SOURCES SOUGHT
C -- Architecture-Engineering (A/E) Services For HVAC Renovations
- Notice Date
- 3/8/2013
- Notice Type
- Sources Sought
- NAICS
- 541330
— Engineering Services
- Contracting Office
- Department of Agriculture, Forest Service, Northern Research Station, 1992 Folwell Avenue -, Acquisition Management, St. Paul, Minnesota, 55108
- ZIP Code
- 55108
- Solicitation Number
- AG-63PX-S-12-0100
- Point of Contact
- Michael J. Ash, Phone: 6516495204
- E-Mail Address
-
mikeash@fs.fed.us
(mikeash@fs.fed.us)
- Small Business Set-Aside
- Total Small Business
- Description
- The U.S. Forest Service, Northern Research Station, has the need for architecture-engineering (A/E) services in fiscal year 2013 and requests that interested A/E's submit their SF-330's (Parts 1 & 2) to be considered. This is not a request for quotes. This is an opportunity for A/E's to exhibit their desire to be considered and to illuminate their qualifications. The SF-330's can be mailed, emailed or fax to Attn: Mike Ash Mailing Address: USDA Forest Service, NRS, 1992 Folwell Ave, St. Paul, MN 55108-1034 Email: Mikeash@fs.fed.us Fax: 651-649-5285 Northern Resesrch Station Morgantown, WV Main Building HVAC Renovations Phase III Design: estimated construction cost - $300,000 Location: Morgantown, WV Summary: Design the renovation and replacement of approximately 52 dual duct mixing boxes, associated ducting, actuators and dampers, 24 VAV boxes and ducting, hot water valves and controllers on three floors of a tee-shaped building. Create nine temperature control zones where none currently exist. Replace pneumatic control system with digital electrical controls. Install control sensors for each zone and thermostats in all rooms to allow nominal individual comfort adjustment. Install, program, test and certify DDC control/monitoring system for entire building. Background: This is a follow-up on work done previously. The major elements (cooling tower, boilers, air handlers and associated components) of the HVAC systems in the Morgantown office/lab were replaced in 2001. A 20-ton rooftop chiller/compressor was replaced in 2005. The total system must be analyzed & designed to provide greatest efficiency in energy usage and improved comfort to the building occupants. The final phase to complete this system consists of the design and resizing of the system's ductwork, the replacement/upgrade of the mixing boxes and VAV boxes, and the addition of a Direct Digital Control (DDC) system. The existing air movement system, aside from the major mechanical components, is over 50 years old.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USDA/FS/63PX/AG-63PX-S-12-0100/listing.html)
- Place of Performance
- Address: Forestry Sciences Laboratory, 180 Canfield St., Morgantown, West Virginia, 26504, United States
- Zip Code: 26504
- Zip Code: 26504
- Record
- SN03007793-W 20130310/130308234705-5e45b60992b47b4ac79c6d974a7280bb (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)