SOURCES SOUGHT
58 -- FMS Case JO-B-WBW
- Notice Date
- 12/14/2012
- Notice Type
- Sources Sought
- Contracting Office
- ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
- ZIP Code
- 21005-1846
- Solicitation Number
- MARKET-SURVEY-5369-1
- Response Due
- 1/4/2013
- Archive Date
- 2/12/2013
- Point of Contact
- Tineka C. Davis, 443-861-5437
- E-Mail Address
-
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- FOR MORE INFORMATON PLEASE CONTACT: Mitch Jacquay 443-861-5671 mitchell.a.jacquay.civ@mail.mil, Franklin Lee 443-861-5667 franklin.f.lee.ctr@mail.mil, Anthony Blais 443-861-5672 Anthony.w.blais.civ@mail.mil You must respond NO LATER than the Respond Date and Time The ACC-APG -C4ISR intends to acquire the following: -1. Provides for VDR-2 Radiac Set. Technical Characteristics: FEATURES PRE-SETTABLE AUDIBLE AND VISUAL: Dose and dose alarms. SETUP TIME: For all checks and alarms less than 1 min. ACCURACY: 15 %. CIRCUIT PROTECTION: AN/VDR-2 is nuclear and EMP hardened. EMI COMPATIBILITY: Will not be effected, or cause other equipment to be effected by its use. OPERABLE AND READABLE: By persons wearing Arctic and MOPP protective clothing. WEIGHT: 1.73 kg (3.8 lb). VOLUME: 909 cc (58 cubic in.). DIMENSIONS: 18.2 x 10.4 x 4.8 cm (7.2 x 4.1 x 1.9 in.). DETECTORS Two GM Tubes. GAMMA RADIATION: 0.001 Gy/hr to 999 cGy/hr (dose rate) and 0.001 Gy to 999 cGy (total dose). ENERGY RESPONSE: 20% 80 keV to 3 MeV. DOSE RATE: Minimum detectable level 0.1 Gy/hr. RESPONSE TIME: Within 10% of final reading in four seconds at 1.0 cGy/hr, returns to background within four seconds. DISPLAY An auto ranging LCD can be read at 3 ft, back lit for night use, updated every two seconds. Provides dose and dose rate readout in units of Gy, cGy, Gy, Gy/hr, cGy/hr and Gy/hr. Other readout units available on request Rads or Sieverts TOTAL (CUMULATIVE) DOSE READ OUT: Will not be erased when read, resettable to zero as desired. ALARMS Has selectable Visual and Audible indicators for day or night use. Alarm levels are settable over entire dynamic range. POWER Three 9 V batteries. Minimum battery life of 150 hr of continuous monitoring. Low battery LCD indication with 5 hr of battery life remaining, a Go/No Go feature provides battery status. RELIABILITY AND MAINTAINABILITY MEAN TIME BETWEEN FAILURE (MTBF): Greater than 2000 hr. MEAN TIME TO REPAIR (MTTR): 15 min. ENVIRONMENTAL PARAMETERS OPERATING TEMPERATURE: -51 C to +50 C (-59.8 F to 122 F). STORAGE/TRANSPORT TEMPERATURE: -60 C to +70 C (-76 F to 158 F). HUMIDITY: 0-100%. IMMERSION: 3 ft for at least 2 hr. SAND/DUST: Operates in winds to 1750 ft/min with exposure to fine dust and to 5700 ft/min to sand particles. FUNGUS: Built from inherently fungus resistant materials. VIBRATION AND SHOCK: Withstands vibration associated with transport and shocks of dropping in use. ALTITUDE: 12 192 m (40 000 ft). EXPLOSIVE ATMOSPHERES: Will not cause ignition of explosive gas mixtures -2. Provides for UDR-14 Pocket Radiac Set. Technical Characteristics: SYSTEM CHARACTERISTICS Features PRE-Settable Audible & Visual: Dose and Dose Rate Alarms Setup Time: Less than one minute for all checks and alarms Accuracy: 15% Enhanced Battery Life: Sleep mode provides 1500hrs battery life Circuit Protection: UDR-14 nuclear & EMP hardened EMI Compatibility: will not be effected or cause other equipment to be effected by its use Operable and Readable: by persons wearing Arctic & MOPP protective clothing Weight: 9.5 oz. (172 g) Volume: 10.5 in (172 cc) Dimensions: 100mm x 66mm x 28mm (3.875in x 2.50in x 1.25in) Detectors Pin Diode (neutrons), PMOS-FET (prompt gammas) & GM detector (residual gammas) Separate detectors for neutrons & gammas are combined to provide a single dose reading Reads In Tissue: dose centigray ( Gy), (Rads or Sieverts) available GAMMA Dose Rate: independent to 108 Gy/s NEUTRON dose Rate: independent to 1018 Gy/s GAMMA Energy Dependence: 20% 80keV to 3MeV Neutron Energy: Thermal to 14 MeV Total (Cumulative) Dose Read Out: will not be erased when read, resettable to zero as desired Dose Rate: minimum detectable level 0.2 Gy/hr Response Time: within 10% of final reading in four seconds at 1.0 Gy/hr returns to background within four seconds. Display Auto ranging LCD that can be read at 3 ft. back lit for night use, updated every two second. Data downloadable via optical (IR) communications port. Provide dose & dose rate readout in unit of: Gy, Gy, Gy, Gy/hr, Gy/hr & Gy/hr. Total (Cumulative) dose read out: will not be erased when read, resettable to 0. Alarms Selectable Visual & Audible indicators for day or night use. Alarm levels are settable over entire dynamic range. Power Four (4) AAA 1.5Volt batteries Minimum battery life of 150 hrs. during continuous monitoring and 1500hrs. during inactive (sleep) mode. Low battery LCD indication with 5hrs of battery life remaining a quote mark Go/No Go quote mark feature provide battery status. Environmental Parameters Operating Temperature: -50 C to +50 C (-59.8 F to 122 F) Storage/Transport Temperature: -60 C to +70 C (-76 F to 158 F) Humidity: 0-100% Immersion: 3ft for at least 2hrs Sand/Dust: operate in wind to 1750ft/min with exposure to fine dust & to 5700ft/min to sand particles Fungus: fungus resistant materials Vibration & Shock: withstands vibration associated with transport & shock of dropping in use. Altitude: 12192m (40,000ft) Explosive Atmospheres: will not cause ignition of explosive gas mixtures. REQUIRED INFORMATION: 1.If you are a reseller/distributor you MUST disclose the manufacturer of ALL ITEMS listed. 2.Please furnish price quotes for lot sizes. 3.You MUST reference the FMS case designator on your formal solicitations. 4.A quality system to monitor a phases of manufacturing will be requested after contract award. 5.Identify whether you are a small or large business 6.If you are a small business then identify your subcategory, i.e. 8A, SDB, SDVOB, etc. Respond to My Attention by 11 AM Eastern 4 on January 2013 Mitch Jacquay, EMAIL mitchell.a.jacquay.civ@mail.mil, Franklin Lee, EMAIL franklin.f.lee.ctr@mail.mil, Anthony Blais, EMAIL Anthony.w.blais.civ@mail.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/49cda506f13d88cc64223073561e415b)
- Place of Performance
- Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
- Zip Code: 21005-1846
- Zip Code: 21005-1846
- Record
- SN02949633-W 20121216/121214234707-49cda506f13d88cc64223073561e415b (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |