MODIFICATION
58 -- Gen Sets for Future FMS Cases
- Notice Date
- 8/16/2013
- Notice Type
- Modification/Amendment
- Contracting Office
- ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
- ZIP Code
- 21005-1846
- Solicitation Number
- MARKET-SURVEY-5497-1
- Response Due
- 9/16/2013
- Archive Date
- 10/15/2013
- Point of Contact
- Tineka C. Davis, 443-861-5439
- E-Mail Address
-
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- FOR MORE INFORMATION PLEASE CONTACT: Mitch Jacquay 443-861-5671 mitchell.a.jacquay.civ@mail.mil, Franklin Lee 443-861-5657 franklin.f.lee.ctr@mail.mil, Tony Blais 443-861-5672 anthony.w.blais.civ@mail.mil This Market Survey is for suppliers or actual manufacturers for skid mounted, (available with wheel set option for low power output applications) 24 VDC, 50 and 60 Hz Generators in various outputs ranging from 2 to10 kW. Survey is revised to clarify requirements. FOR MORE INFORMATION PLEASE CONTACT Mitch Jacquay, EMAIL mitchell.a.jacquay.civ@mail.mil, Franklin Lee, EMAIL franklin.f.lee.ctr@mail.mil, Tony Blais EMAIL anthony.w.blais.civ@mail.mil **You must respond NO LATER than the Respond Date and Time ACC-APG-C4ISR intends to acquire the following Gen Sets utilizing a multiyear contract to satisfy existing and future FMS acquisitions: 2, 3 kW 50Hz Generators 2, 3 kW 60Hz Generators 2, 3 kW 24-28 VDC Generators 5kW 50Hz Generators 5kW 60Hz Generators 8-10kW 50Hz Generators 8-10kW 60Hz Generators. Acquisition of the above may also require the procurement of spares parts needed for maintenance and operator level training at country's location. 1. A quality system similar to ISO-9001for monitoring all phases of manufacturing will be requested after contract award. 2. Require no longer than one year delivery from date of award. 3. Identify whether you are a small or large business 4. If you are a small business then identify your subcategory, i.e. 8A, SDB, SDVOB, etc. Gen Set Requirements are as follows: 2,3 kW, 60Hz, 120 VAC, Single Phase, 2 Wire, NEMA 5-15, 120 VAC (GFCI)/NEMA 5-20R (GFCI) Receptacles. 2,3 kW, 50Hz, 120 VAC, Single Phase, 2 Wire, Receptacles specified on Delivery Order. 2,3 kW, Rectified for 28 VDC, No Receptacles, (+/- Lugs). 5 kW, 60 Hz, 120/240, Single Phase, 2 Wire & Single Phase, 3 Wire, NEMA 5-20R (GFCI), NEMA 6-15R Receptacles. 5 kW, 50 Hz, 120/240, Single Phase, 2 Wire & Single Phase, Receptacles specified on Delivery Order. 8-10 kW, 60, 120/240 Single Phase, 2 Wire, Single Phase 3 Wire and Three Phase, 4Wire, NEMA 5-20R (GFCI), NEMA 6-15R, NEMA 6-20R, NEMA 15-15R, NEMA 18-20R Receptacles. 8-10 kW, 60, 120/240 Single Phase, 2 Wire, Single Phase 3 Wire and Three Phase, 4Wire, Receptacles specified on Delivery Order. Other Requirements: Diesel Powered, (Liquid Cooled for 8-10kW power output range) Minimum 6 hour run time till empty Brushless Alternator Skid Mounted Minimum one year warranty Performance Specs: Frequency Accuracy:.8% Voltage Accuracy: +/-6% Respond to My Attention by COB Eastern on 16 Sep 2013 Mitchell Jacquay, Email mitchell.a.jacquay.civ@mail.mil, Franklin Lee, Email franklin.f.lee.ctr@mail.mil, Tony Blais, Email anthony.w.blais.civ@mail.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/19b301b12486d31d6b90048a60363653)
- Place of Performance
- Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
- Zip Code: 21005-1846
- Zip Code: 21005-1846
- Record
- SN03152644-W 20130818/130816235337-19b301b12486d31d6b90048a60363653 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |