Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 20, 2013 FBO #4134
DOCUMENT

46 -- Legionella Filters - Attachment

Notice Date
3/18/2013
 
Notice Type
Attachment
 
NAICS
221310 — Water Supply and Irrigation Systems
 
Contracting Office
Department of Veterans Affairs;Wilkes Barre VAMC;Acquisitions (049E);1111 E End Blvd;Wilkes Barre PA 18711-0030
 
ZIP Code
18711-0030
 
Solicitation Number
VA24413I0590
 
Response Due
3/27/2013
 
Archive Date
4/26/2013
 
Point of Contact
Mark Knorr
 
E-Mail Address
norr2@va.gov<br
 
Small Business Set-Aside
N/A
 
Description
THIS IS NOT A SOLICITATION FOR PROPOSALS OR QUOTES. THIS IS A SOURCES SOUGHT SYNOPSIS ONLY. This synopsis is being issued under the authority of FAR 15.201("Exchanges of information before receipt of proposals"). This Request for Information (RFI) is for the purpose of identifying Vendors and/or Contractors that are capable of providing, replacing and servicing point of use filters for the removal of legionella spp. from the domestic water supply at the Wilkes-Barre, Pennsylvania, VA Medical Center. Salient Characteristics of Filters: 1.The Vendor/Contractor shall be able to provide laboratory tests, certifications, verifications testing or other documentation of the following: "The filters shall be manufactured by a company which is primarily involved in the production of medical or laboratory grade products. "The filters shall be point-of-use, inline, replaceable and have a certified average service life greater that 1-month under expected usage rates-i.e., hospital showers, sinks and other fixtures. "The filters shall be specifically designed for medical use and patient care and shall be sterilized in accordance with ISO 11137-1, ISO 11137-2 and ISO 11137-3 (20006 or more current). "The filter housings shall contain a bacteriostatic additive designed to reduce microbial contamination and shall meet all requirements of United States Pharmacopoeia 88 (in vivo). "The filters shall be verified to retain Brevundimonas diminuta in laboratory liquid microbial challenge tests for validating 0.2 ?m sterilizing grade filters to a minimum of 107 CFU/cm2 using the principals of ASTM F838-05 and Health Industry Manufacturers Association (HIMA) Guidance. Service: 1. The Vendor/Contractor shall be able to provide service or replacement of filters according to the certified usage rates under an annual Contract. Response: All Vendors/ Contractors are asked to reply to this Sources Sought RFI. However, please indicate in your response if you are a service-disabled veteran-owned small businesses (SDVOSB) that is registered in VetBiz. Please reply to Mark Knorr, Contract Specialist, Mark.Knorr2@va.gov with the following by the 4:30PM EST Wednesday, March 27, 2013: "Company Name "Point of Contact "Address "Phone "Email "Socio-Economic Status "A statement verifying that the product and you company meet all of the above requirements.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/WBVAMC693/WBVAMC693/VA24413I0590/listing.html)
 
Document(s)
Attachment
 
File Name: VA244-13-I-0590 VA244-13-I-0590 SRC.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=662207&FileName=VA244-13-I-0590-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=662207&FileName=VA244-13-I-0590-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Wilkes-Barre VA Medical Center;1111 East End Boulevard;Wilkes-Barre, PA
Zip Code: 18711
 
Record
SN03014404-W 20130320/130318235135-4afd3eb9f53dcd640e09b5139762c0a8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers