SOLICITATION NOTICE
66 -- Flowmeters, Sensor, and Displays
- Notice Date
- 3/4/2013
- Notice Type
- Presolicitation
- NAICS
- 334514
— Totalizing Fluid Meter and Counting Device Manufacturing
- Contracting Office
- USACE District, Portland, Contracting Division (CECT-NWP), P.O. Box 2946, Portland, OR 97208-2946
- ZIP Code
- 97208-2946
- Solicitation Number
- W9127N-13-Q-0019
- Response Due
- 3/8/2013
- Archive Date
- 5/3/2013
- Point of Contact
- ROSE CAUGHIE, (503) 808-4627
- E-Mail Address
-
USACE District, Portland
(rose.m.caughie@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- 15 EA Flowmeters shall be of the positive displacement type (Flow Technology's DC120 or an approved equal). Line size is two (2) inch diameter. 2 EA Fish unit flow meters shall be the positive displacement type (Flow Technology's DC120 or an approved equal). Line size is one and a half (1.5) inch diameters. 17 EA Hall effect senor with a minimum of 30 feet of cable. 17 EA Field mount rate and total display (Flow Technology's BR30 or an approved equal). Freight cost FOB Destination to Bonneville Lock and Dam, Interstate 84 Exit 40, Cascade Locks, OR 97014-0150. A delivery timeframe is required. Specification for Lubrication Oil Totalizers 1. Flowmeter: Flowmeters shall be of the positive displacement type (Flow Technology's DCI20 or approved equal.) Quantity: 17 Fluid: Shell T68 oil and Mobil DTE Heavy Shell T68 Viscosity @40degC: 65 eSt Mobil DTE Heavy @40 degC: 95 eSt Fluid Cleanliness Level per ISO 4406: 17/16/13 Line Size: 2 inch diameter (quantity 15) and 1.5 inch diameter (quantity 2). Connection: 2 inch diameter, 150# Flange (quantity 15) and 1.5 inch diameter, 150# flange (quantity 2). Flow Rate: 10 to 50 gpm Pressure: maximum of 150 psi Pressure drop across flowmeter: No larger than 5 psi at 20 gpm, or 13 psi at 50 gpm. Repeatability: +/- 0.05% of rate Resolution: 0.1Gallons Impeller: The impeller shall be of an appropriate material and style to deal with the fluid and cleanliness level. Sensor: Hall Effect with a minimum of 30 feet of cable 2.Field Mount Rate and Total Display: Flow Technology's BR30 or approved equal. Quantity: 17 Display: Both rate and total volume Power: Battery (lithium) Enclosure: NEMA 4X Input: Magnetic Pickup, or DC Pulse 3. Calibration: Flowmeter and Display shall be calibrated and programmed prior to shipment. 6 units shall be calibrated for use with Shell T68 turbine oil, and 11units (including the two 1.5 inch diameter units) shall be calibrated for use with Mobil DTE Heavy.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA57/W9127N-13-Q-0019/listing.html)
- Place of Performance
- Address: USACE District, Portland Contracting Division (CECT-NWP), P.O. Box 2946 Portland OR
- Zip Code: 97208-2946
- Zip Code: 97208-2946
- Record
- SN03002487-W 20130306/130305113756-f3e6b80160f864541f66b4514d9c8f92 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |