Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 01, 2012 FBO #3903
DOCUMENT

49 -- Studio Robotic Heads Repair - Attachment

Notice Date
7/30/2012
 
Notice Type
Attachment
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of Veteran Affairs;SAO East;PCAE STL Contracting Officer;11152 South Towne Square;Saint Louis MO 63123
 
ZIP Code
63123
 
Solicitation Number
VA77712I0318
 
Response Due
8/6/2012
 
Archive Date
8/16/2012
 
Point of Contact
ANTHONY BALESTRERI
 
Small Business Set-Aside
N/A
 
Description
SOURCES SOUGHT DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. INSTRUCTIONS TO VENDORS: This is a request for information (RFI) purely for purposes of market research. If you feel you can meet this requirement, please send a capability statement demonstrating your qualifications to Anthony.Balestreri@va.gov. If you have any questions, please send them by email to Anthony.Balestreri@va.gov. All capability statements are due by August 6, 2012 by 3:00 PM EST. Repair Services for Robotic Camera Heads The purpose of this performance work statement (PWS) is to repair two existing robotic camera positioning systems that are an integral part of the Orad Virtual Set system used to support the VA Central Office Studio. The Mini Head Control (mHCU) unit is attached to the 436VR robotic camera positioning head system and supports the control interface between the RCP-2 (Remote Control Panel) and the robotic head. The mHCU provides continuous position information for pan, tilt, zoom and focus that is used by the Orad virtual set system to maintain the correct perspective and positioning of the 3D digital virtual sets that are created to support various VACO programs and live broadcasts. Due to voltage surges related to studio power problems that have been corrected, two of the mHCU systems have failed components that prevent head position telemetry to be relayed to the Orad HDVG media compositing system which is critical to the operation of virtual set system. Items and quantities are listed below: Item No. Model Description HK 185-098-0007-DBmHCUMini Head Control Unit HK 185-098-0007-DB mHCUMini Head Control Unit HK436-002-0001-DC436VRRobotic Camera Head Unit (failed SPI card) P/N HK-705-122-0002 DA with HK-705-123 Apex daughter card Task 10.1: Test and repair or replace SPI card for 436VR robotic head. Task 10.2: Replace failed components of the (2) mini head control units (mHCU) calibrate and bench test system to assure that they function within specifications. Deliverable 10.1: Repair or replacement SPI board and Apex daughter card and repair and test mHCU units for 436VR heads.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAAAC/VAAAC/VA77712I0318/listing.html)
 
Document(s)
Attachment
 
File Name: VA777-12-I-0318 VA777-12-I-0318_1.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=419973&FileName=VA777-12-I-0318-003.doc)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=419973&FileName=VA777-12-I-0318-003.doc

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02819630-W 20120801/120730235050-48f4bc8e5e5058983b83b7aa6dabc63c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.