MODIFICATION
J -- ISOTROL SYSTEM RICHMOND ER ROOMS
- Notice Date
- 12/10/2012
- Notice Type
- Modification/Amendment
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
- ZIP Code
- 23667
- Solicitation Number
- VA24613Q0320
- Response Due
- 12/13/2012
- Archive Date
- 3/22/2013
- Point of Contact
- Leah Trossen
- E-Mail Address
-
8-7152<br
- Small Business Set-Aside
- N/A
- Description
- This is an amendment to the Combined Synopsis Solicitation Number VA246-13-Q-0320. Preventative Maintenance and repair of the Richmond VAMC Isotrol system. In section VI. Line item (2) Emergency Room; these panels have been removed and will not be tested. Statement of Work (SOW) will now read: I.The Contractor shall provide any on-site maintenance and repair services necessary to maintain the Isotrol electrical systems in a first class operating condition. Engineering Service will coordinate and schedule maintenance. Contractor personnel will check in and out with Engineering Service. The Contractor will test and repair electrical systems (Isotrol) in the following areas in a six (6) month interval: (1) Operating Rooms - Nine (9): (2) Recovery Room; (3) EP Lab (4A-105); (4) SICU; (6) MICU; (5) CCU; (6) Lower Level Research: (7) X-ray (1G-148/1G-149): (8) Cardiac Catherization Lab (1G-225). A. This series of tests will include all electrical devices in the designated areas. B. The testing will done "on location" and the results of any dangerous situations immediately given the institution. A full report will be provided within two (2) weeks. C. Each room and isolation systems will be tested for the following: (1) System voltage; (2) System leakage; (3) Panel leakage; (4) Conduit and wiring system leakage; (5) Ground detector or LIM trip levels. Comments and recommendations will be noted on each system. Each system will be checked to observe and not equipment problems as listed in the following: Sensing devices, GD/LIM display equipment, remote indicating equipment, power receptacles, surgical light fixtures, r-ray film viewer fixtures, and miscellaneous items (panels, lights, cords, etc.). A Complete grounding check will be performed and a reading listed in OHMS. Any problems will be noted. Appropriate room locations will be noted. An explanation of test report documentation will be provided. Contractor will notify the facility ten (10) working days in advance to assist in making spares available. Work must be performed during "off" hours so as not to interfere with the normal operating schedule (Monday through Friday, excluding holidays, 8:00 AM - 4:30 PM,). Contractor will adhere to all required safety and hygiene rules in the designated areas. Upon completion of each visit, a service ticket will be prepared by the contractor describing work done, results of tests performed, etc. The medical center employee who has witnessed the service will sign this service ticket. A copy of this customer signed service ticket must accompany each invoice submitted before payment will be authorized.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/VA24613Q0320/listing.html)
- Record
- SN02945620-W 20121212/121210234121-9dc36e360bafc8c08c7e189fd36fdf93 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |