SOURCES SOUGHT
99 -- EPC of a Single PJM Control Platform
- Notice Date
- 7/10/2012
- Notice Type
- Sources Sought
- NAICS
- 332999
— All Other Miscellaneous Fabricated Metal Product Manufacturing
- Contracting Office
- Department of Energy, Bechtel National, Inc. (DOE Contractor), Bechtel National Inc., 2435 Stevens Center Place, Richland, Washington, 99352
- ZIP Code
- 99352
- Solicitation Number
- 24590-QL-SRA-M00Z-00012
- Point of Contact
- Winifred Renz, Phone: 5093712338
- E-Mail Address
-
werenz@bechtel.com
(werenz@bechtel.com)
- Small Business Set-Aside
- N/A
- Description
- EPC OF SINGLE PJM CONTROL PLATFORM Subcontract Requisition Number: 24590-QL-SRA-M00Z-00012 Submit Interest By: July 16, 2012 Estimated Budget: > $5,000,000 Schedule: • Issue Request for Proposal: September 13, 2012 • Award: October 11, 2012 • Notice to Proceed: November 08, 2012 • Start Work: November 09, 2012 • All Work Complete: April 12, 2013 Safety Classification: Non-Safety Additional Characteristic: None Quality Level: CM Type of Subcontract: Firm Fixed Price PROJECT DESCRIPTION AND LOCATION The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is a complex of radioactive waste treatment processing facilities designed and constructed by Bechtel National, Inc. for the Department of Energy (DOE). The facility will process the Hanford Site tank waste and convert the waste into a stable glass form. The Project site is located in the 200 East Area of the Hanford Reservation near Richland, Washington, along the Columbia River. The site elevation varies from 662 to 684 feet above mean sea level. Ambient temperature range is -23 degrees F minimum to 113 degrees F maximum, with relative humidity of 5% minimum to 100% maximum. The project design life is 40 years. SCOPE OF WORK SUBCONTRACTOR performs all work necessary to complete a detailed design, procure, fabricate, install, and perform an acceptance test of the Single PJM Test Platform. This includes providing a facility, utilities and necessary permitting required to allow safe operations of the Single PJM Test Platform. Utilities will include compressed air supply, vacuum systems, electrical power, permits, etc. The Single PJM Test Platform will be used as a NQA-1 test platform intended for design verification of the PJM Control system. It is the only test platform intended to verify the design with high operating temperature fluids. The Single PJM Test Platform will also provide a basis for the selection of the control strategy. The Single PJM Test Platform is a full scale-single train system which uses a full length level/density bubbler, a Jet Pump Pairs, and a full size PJM to assess control performance. Scope of work includes Project Management, detailed design, procurement, fabrication, installation, functional test of the Single PJM Test Platform equipment at CONTRACTORS test facility, and interface with NQA-1 test operations contractor. The scope includes identification of maintenance and inspection requirements, preparation of operation/equipment manuals, and performance of a process hazards analysis. Project management activities include preparing a detailed design and fabrication schedule including milestone dates, submitting monthly progress reports (schedule and cost variance analysis, change control log, 30/60 day look ahead, Estimate At Completion (EAC), and action item log), and performing periodic design reviews (including documentation of issues and resolutions). QUALITY ASSURANCE (QA) REQUIREMENTS Programmatic Quality Assurance requirements for subcontracts performed in the WTP Jobsite will be "NP" (non permanent or temporary work, generally no QA Program required), "CM" (commercial quality based the requirements in DOE Order 414.1C), or "QL" (nuclear level quality based on the requirements in ASME NQA-1 2000). Bechtel may require, as an element of bidder pre-qualification, submission of a representative sample QA Program or Table of Contents copy. For QL subcontracts, the successful bidder's QA Program must be approved prior to award of the subcontract. CODES PIPING ASME B31.1 Power Piping, 2004 Addenda, 2005 ASME Section VIII, Div. 1, Pressure Vessels, Edition 2004 Addenda 2006 ASME Section IX, Welding and Brazing, Edition 2004 Addenda 2006 NBIC, Repairs and Alterations, Edition 2004 Addendum 2006 API TANKS API 650, Storage Tanks, Tenth Edition Addendum 4 December 2005 API 653, Tank Inspection, Repair, Alteration and Reconstruction, Addendum 2, Nov. 2005 STRUCTURAL STEEL AISC, American Institute of Steel Construction, Ninth Edition AWS D1.1 Structural Welding Code, 20th Edition 2006 CONCRETE ACI 318-05, Building Code and Commentary UBC, Uniform Building Code, Edition 1997 ELECTRICAL/INSTRUMENTATION NFPA 70, 2005 National Electric Code BUILDINGS UBC, Uniform Building Code, Edition 1997 ASCE, Design Loads for Building and Other Structures, 7-02 International Building Code (IBC) and International Fire Code (IFC), 2003 Editions, as required by Richland Municipal Code (RMC), Titles 20 & 21 STATE AND OR FEDERAL SAFETY REGULATIONS OSHA/WISHA 29 CFR Parts 1900 to 1926, July 2006 1910 Subpart D - Walking - Working Surfaces 1910 Subpart O - Machinery and Machine Guarding 1910 Subpart S - Electrical WAC 296-24, Part J-1, Working Surfaces, Guarding Floor and Wall Openings WAC 296-86, Machine Safety WAC 296-800-280, Basic Electrical Rules WISHA, Washington Industrial Safety and Health Act, Chapter 296-800 WAC, November 2004 BIDDER REGISTRATION AND PRE-QUALIFICATION Preliminary Pre-Qualification Requirements The BNI Acquisition Services Subcontracts group, is responsible for collection, evaluation, and internal publication of potential bidders' information for the purpose of pre-qualifying them to bid on any particular subcontract. As part of this process, BNI requires all potential offerors to register at the Supplier and Contractor Portal at: https://supplier.bechtel.com Prior to being considered for bidding on a Request For Proposal (RFP) for this WTP web posting opportunity, potential bidders must complete and submit the required forms located at http://www.hanfordvitplant.com/supplier_resources/qualification_process/ All information provided shall be strictly confidential. Registration All bidders must register with Bechtel National, Inc. for Work on the WTP Project. If your company has registered previously, then only supplemental information should be sent to the Bechtel National, Inc. representative noted below. Information to be provided by potential bidders must include: • Dun and Bradstreet #: • Company Name: • Company Address: • Contact Phone #: • Contact Fax #: • Contact Person: • E-mail Address: • Safety data and information • Applicable work experience and Projects WTP BACKGROUND Information about the WTP Project can be found on http://www.hanfordvitplant.com CONTACT Bechtel National, Inc. 2435 Stevens Center Place Richland, WA 99354 Attn: Lisa Carlin Tel. No. 509-371-2078 Email address: lmcarlin@Bechtel.com Mailstop: MS14-3A
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/BNI/BNI/24590-QL-SRA-M00Z-00012/listing.html)
- Place of Performance
- Address: Offerors to propose execution plan., United States
- Record
- SN02798592-W 20120712/120710235811-c14007ad4bf4f00c2816bd3ba2e50884 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)