44 -- Facilities - Burner See Attached Synopsis of Work This RFI is issued solely for information and planning purposes and is not a solicitation. - Attachment
- Notice Date
- 8/22/2013
- Notice Type
- Attachment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;Philadelphia VAMC;Acquisitions;3900 Woodland Avenue;Philadelphia PA 19104-4551
- ZIP Code
- 19104-4551
- Solicitation Number
- VA24413Q1599
- Response Due
- 8/29/2013
- Archive Date
- 8/30/2013
- Point of Contact
- Frederick C Hilliard
- Small Business Set-Aside
- Total Small Business
- Description
- Boiler Plant - VA Medical Center, Philadelphia PA 191 04 STATEMENT OF WORK Burner #1 Replacement; 400 HP Cleaver Brook (CB) Boiler Provide labor and materials necessary for: 1)Remove the existing burner, forced draft fan, windbox, gas and fuel oil piping, as required to prepare Boiler 1for installation of the new burner, including removal of all power and control wiring and conduit. 2)Provide and install one new ProFire NTD168LGR-30S-6P dual fuel burner (natural gas & #2 fuel oil). 3)Provide and install one new 25 hp integral forced draft fan and AB Poerflex 400 variable frequency drive. 4)Provide and install one new natural gas train, complete with controls, valves, safeties, and piping. S)Provide and install one new fuel oil gas train, complete with controls, valves, safeties, and piping. 6)The existing propane backup pilot gas system to be reinstalled. 7)Provide one new Flue Gas Recirculation NEMA 4 servo, to mount on existing FGR control valve. Re-pipe FGR as required to mate to new burner arrangement. All FGR piping to be insulated, complete with aluminum jacket. 8)Provide and install one new atomizing air compressor, to match air compressors previously installed for Boilers 2, 3 & 4. 9)Provide and install new electric solenoid valves into air feed of opacity monitors located on each boiler stack. Each solenoid valve will be powered from its corresponding boiler control panel, to open when the boiler is operating, and closed when the boiler is secured. 10)All CB Burner material, specialties, air compressor, start-up and burner performance testing to be provided I performed by CB local representative. 11)CB local representative is Delval Equipment. 12)CB or their representative will provide technical assistance two (2) visits per week for the duration of the Burner, installation. Burners: Model No. ProFire NTD168LGR-30S-6P to include: oHawk ICS 5000 IWT Existing to be reused o25 HP TEFC XRI Premium Efficiency Motor o25 HP AB Power Flex 400 with Line reactor NEMA 4 with Bypass oIR Fiber Optic Kite to allow operator to reuse existing IR FSG in the field oStandard Burner Housing Arrangement oCodes: Non applicable, reuse existing gas train, existing controls. Burner components are UL oOil Servo Motor Mounted NEMA 4 o(2) BFV with Gas Servo Pinned and Mounted oFGR Servo NEMA 4 oAir Servo NEMA 4 oNEMA 4 Blast Tube Temp Switch oNEMA 4 Pilot Train Low Gas Pressure Switch o(2) Pilot Train Lubricated Plug Valves oPurge Air Pressure Switch oThermometer Oil Temp 50-300 F 2-1/2" Dial oOil Nozzle Customer to reuse existing oil pump system oOil Train to include (2) NEMA 4 Oil Valves Maxon with POC, NEMA 4 High Oil Pressure Switch, NEMA 4 Low Oil Pressure Switch. Low Atomizing Air Switch, Pressure Relief Valve, Oil Strainer, Regulating Relief Valve at Piping Inlet and (4) Test Cocks {Gauges) oAdditional Low Atomizing Air Switch oNT Atomizing Air Regulator Train Assembly for Plant Air oNEMA 4 J Box 12x12x6 oCB Blue Paint oSubmittals {to include all manufacturers cut sheets, P&ID, special WD as required) oCustom Refractory Mounting Plate. To be built per field dimensions: oCharacteristics: oVoltage480 oPhase3 oCycles60 Notes: oControls oGas Pressure oGas Pressure required at the manifold oFGR oMain Gas Connection oFGR Connection 120 volt 10 Psi to Inlet of Reg 4 Psi 8" Right left 1)The NTD series burner is gun style and will require a support or platform to be built underneath of it. 2)Estimated Up to 5-1Turndown on Gas 3)CB Package burner include CB blue paint (must be provided) 4)Gas pressure gauges, T connections and vent lines, lockable plug valves by others, (2) gas POC override and oil POC override on panel not recommended. Existing to be modified 5)<30 PPM NOx on natural gas. <90 PPM NOx on oil (Fuel bound nitrogen not to exceed 0.015% by weight. Furnace back pressure not to exceed 4n we.) CO <200 PPM at 5-1 Turndown 6)Minimal Factory test (spin and balance motor, check point to point electrical) due to no factory panel and no factory gas train 7)4 PSI gas pressure required at boiler manifold 8)Compressor included in this Contract 9)Electronic submittal copies are standard 10)No asbestos abatement is needed in the Contract 11)Warranty will be 18 months from the date of shipment or 1year from the date of acceptance by the VA For NT Burners, the following FGR parameters must be followed: 1)Furnace draft at FGR take off to be controlled within -0.25"wc. and +o.25"wc. with FGR damper 2)FGR ducting to be insulated to temperatures between 325 ° - 575 °F 3)FGR ducting Op to be kept below 0.15" with FGR damper 4)Water trap to be installed upstream of burner FGR metering Valve END
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC642/PhVAMC642/VA24413Q1599/listing.html)
- Document(s)
- Attachment
- File Name: VA244-13-Q-1599 VA244-13-Q-1599.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=964371&FileName=VA244-13-Q-1599-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=964371&FileName=VA244-13-Q-1599-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA244-13-Q-1599 VA244-13-Q-1599.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=964371&FileName=VA244-13-Q-1599-000.docx)
- Place of Performance
- Address: Philadelphia VA Medical Center;3900 Woodland Ave;Philadelphia, PA
- Zip Code: 19104-4551
- Zip Code: 19104-4551
- Record
- SN03158540-W 20130824/130822235616-b194629ad4ad5e73b2854ec2b93778ca (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |