SOURCES SOUGHT
99 -- Roof Replacement at the FAA ARTCC Power Service Building, Memphis, TN
- Notice Date
- 6/26/2012
- Notice Type
- Sources Sought
- Contracting Office
- FEDERAL AVIATION ADMINISTRATION, AAQ-510 ASO - Southern
- ZIP Code
- 00000
- Solicitation Number
- DTFAEN-12-R-00096
- Response Due
- 7/20/2012
- Archive Date
- 8/4/2012
- Point of Contact
- Gail Edwards, 404-305-5182
- E-Mail Address
-
gail.edwards@faa.gov
(gail.edwards@faa.gov)
- Small Business Set-Aside
- N/A
- Description
- The FAA is seeking one vendor to execute the following scope of work under requirement number DTFAEN-12-R-00096: Power Service Building Roof N1 - Replace approximately 1,496 square foot of an existing build-up roof with a Thermoplastic Polyolefin membrane roofing system. Remove existing roofing system down to the original deck. Inspect roof deck and repair accordingly if required. Remove the flashing, metal caps and the two existing roof drains. Install new blocking and cants around perimeter and penetrations. Install new rigid insulation in multiple layers with a minimum LTTR of 30. Install a new Thermoplastic Polyolefin membrane roofing system to include new aluminum flashing. Install two (2) new drains. Demo existing copper lightning protection system and install new aluminum lightning protection system. Install a new portable Guard Rail System for fall protection according to the drawings and specifications. This portion of the work is (Optional) - Power Service Building Roof N. The FAA will determine at the end of the bidding process if funding is available to include this portion of work. It is requested that all responders submit a proposal for this portion of work as well. Replace approximately 3441 square foot of an existing build-up roof with a Thermoplastic Polyolefin membrane roofing system. Remove existing roofing system down to the original deck. Inspect roof deck and repair accordingly if required. Remove the flashing, three 4 inch vents and the four existing roof drains. Install new blocking and cants around perimeter and penetrations. Install new rigid insulation in multiple layers with a minimum LTTR of 30. Install a new Thermoplastic Polyolefin membrane roofing system to include aluminum flashing. Install four (4) new drains and three (3) new 4 inch vents. Demo existing copper lightning protection system and install new aluminum class II lightning protection system. Install a new portable Guard Rail System for fall protection according to the drawings and specifications. Performance Period 75 (seventy-five) Calendar Days - Estimated Price Range: $100,000.00 to $150,000.00. A site visit is currently scheduled for July 9, 2012, at 10:00 a.m. EST. Please contact Louri Call at louri.call@faa.gov 48 hours to be included on this site visit. Any questions resulting from this visit, or any aspect of the requirement must be sent in writing to the Contracting Officer at gail.edwards@faa.gov nlt July 20, 2012.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOT/FAA/SR/DTFAEN-12-R-00096/listing.html)
- Record
- SN02786934-W 20120628/120626235716-124888e95546d9d3b24cfdcc926b850f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |