Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 03, 2013 FBO #4270
SOLICITATION NOTICE

66 -- Presolicitation for a fully integrated Frontier EGA/PY-3030D Multi-Shot Pyrolyzer Agilent 7890B Gas Chromatograph Agilent 5977 A Mass Spectrometer (MS)system (PY-GC-MS) to support evolved gas analysis and traditional material analysis.

Notice Date
8/1/2013
 
Notice Type
Presolicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
ACC-RSA - (Missile), ATTN: CCAM, Building 5303, Martin Road, Redstone Arsenal, AL 35898-5280
 
ZIP Code
35898-5280
 
Solicitation Number
W31P4Q-13-T-0171
 
Response Due
8/30/2013
 
Archive Date
9/30/2013
 
Point of Contact
Angela Harris, 2568423303
 
E-Mail Address
ACC-RSA - (Missile)
(angela.m.harris.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
THIS IS A PRE-SOLICITATION NOTICE, OTHERWISE KNOWN AS A SYNOPSIS (SUMMARY). THE SOLICITATION PERTAINING TO THIS NOTICE WILL NOT BE AVAILABLE UNTIL APPROXIMATELY 15 DAYS FROM THE DATE OF THIS NOTICE. The US Army Contracting Command Redstone has a requirement for the acquisition of one (1) each fully integrated Pyrolyzer (PY)-Gas Chromatograph (GC)-Mass Spectrometer (MS) system from Quantum Analytics of Foster City, CA 94404-1101. Quantum Analytics is the only company found that can provide the fully integrated turn-key PY-GC-MS system as is required to meet the needs of AMRDEC. The Agilent 5977A MS is required as it must be compatible with an existing Agilent 5975C MS chemical ionization source that is available for use within the AMRDEC and must provide the 1500:1 signal-to-noise ratio that meets the sensitivity needs of AMRDEC. The Frontier EGA/PY-3030D is required as it is the only micro-furnace pyrolyzer that provides heating conditions equivalent to an existing TA Instruments Q500 TGA for direct comparison with weight loss thermogram data, has no external transfer line to the GC, and provides an option for upgrade to include a Micro Ultraviolet (UV) Irradiator. The Agilent 7890B GC is required as it must be fully compatible with the Agilent 5977A MS and run via a single GC-MS software for seamless experimental programming. In addition, the Agilent 7890B GC has the necessary dual inlets to provide sampling from the traditional injection method as well as directly from the pyrolyzer without reconfiguration. All three instruments must be fully compatible and integrated with software cross-talk to allow for a single-point-start experiment from either sample introduction method. Solicitation number W31P4Q-13-T-0171 is to be a firm fixed price acquisition, in accordance with FAR Part 13.106-1 (a). The corresponding NAICS code for this procurement is 334516. CLIN 0001 will be issued for one (1) each fully integrated Pyrolyzer (PY)-Gas Chromatograph (GC)-Mass Spectrometer (MS) system. All responsible concerns may submit a quotation which shall be considered by the agency. Contract award is anticipated on or about 9 September, 2013. Oral communications are not acceptable in response to this notice. Email response is preferred; point of contact for further information is Angela.M.Harris.civ@mail.mil or via facsimile at 256-313-2392, marked to the attention of Angela Harris.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/7244d3904a09ca30a1e3903044f72771)
 
Place of Performance
Address: ACC-RSA - (Missile) ATTN: CCAM-RD-D, Building 5400, Fowler Road Redstone Arsenal AL
Zip Code: 35898-5280
 
Record
SN03134224-W 20130803/130801235511-7244d3904a09ca30a1e3903044f72771 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.