Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 29, 2012 FBO #3962
SOURCES SOUGHT

Y -- ELECTRICAL CAPACITY AND COOLING TOWERS, BETHESDA, MARYLAND

Notice Date
9/27/2012
 
Notice Type
Sources Sought
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
N40080 NAVFAC WASHINGTON 1314 HARWOOD STREET Bldg 212 WASHINGTON, DC
 
ZIP Code
00000
 
Solicitation Number
N4008013R1101
 
Response Due
10/10/2012
 
Archive Date
10/25/2012
 
Point of Contact
NOLA CAMPBELL 202-685-3192
 
E-Mail Address
<!--
 
Small Business Set-Aside
N/A
 
Description
Electrical Capacity and Cooling Towers, Bethesda, Maryland The Department of the Navy, Naval Facilities Engineering Command (NAVFAC) Washington is seeking eligible Small Businesses, Small Disadvantaged Businesses, including 8(a) Certified, HUBZone Small Businesses, Women-Owned Small Businesses and Service Disabled Veteran-Owned Business firms, capable of performing the following: Demolishing the existing cooling towers and constructing new cooling tower cell(s) without service interruption to provide a total capacity of 52,000 GPM. In addition to the cooling towers, this project includes electrical work: constructing a 13.8kV electric underground duct bank based on PEPCO s requirement and integrating load shedding monitor control to the existing switchgears in the electrical vault. The work is to take place at Naval Station Activity Bethesda, MD. This is a DESIGN BUILD construction project. The magnitude of construction is between $25,000,000 and $100,000,000. Upon review of industry response to this Sources Sought Notice, the Government will determine whether a set-aside acquisition, in lieu of full and open competition is in the Government s best interest. The North American Industry Classification Standard (NAICS) Code is 238220, Plumbing, Heating, and Air Conditioning Contractors. The corresponding size standard is $14 million. Construction is estimated to start in MAR 2013 and end in SEP 2014. All identified small businesses are encouraged to respond to this Sources Sought Notice. Contractors are reminded that THIS SOURCES SOUGHT NOTICE IS NOT A REQUEST FOR PROPOSAL . It is a market research tool being used to determine the availability and adequacy of potential small business sources prior to determining the method of acquisition and issuance of an award. Responses to this Sources Sought Notice shall not constitute responses to the solicitation, which is not currently available. As stipulated in FAR 15.201, responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. The Sources Sought Notice is not to be construed as a commitment by the Government, nor will the Government pay for the information submitted in response. Respondents will not be notified of the results of any government assessments. The information received will be utilized to assist in formulating the acquisition. No proprietary, classified, confidential, or sensitive information should be included in your response. This documentation shall address, as a minimum, the following: (1) Relevant Experience of the Prime Contractor, for no less than three (3) projects, to include experience in performing efforts of similar size and scope that involved the installation of cooling towers, underground electrical ductbank, and load shedding monitor control within the last five (5) years, including contract number, indication of whether a prime or subcontractor, contract value, utility capacity, Government/Agency point of contract and current telephone number, and a brief description of how the contract referenced relates to the technical services described herein. (2) Company profile to include number of employees, office location(s), and statement regarding small business designation and status. (3) Statement regarding Bonding Capabilities. Provide single project and aggregate capabilities. Submissions must be received at the office cited no later than 2:00 PM Eastern Standard Time on 10 October 2012. The package shall be sent by mail to the following address: Naval Facilities Engineering Command, Washington, 1314 Harwood Street, SE, Building 212, Washington Navy Yard, Washington, DC 20374-5018 (Attn: Ms. Nola Campbell, Contract Specialist). If you have any questions or comments regarding this notice, please contact Ms. Campbell at (202) 685-3192 or via email at nola.campbell@navy.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62477/N4008013R1101/listing.html)
 
Place of Performance
Address: NAVAL STATION ACTIVITY, BETHESDA, MD
Zip Code: 20889
 
Record
SN02902265-W 20120929/120928000830-3353312402dc2c640422d8f8909c731b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |