Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 06, 2012 FBO #3908
SOURCES SOUGHT

66 -- Optical Table - Drawings

Notice Date
8/4/2012
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFNWC/PKO - Kirtland (Operational Contracting Division), AFNWC/PKO Operational Contracting Division, 2000 Wyoming Blvd SE, Bldg 20604, Room B-9, Kirtland AFB, New Mexico, 87117-5606, United States
 
ZIP Code
87117-5606
 
Solicitation Number
F2KBAD2136A002
 
Archive Date
8/23/2012
 
Point of Contact
Bernadette N. Kerkhoff, Phone: 5058464670, Carl Landreneau, Phone: 505-846-4877
 
E-Mail Address
bernadette.kerkhoff@kirtland.af.mil, carl.landreneau@kirtland.af.mil
(bernadette.kerkhoff@kirtland.af.mil, carl.landreneau@kirtland.af.mil)
 
Small Business Set-Aside
N/A
 
Description
Drawings for the Optical Table This request is an announcement for information/market research for planning purposes. This synopsis does not constitute a request for proposal, request for quote, invitation for bid nor does its issuance, in any way, restrict the Government as to its ultimate acquisition approach. The Air Force Nuclear Weapons Center PKOA, Kirtland AFB, New Mexico is seeking potential sources to provide an Optical Table. CLIN 0001: 1 Each Optical Table General Requirements common to CLIN 0001 DESCRIPTION: High rigidity, temperature and vibration resistant optical table. 5ft x 14ft x18 inch (thick). Stainless steel top and bottom surfaces, 1/8" or thicker. Top surface tapped and drilled with ¼ inch-20 threaded holes on 1 inch center. Top and bottom surface of table reinforced with ½" steel rods drilled through and bolted/tapped to reduced possibility of table delamination under vibration conditions. Reinforcement rods should be on nominal 2 ft. centers for a total of at least 14 reinforcement rods. See attached picture for notional arrangement of reinforcement rods. Epoxy should be compatible with a -30F to 120F operating temperature range or greater. Table structure should be compatible with low amplitude (less than 2 inch total displacement) inertially induced vibration from 5-300 Hz or greater from a nominally level plane. Table structural support will be provided by purchaser in corners and center of table. (See Attachments) Firms responding to this announcement shall include company name, DUNS number, cage code, point of contact, address and business size using NAICS Code 334516, Size Standard 500 employees. Statement of Capabilities (SOCs), limited to 2 pages and shall demonstrate experience in providing or manufacturing of product or capability to provide products meeting the specifications listed. Statement of Capabilities may be submitted by facsimile at (505) 846-8925 Attn: Bernadette N. Kerkhoff or preferably via E-mail to: bernadette.kerkhoff@kirtland.af.mil.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/377CONSKOC/F2KBAD2136A002/listing.html)
 
Place of Performance
Address: Kirtland Airforce Base, Kirtland AFB, New Mexico, 87121, United States
Zip Code: 87121
 
Record
SN02827300-W 20120806/120804233431-d3b8d9b65a53305a166bb361db6d3f17 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.