1407-000.docx)
- Place of Performance
- Address: 109 BEE STREET;CHARLESTON, SC
- Zip Code: 29401-5799
- Zip Code: 29401-5799
- Record
- SN03165913-W 20130830/130829000020-5f2a94635059c5920afe182af18689ab (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |