Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 04, 2013 FBO #4149
SOURCES SOUGHT

66 -- Signal Conditioner, 8 ch, ICP charge sensor.

Notice Date
4/2/2013
 
Notice Type
Sources Sought
 
NAICS
334419 — Other Electronic Component Manufacturing
 
Contracting Office
MICC - Dugway Proving Ground, Division of Contracting, Building 5330 Valdez Circle, Dugway, UT 84022-5000
 
ZIP Code
84022-5000
 
Solicitation Number
0010322027
 
Response Due
4/9/2013
 
Archive Date
6/1/2013
 
Point of Contact
Patricia S Natividad, 435-831-3429
 
E-Mail Address
MICC - Dugway Proving Ground
(patricia.s.natividad.civ@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
The U.S. Army Dugway Proving Ground Mission Installation Contracting Command is seeking sources that can provide Specifications for an 8 Channel Signal Conditioner ICP Charge Sensor. Specifications are as follows: Product Specifications: ENGLISHSI Performance Channels8 8 Sensor Input Type(s)ICP, Voltage, ChargeICP, Voltage, Charge Voltage Gain Increment0.1 0.1 Accuracy 5 % 5 % Accuracy 1 % 1 % Sensitivity ( 1 %)0.1-10.0 mV/pC0.1-10.0 mV/pC Low Frequency Response (-5 %) 0.05 Hz 0.05 Hz Low Frequency Response (-5 %)0.5 Hz0.5 Hz[3][4] High Frequency Response (-3 dB) greater than 100 kHz greater than 100 kHz High Frequency Response (-3 dB) greater than 80 kHz greater than 80 kHz Filter TypeLow PassLow Pass Electrical Filter Corner Frequency (-3 dB)10 kHz10 kHz[5] Electrical Filter Roll-off24 dB/octave24 dB/octave Electrical Filter Pass Band Amplitude Accuracy1 %1 % Phase Response 2 2 Non-Linearity1 %1 % Cross Talk less than 72 dB less than 72 dB TEDS Sensor SupportYesYes Fault/Bias Monitor/MeterOpen/Short/OverloadOpen/Short/Overload Control Interface Digital Control InterfaceEthernetEthernet Environmental Temperature Range+32 to +120 F0 to +50 C Electrical Power RequiredAC PowerAC Power AC Power100 to 240 VAC100 to 240 VAC AC Power 0.85 Amps 0.85 Amps Excitation Voltage (To Sensor) greater than 24 VDC greater than 24 VDC DC Offset less than 50 mV less than 50 mV Constant Current Excitation (To Sensor) (To Sensor )2 to 20 mA2 to 20 mA[2] Constant Current Excitation ( 0.6 mA)4 mA4 mA Output Voltage10 V10 V Output Current50 mA50 mA Output Impedance less than 50 Ohm less than 50 Ohm Overload Threshold ( 0.5 Vpk) 10 Vpk 10 Vpk Discharge Time Constant ( 25 %)1 sec1 sec Broadband Electrical Noise (1 to 10000 Hz)50 V/rms50 V/rms[1] Spectral Noise (1 Hz)8 V/ Hz8 V/ Hz[1] Spectral Noise (10 Hz)2 V/ Hz2 V/ Hz[1] Spectral Noise (100 Hz)0.7 V/ Hz0.7 V/ Hz[1] Spectral Noise (1 kHz)0.7 V/ Hz0.7 V/ Hz[1] Spectral Noise (10 kHz)0.6 V/ Hz0.6 V/ Hz[1] Broadband Electrical Noise (1 to 10000 kHz)75 V rms75 V rms[1] Spectral Noise (1 Hz)18 V/ Hz18 V/ Hz[1] Spectral Noise (10 Hz)1.5 V/ Hz1.5 V/ Hz[1] Spectral Noise (100 Hz)1.0 V/ Hz1.0 V/ Hz[1] Spectral Noise (1 kHz)1.0 V/ Hz1.0 V/ Hz[1] Spectral Noise (10 kHz)1.0 V/ Hz1.0 V/ Hz[1] Broadband Electrical Noise (1 to 10000 Hz)350 V rms350 V rms[1] Spectral Noise (1 Hz)100 V/ Hz100 V/ Hz[1] Spectral Noise (10 Hz)10 V/ Hz10 V/ Hz[1] Spectral Noise (100 Hz)6 V/ Hz6 V/ Hz[1] Spectral Noise (1 kHz)5 V/ Hz5 V/ Hz[1] Spectral Noise (10 kHz)5 V/ Hz5 V/ Hz[1] Broadband Electrical Noise (1 to 10000 Hz)52.0 V rms52.0 V rms[1] Spectral Noise (1 Hz)10.0 V/ Hz10.0 V/ Hz[1] Spectral Noise (10 Hz)1.5 V/ Hz1.5 V/ Hz[1] Spectral Noise (100 Hz)0.6 V/ Hz0.6 V/ Hz[1] Spectral Noise (1000 Hz)0.6 V/ Hz0.6 V/ Hz[1] Spectral Noise (10000 Hz)0.6 V/ Hz0.6 V/ Hz[1] Broadband Electrical Noise (1 to 10000 Hz)52.0 V rms52.0 V rms[1] Spectral Noise (1 Hz)14.0 V/ Hz14.0 V/ Hz[1] Spectral Noise (10 Hz)2.0 V/ Hz2.0 V/ Hz[1] Spectral Noise (100 Hz)0.7 V/ Hz0.7 V/ Hz[1] Spectral Noise (1000 Hz)0.7 V/ Hz0.7 V/ Hz[1] Spectral Noise (10000 Hz)0.7 V/ Hz0.7 V/ Hz[1] Broadband Electrical Noise (1 to 10000 Hz)56.0 V/rms56.0 V/rms[1] Spectral Noise (1 Hz)15.0 V/ Hz15.0 V/ Hz[1] Spectral Noise (10 Hz)2.0 V/ Hz2.0 V/ Hz[1] Spectral Noise (100 Hz)0.6 V/ Hz0.6 V/ Hz[1] Spectral Noise (1000 Hz)0.6 V/ Hz0.6 V/ Hz[1] Spectral Noise (10000 Hz)0.6 V/ Hz0.6 V/ Hz[1] Electrical IsolationIsolated/Non-isolated Isolated/Non-isolated Electrical IsolationIsolated/Non-isolated Isolated/Non-isolated Oscillator (+/- 2% )0.1 V pk 100/1000 Hz 0.1 V pk 100/1000 Hz Oscillator (+/- 2% )100 pC pk 100/1000 Hz 100 pC pk 100/1000 Hz External Calibration Input (+/- 1% )1 V/V 1 V/V External Calibration Input (+/- 1% )1000 pC/V 1000 pC/V Physical Electrical Connector (Input, sensor)BNC JackBNC Jack Electrical Connector (Output)BNC JackBNC Jack Electrical Connector10-32 Coaxial Jack10-32 Coaxial Jack Electrical ConnectorRJ45RJ45 Size - Height (nominal )1.75 in44.5 mm Size - Width (nominal )19 in482.6 mm Size - Depth (nominal )13.7 in348 mm Weight8 lb3.6 Kg All specifications are at room temperature unless otherwise specified. Contractor must adhere to Army Regulations; AR 525-13, Antiterrorism and AR 530-1, Operations Security as described in section 8. The requiring activity for this procurement is the West Desert Test Center, Instrumentation Department, DPG,UT. A determination on the contract type, mechanism for procuring the services, and possible set-aside will not be made by the Government until after the market research has been completed. No proposals are being requested or accepted under this synopsis. The anticipated North American Industry Classification System Code (NAICS) for this requirement is 334419 and the size standard is 500. Qualified companies are encouraged to respond. Responses should provide the following information in response to this sources sought announcement: (1) business name and address; (2) name of company representative and their business title; (3) pertinent details and experience of doing this type of services (identify any relationship with work conducted with the Government s chemical and biological programs); (4) business size as it relates to the NAICS code and size standard stated in this sources sought announcement; (5) contract types typically used for these types of services; and (6) other contract vehicles that would be available to the Government for the procurement of these services, to include General Service Administration (GSA) Federal Supply Schedules; and/or any other Department of Defense contracts. PROCEDURES: This Request For Information (RFI) is a required component of a complete and systematic process to evaluate interested parties in order to minimize cost both to potentially interested parties and the Government. Interested sources are also encouraged to submit product literature in response to this Request for Information (RFI). Any submission of such product literature or catalog cut sheets will be treated separate from, and will have no bearing on, any subsequent evaluation of proposals submitted in response to any resulting future formal Request for Quote. Interested parties should provide a statement of interest on company letterhead (not to exceed 20 pages in length) to: U.S. Army, Dugway Proving Ground, Attn: CCMI-CHD-DPG (Patricia Natividad), 5330 Valdez Circle, Bldg 5330 MS#1, Dugway Proving Ground, Dugway, Utah 84022-5000. No basis for claim against the Government shall arise as a result of a response to this SOURCES SOUGHT or Government use of any information provided. Elaborate proposals or pricing information are neither required nor desired. Any innovative and new conceptual ideas to achieve the stated objective are encouraged. No solicitation document exists for this request for Sources Sought. This notice is for informational purposes only; it is not a request for proposals nor should it be construed as a commitment by the Government. The Government will not pay for any effort expended into responding to this sources sought announcement. Responses must be submitted no later than 9:00AM (Mountain Standard Time), 4/9/2013 via email (patricia.s.natividad.civ@mail.mil) (FAX 435-831-2085). The point of contact concerning this sources sought action is Patricia Natividad, Contract Specialist at (435) 831-3429, or email patricia.s.natividad.civ@mail.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/2b821395e984928d239da3bb27496e62)
 
Place of Performance
Address: MICC - Dugway Proving Ground Division of Contracting, Building 5330 Valdez Circle Dugway UT
Zip Code: 84022-5000
 
Record
SN03026083-W 20130404/130402234606-2b821395e984928d239da3bb27496e62 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.