SOLICITATION NOTICE
20 -- Initial In-Shop Inspections of Stern Tube Shafts and Propeller Shafts
- Notice Date
- 8/2/2012
- Notice Type
- Presolicitation
- NAICS
- 541330
— Engineering Services
- Contracting Office
- N65540 NAVAL SHIP SYSTEM ENGINEERING STATION, CARDEROCK DIVISION, PA Naval Surface Warfare Center Naval Business Center, Naval Base Philadelphia, PA
- ZIP Code
- 00000
- Solicitation Number
- N6554012T5236
- Response Due
- 9/3/2012
- Archive Date
- 9/30/2012
- Point of Contact
- Andrew Lucas 215-897-1232
- E-Mail Address
-
andrew.c.lucas@navy.mil
(andrew.c.lucas@navy.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- This synopsis/solicitation has been posted to both the Federal Business Opportunities (FBO) page located at http://wps.eps.gov and the Navy Electronic Commerce Online (NECO) site located at http://www.neco.navy.mil. Please feel free to use either site to access information posted by the Naval Sea Systems Command. The Naval Surface Warfare Center, Carderock Division, Philadelphia intends to procure services on a SMALL BUSINESS SET ASIDE BASIS to provide Initial In-Shop Inspections of Stern Tube Shafts and Propeller Shafts. Before inspection contractors must remove all covering, including GRP, fairing compound, and corrosion preventive paint/primer, as applicable, on the shaft body and sleeve end prep areas by mechanical means. Remove all residual preservative from the flanges as well as any corrosion preventive paint/primer. Remove all oil and/or grease from the shaft surfaces, including the bore. The Stern Tube Shaft and Propeller Shaft inspections shall include: Remove covering, including GRP, fairing compound, and corrosion preventive paint/primer. Remove all residual preservative from the flanges as well as any corrosion preventive paint/primer. Visually inspect the outer steel surfaces of the shaft for areas of rust/corrosion. Accomplish a visual inspection on the entire outer surface (shaft and sleeves), including spigots, counter bores, flange bolt holes, and o-ring sealing surfaces. Visually inspect the shaft bore for corrosion, pitting, scoring, and any other defects, especially in way of the valve rod guides. Accomplish a magnetic particle test (MT) or liquid penetrant test (PT). Accomplish a liquid penetrant test (PT). Contractor shall re-fiberglass shaft prior to re-packaging. This is a pre-solicitation and a full solicitation will be available for download on August 17, 2012. No questions will be taken until the full solicitation is released. Phone calls will NOT be accepted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVSEA/N00167/N6554012T5236/listing.html)
- Record
- SN02824728-W 20120804/120803000343-18e159bdf9fee974064a618c92d0c5a8 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |