SOURCES SOUGHT
Z -- Boiler # 2 Replacement
- Notice Date
- 6/29/2012
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services, Bldg 50 Room 422, Jefferson, Arkansas, 72079, United States
- ZIP Code
- 72079
- Solicitation Number
- FDA1105693
- Archive Date
- 7/28/2012
- Point of Contact
- Nicholas E Sartain, Phone: 870-543-7370
- E-Mail Address
-
nick.sartain@fda.hhs.gov
(nick.sartain@fda.hhs.gov)
- Small Business Set-Aside
- N/A
- Description
- THIS IS FOR MARKET RESEARCH PURPOSES ONLY, NOT A REQUEST FOR PROPOSAL OR SOLICITATION. The Food and Drug Administration, Jefferson Laboratories, in Jefferson, Arkansas, is conducting market research in seeking business sources within the Arkansas service area, including total small businesses, service-disabled veteran-owned small businesses, HUBZone small businesses and Women Owned Small businesses. The following information is provided to assist the FDA in conducting Market Research to identify potential contractors for this effort: The government is seeking sources interested in the following project. This project includes replacing of existing water tube boiler #2 with new fire tube boiler with master Boiler control system. The scope of work also includes removal of the existing water tube boiler, Asbestos abatement of the existing water tube boiler, structural steel, roofing repairs and electrical upgrades. Options include; removal of exiting Feed water pumps, removal of existing DA tank and Surge tanks, removal of Feed water pipe in existing trench. Firms believing they can meet the requirements above shall furnish sufficient technical information necessary for the Government to conclusively determine the experience and qualifications of the firm for the above project with no less than the following information: • Business name, DUNS number, business address, business website, business size status (i.e., SB, VOSB, SDVOSB, HUBZone SB, SDB, WOSB, LB), point of contact name, mailing address (if different from business address), phone number and email address; • Capability statements must provide enough information to determine if the company has experience and qualifications to meet the requirement and be not longer than 10 pages. Capability statements must reference similar work as described above within the identified magnitude that has been performed by the contractor in the last three (3) years and a description of the work. Capability statements must provide detailed specific references and experience with removal and installation of fire tube boilers with master boiler controls system, structural steel, roofing and electrical upgrades. Also include experience with removal of exiting feed water pumps, removal of DA tank and Surge tanks. Provide description of work, contract value, customer name and any other information to demonstrate qualifications. Of the identified contracts indicate if the firm was the prime contractor and installer or subcontractor. • Describe how the firms experience and qualifications will be applied to this project to ensure successful completion. Provide if the work was performed with the firm's own employees. • Confirm that the FAR Clause 52.219-14 Limitations on Subcontracting.(NOV 2011) will be met. • If a large business, provide if subcontracting opportunities exist for small business concerns. • Provide suggestion of other appropriate NAICS codes that may be more applicable. Estimated construction magnitude is between $1 million and $5 million. The government is not responsible for locating or securing any information, not identified in the response. The associated North American Industry Classification System (NAICS) Code is- 238220- Plumbing, Heating, and Air-Conditioning Contractors; Small Business Size Standard is $14.0 Million. Interested Contractors must respond with capability statements which are due in person, by postal mail or email to the point of contact listed below on or before July 13, 2012 by 13:00 hours (Central Time in Jefferson, Arkansas) at the Food and Drug Administration, FDA/OO/OFBA/OAGS/DAP, Attn: Nick Sartain, 3900 NCTR Road, HFT-320, Jefferson, AR 72079-9502 or email nick.sartain@fda.hhs.gov. Reference FDA 1105693. Disclaimer and Important Notes. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation. Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s)."
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/FDA/NCTR/FDA1105693/listing.html)
- Place of Performance
- Address: 3900 NCTR Road, Jefferson, Arkansas, 72079, United States
- Zip Code: 72079
- Zip Code: 72079
- Record
- SN02790905-W 20120701/120629235311-972deae7b28955d7a72715f92892c395 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |