SOURCES SOUGHT
79 -- Parts Washer Including Chemicals and Maintenance
- Notice Date
- 7/26/2012
- Notice Type
- Sources Sought
- NAICS
- 423830
— Industrial Machinery and Equipment Merchant Wholesalers
- Contracting Office
- Department of Energy, Bechtel National, Inc. (DOE Contractor), Bechtel National Inc., 2435 Stevens Center Place, Richland, Washington, 99352
- ZIP Code
- 99352
- Solicitation Number
- 24590-NP-FSR-AE00-004630
- Point of Contact
- Winifred Renz, Phone: 5093712338
- E-Mail Address
-
werenz@bechtel.com
(werenz@bechtel.com)
- Small Business Set-Aside
- N/A
- Description
- Parts washer including Cleaning & Disposal of Chemical Subcontract Requisition Number: 24590-NP-FSR-AE00-04630 Submit Interest By: July 31, 2012 Estimated Budget: <$20,000 to $30,000> Schedule: •· Issue Request for Proposal: August 15, 2012 •· Award and Notice to Proceed: October 5, 2012 •· Start Work: October 15, 2012 •· All Work Complete: October 14, 2017 Safety Classification: Non-ITS Additional Characteristic: None Quality Level: CM Type of Subcontract: Firm Fixed Price PROJECT DESCRIPTION AND LOCATION The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is a complex of radioactive waste treatment processing facilities designed and constructed by Bechtel National, Inc. for the Department of Energy (DOE). The facility will process the Hanford Site tank waste and convert the waste into a stable glass form. The Project site is located in the 200 East Area of the Hanford Reservation near Richland, Washington, along the Columbia River. The site elevation varies from 662 to 684 feet above mean sea level. Ambient temperature range is -23 degrees F minimum to 113 degrees F maximum, with relative humidity of 5% minimum to 100% maximum. The project design life is 40 years. SCOPE OF WORK SUBCONTRACTOR shall provide parts cleaning equipment and services at the River Protection Project, Waste Treatment Plant (WTP) located at the 200 East area of the Hanford Reservation. Work associated with this subcontract shall include but is not limited to: SUBCONTRACTOR shall provide to CONTRACTOR use of parts cleaners. Parts cleaner shall, at minimum, meet the Industry standard specifications for Parts Vat Cleaner as follows: •a) Operation Type: Manual •b) Type: Vat-Style •c) Depth: nominal 24 inches •d) Height at Tank: not more than 36 inches •e) Height with Lid Open: nominal 60 to 72 inches •f) Width: nominal 45 inches •g) Freeboard Depth: not less than 9 inches •h) Electric Power: 115 VAC •i) Standard Fill: nominal 34 gallons •j) Operating Temperature: Ambient •k) Material: Steel •l) Maximum Work Load: not less than 250 lbs P arts cleaner shall, at minimum, meet the Industry standard specifications for Parts Vat Cleaner as follows: •a) Operation Type: Manual •b) Type: Sink-on-a-drum •c) Depth: nominal 20.5 inches •d) Height at Tank: not more than 36 inches •e) Height with Lid Open: nominal 54 inches •f) Width: nominal 31 inches •g) Freeboard Depth: not less than 9 inches •h) Electric Power: 115 VAC •i) Standard Fill: nominal 9 gallons •j) Operating Temperature: Ambient •k) Material: Steel P arts cleaner shall, at minimum, meet the Industry standard specifications for a Parts Vat Cleaner as follows: •a) Operation Type: Automatic/M anual •b) Type: Vat-Style •c) Depth: nominal 37 i nches •d) Height at Tank: not more than 36 inches •e) Height with Lid Open: nominal 69 inc hes •f) Width: nominal 52 inches •g) Freeboard Depth: not less than 14 inches •h) Electric Power: 115 VA C •i) Standard Fill: max 80 gallons •j) Operating Temperature: Ambien t •k) Material: Steel Parts cleaner shall be rated for use at industrial and automotive facilities that require cleaning less than 50 small to medium parts per hour with light to moderate soil. The degree of cleanliness shall be for general maintenance. SUBCONTRACTOR shall provide CONTRACTOR with the following services: Labor and material necessary to service and maintain parts cleaners in accordance with manufacturer's specifications. Provide to CONTRACTOR use of solvent for the parts cleaners. The solvent shall not have a flash point below 148º F. Replenish each parts cleaner with fresh solvent as requested by CONTRACTOR. (Note: Frequency of requests will increase and decrease with construction level of effort. (Norm is anticipated to be once every four weeks.) Clean and maintain each parts cleaner in accordance with manufacturer's specifications. (Note: Required cleaning and maintenance shall be conducted during the pre-scheduled visits to replenish solvent.) Collect, package, transport, recycle, and dispose of used solvent and residual materials in compliance with local, state, and federal regulations. Provide for CONTRACTOR review and approval, the Material Safety Data Sheet (MSDS) for the solvent prior to use. Solvent shall be a non-hazardous, recyclable product. QUALITY ASSURANCE (QA) REQUIREMENTS Programmatic Quality Assurance requirements for subcontracts performed in the WTP Jobsite will be "NP" (non permanent or temporary work, generally no QA Program required), "CM" (commercial quality based the requirements in DOE Order 414.1C), or "QL" (nuclear level quality based on the requirements in ASME NQA-1 2000). Bechtel may require, as an element of bidder pre-qualification, submission of a representative sample QA Program or Table of Contents copy. For QL subcontracts, the successful bidder's QA Program must be approved prior to award of the subcontract. CODES (SAMPLE) •· International Code Council (ICC), Uniform Building Code (UBC) •· International Code Council (ICC), International Building Code (IBC) •· National Fire Protection Association (NFPA) 101, Life Safety Code •· NFPA 30, Flammable and Combustible Liquids Code •· NFPA 70, National Electrical Code •· Uniform Mechanical Code (UMC) •· Uniform Plumbing Code (UPC) •· US Department of Energy (DOE) Orders STANDARDS (SAMPLE) •· American National Standards Institute (ANSI) •· American Society for Testing and Materials (ASTM) •· Builders Hardware Manufacturers Association (BHMA) •· Door and Hardware Institute (DHI) •· Gypsum Association (GA) •· Factory Mutual (FM) •· Hollow Metal Manufacturers Association (HMMA) •· International Firestop Council (IFC) •· Painting and Decorating Contractors of America (PDCA) •· Standards for Safety Laboratory Hoods and Cabinets (UL 1805) •· Scientific Equipment and Furniture Association (SEFA) •· Steel Door Institute (SDI) •· Underwriters Laboratories, Inc (UL) •· National Electrical Manufacturers Association (NEMA) Standards •· American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Handbooks, Fundamentals, Application, Systems and Equipment BIDDER REGISTRATION AND PRE-QUALIFICATION Preliminary Pre-Qualification Requirements The BNI Acquisition Services Subcontracts group is responsible for collection, evaluation, and internal publication of potential bidders' information for the purpose of pre-qualifying them to bid on any particular subcontract. As part of this process, BNI requires all potential offerors to register at the Supplier and Contractor Portal at: https://supplier.bechtel.com Prior to being considered for bidding on a Request For Proposal (RFP) for this WTP web posting opportunity, potential bidders must complete and submit the required forms located at http://www.hanfordvitplant.com/supplier_resources/qualification_process/ All information provided shall be strictly confidential. Registration All bidders must register with Bechtel National, Inc. for Work on the WTP Project. If your company has registered previously, then only supplemental information should be sent to the Bechtel National, Inc. representative noted below. Information to be provided by potential bidders must include: •· Dun and Bradstreet #: •· Company Name: •· Company Address: •· Contact Phone #: •· Contact Fax #: •· Contact Person: •· E-mail Address: •· Safety data and information •· Applicable work experience and Projects WTP BACKGROUND Information about the WTP Project can be found on http://www.hanfordvitplant.com CONTACT Bechtel National, Inc. 2435 Stevens Center Place Richland, WA 99354 Attn: Ousman Kinteh Tel. No. 509-371-4455 Email address: okkinteh@bechtel.com Mailstop: MS14-3A
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/BNI/BNI/24590-NP-FSR-AE00-004630/listing.html)
- Place of Performance
- Address: Waste Treatment Plant (WTP) located at the 200 East area of the Hanford Reservation. North of Richland, WA, Richland, Washington, 99354, United States
- Zip Code: 99354
- Zip Code: 99354
- Record
- SN02816820-W 20120728/120727000454-10baac2413b2b8f4d6757a1e5752bc35 (fbodaily.com)