SPECIAL NOTICE
30 -- 25 KW CUMMINS GENERATOR WITH I-WATCH CAPABILITY
- Notice Date
- 9/12/2012
- Notice Type
- Special Notice
- NAICS
- 335312
— Motor and Generator Manufacturing
- Contracting Office
- 124WG MSG/MSC, Boise Air Terminal, 4460 South Byrd ST, Boise, ID 83705-8092
- ZIP Code
- 83705-8092
- Solicitation Number
- W912J712T0101
- Archive Date
- 12/11/2012
- Point of Contact
- Tracy Stephens, 208-422-5270
- E-Mail Address
-
124WG MSG/MSC
(tracy.stephens@ang.af.mil)
- Small Business Set-Aside
- N/A
- Description
- The Idaho Air National Guard has a requirement to purchase a 25kw Spark Ignited Cummins Generator (PN 25GGMB) with options [listed below]. The Government has pre-existing Cummins Generators and this is adding to existing inventory. Further, all Cummins generators are running off of the Cummins I-Watch system. This software is proprietary to Cummins and is currently in use. This software gives members the ability to monitor, in real time, a generators performance and usage. Voltage and other vital engine readings can be remotely taken as required per AFI 32-1062 Sec. 6 operation & Attachment 2- A2.1.2 during operation. The Government intends to award a brand name contract for this requirement. The suggested contractor is Cummins Generator Corporation. The Government intends to solicit and negotiate only for the Cummins Brand name under Federal Acquisition Regulation 6.302-1 - No other supplies will satisfy agency requirements. This notice of intent is not a request for competitive proposals. Cummins Generator Corporation has been identified as the only current company approved by the 266 RANS to supply this equipment. However, any firm that believes they can provide the equipment listed below may submit a capability statement. Responses may be emailed to 124FW.MSCcontracting@ang.af.mil no later than 17 Sep 2012, at 9:00AM EST. This procurement will be prepared in accordance with FAR Part 8, Required Sources of Supplies and Services. CLIN 0001 - 25 KW Cummins Generator PN 25GGMB with options: Spark Ignited Genset: 60Hz-25kW Install-US-StatU.S. EPA, Stationary Emergency Application1 25GGMBGenset-Spark Ign,60Hz,25kW1 A331-2Duty Rating-Standby Power1 L090-2Listing-UL 22001 L156-2Cert-Seismic, IBC2000,2003,2006,Ss=3.41g.rooftop1 L164-2OSHPD Seismic Cert, Sds=2.28g1 L155-2EmissionsCert-SI,EPA,Emergency,Stationary,40CFR60 1 C099-2Fuel System-LP Vapor Withdrawal1 F217-2Enclosure-Aluminum, Sound Att,Level 2, w/Exh System1 R098-2Voltage-120/208,3 Phase,Wye,4 Wire1 B267-2Alternator-60Hz,12 Ld,Broad Rng,Full 1Ph Outp,125C1 H680-2SET CONTROL-PCC13011 B240-2Exciter/Regulator-Torque Match1 A366-2Engine Governor-Electronic, Isochronous Only1 H681-2Display-Control,LCD,NFPA110,CSA2821 K796-2Stop Switch-Emergency1 KS53-2Signals - Auxiliary, 8 Inputs/8 Outputs1 H608-2Control Mounting-Right Facing1 KP80-2Circuit Breaker Or Entrance Box-Right Side Only1 KT64-2CircuitBreaker-90A,Right,3P,600/525V,TM,80%UL/IEC1 F207-2Wind Rating-150MPH,Aluminum Housing1 F179-2Skidbase-Housing Ready1 A422-2Engine Starter - 12 VDC Motor1 A333-2Battery Charging Alternator-Normal Output1 E125-2Engine Cooling-High Ambient Air Temperature1 H389-2Shutdown-Low Coolant Level1 H036-2Coolant Heater-120 Volt Ac, Single Phase1 D041-2Engine Air Cleaner-Normal Duty1 L028-2Genset warranty- Base, Standby 2 years / 400 hours, Prime Power 1 year / unlimited hours, Continuous Power 1 year / unlimited hours1 L050-2Literature-English1 A322-2Packing-Skid, Poly Bag1 F065-2Rack-Battery1 H268-2Extension-Oil Drain1 CP01-2Common Parts Listing1 SPEC-CProduct Revision - C1 ManualsO&M Manuals3 BatteryLead acid batteries1 Transfer Switch-Power Command: 40A/70A/125A OTPC125Transfer Switch-Onan,PwrCmd,125 Amp1 A029-7Poles-41 A035-7Application-Utility To Genset1 A046-7Listing-UL 1008/CSA Certification1 A080-7Certification-Seismic ATS1 A044-7Frequency-60 Hertz1 A042-7System-3 Phase,3 Wire Or 4 Wire1 R021-7Voltage-208 Vac1 B002-7Cabinet-Type 3R1 C024-7Control-Transfer Switch, Level 21 M017-7Switch,Key,Front Panel Security1 M018-7Display-Digital1 M022-7Monitoring-Load1 M031-7Interface-Communications Network,FTT-101 KB59-7Battery Charger-15 Ampere, 12 Volt, 50/60 Hertz1 G010-7Transfer Switch Warranty - Yr 0-2: Parts, Labor and Travel; Yr 3-5: Parts Only; Yr 6-10: Main Contacts Only 1 CP01-7Common Parts Listing1 SPEC-AProduct Revision - A1 Communication Networking 0335-0215RS485 Cable-3 Pair Plenum - 100 Foot Spool3 0541-1302-01Remote Communication Interface Kit w/Modem (iWATCH100)1 UPS UPS for I-Watch 1 Delivery and set up will be required to ensure interface and connectivity with the software. Contracting Office Address: 124th Contracting, Boise, ID 83705 Point of Contact: Tracy Stephens Tracy.stephens@ang.af.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA10-1/W912J712T0101/listing.html)
- Record
- SN02880202-W 20120914/120913001800-a27c18cc445597a2056d83139a2c66e9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice