Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 12, 2012 FBO #3883
MODIFICATION

66 -- OPTICAL CRYOGENIC SYSTEM

Notice Date
7/10/2012
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640
 
ZIP Code
20899-1640
 
Solicitation Number
SB1341-12-RQ-0355
 
Archive Date
7/26/2012
 
Point of Contact
Lynda M Roark, Phone: 3019753725, Patrick K Staines, Phone: (301)975-6335
 
E-Mail Address
Lynda.Roark@nist.gov, patrick.staines@nist.gov
(Lynda.Roark@nist.gov, patrick.staines@nist.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
AMENDMENT 2: THE PURPOSE OF THIS AMENDMENT IS TO ANSWER QUESTIONS AND AMEND SPECIFICATION NUMBER 8. QUESTION 1: IS THE 15 MINUTE COOLDOWN TO 10K A STRICT REQUIREMENT? ANSWER 1: YES IT IS. QUESTION 2: IS THE AUTOMATION A STRICT REQUIREMENT? ANSWER 2: THE FULLY AUTOMATED TEMPERATURE CONTROL OVER THE WHOLE TEMPERATURE RANGE VIA COMPUTER INTERFACE IS A STRICT REUQIREMENT, HOWEVER, AUTOMATION FOR THE PUMP IS NOT. SPECIFICATION 8 IS AMENDED BELOW. QUESTION 3: DOES THE CRYOSTAT NEED A CONSTANT SUPPLY OF LN2 AND LIQUID HELIUM: ANSWER 3: THE CRYOSTAT WILL USE A CONSTANT SUPPLY OF CRYOGEN TO RUN EXPERIMENTS AT A DESIRED TEMPERATURE. IT WUILL USE EITHER LN2 (>77K) ONLY OR L HE (>4 K) FOR MEASUREMENTS. THE CRYOGEN IS SEPARATE AND THE CRYOGEN SUPPLY IS NOT PART OF THIS SOLICITATION. QUESTION 4: ARE THERE TWO SEPARATE HOSES FOR THE TWO CRYOGENS (HELIUM AND LN2)? ANSWER 4: NO QUESTION 5: IS A TRIPLE WALLED HOSE REQUIRED IN WHICH THE LIQUID NITROGEN IS KEEPING THE LIQUID HELIUM SUB-COOLED? ANSWER 5: NO SPECIFICATION 8 IS HEREBY AMENDED AS FOLLOWS: FROM: COOL-DOWN AND PUMP-OUT MUST BE FULLY AUTOMATED AND CONTROLLED VIA COMPUTER INTERFACE. TO: COOL-DOWN MUST BE FULLY AUTOMATED AND CONTROLLED VIA COMPUTER INTERFACE. PUMP-OUT MAY BE MANUALLY CONTROLLED OR FULLY AUTOMATED. ALL OTHER TERMS REMAIN UNCHANGED.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-12-RQ-0355/listing.html)
 
Place of Performance
Address: 100 BUREAU DRIVE, GAITHERSBURG, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN02798798-W 20120712/120711000051-4e6861abbb45f2e3f3bff89d446e2c0a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.