Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 14, 2012 FBO #3855
MODIFICATION

Y -- Repair and Replace Potable Water Treatment System for Davis Dam.

Notice Date
6/12/2012
 
Notice Type
Modification/Amendment
 
Contracting Office
Bureau of Reclamation - LC - Lower Colorado Regional Office P.O. Box 61470 Boulder City NV 89006
 
ZIP Code
89006
 
Solicitation Number
12-011LC
 
Response Due
6/20/2012
 
Archive Date
6/12/2013
 
Point of Contact
Cris Forbes Contract Specialist 7022938149 mforbes@usbr.gov;
 
E-Mail Address
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
 
Small Business Set-Aside
Total Small Business
 
Description
The purpose of this amendment is to revise the Request for Information (RFI), extend the RFI due date to June 20, 2012 and to make drawings and pictures available upon reques. Requests should go to mforbes@usbr.gov. See changes below. This is a Request for Information (RFI) for project planning purposes only. No formal solicitation for this work exists at this time. The Bureau of Reclamation (Reclamation) is seeking information from industry to be used for the development of specifications and the Statement of Work (SOW) for the replacement of the potable water treatment system at Davis Dam, including removal and disposal of the existing water treatment system. The approximate size of the system shall be 250 gpm maximum flow rate and average daily flow rate of approximately 30,000 gpd. The Davis Dam water treatment system is located one level below the transformer deck on the south end deck (downstream side). There is an access hatch on the transformer deck that provides direct access to the water treatment system room. Currently, Davis Dam utilizes a gas chlorination system that is located in a hazardous materials room on top of the transformer deck. The gas chlorine feeds into the water filtration system located on the lower level below the transformer deck. Davis Dam is looking at installing a new water treatment system which should eliminate gas chlorine and intends to stay away from liquid chlorine due to storage issues from the temperature. Roadway to transformer deck: Two lane 12 foot wide lane. Proper security measures will need to be taken for contractor access to Davis Dam facilities. Dimensions Water Treatment Room: 28' X 35' Drawings & Photographs 351-D-735 (Plan View Plant Layout) 351-D- XXXX (Pipe and Tank Layout) 351-D-1623 (Water Supply Lines) 351-D-2141 (Plan View Plant Layout) 1.Water treatment plant room 2.Roof Access 3.Chlorination room entrance 4.Chlorination room Drawings and Photographs will be made available upon request. Please email your request to Cris Forbes at mforbes@usbr.gov. Goal/Requirements of replacement of potable water system: 1.Maintain fire suppression and domestic water systems during installation except for a short allowable timeframe to switch operation to the new system. 2.The system shall minimize both costs of system as well as future O&M costs. Response to RFI should include: 1.Name, address and contact information of party submitting a response to the RFI. 2.Description of vendor capabilities and commercial terms and conditions. 3.Comments, suggestions, questions related to the fabrication, materials, drawings, and timeline for installation. 4.Expected long term life of system. under 5.Rough estimates or order-of-magnitude for the fabrication, installation, and annualized long term O&M of a water treatment plant for budgetary purposes only. 6.Rough timeline or order-of-magnitude for installation of water treatment plant. This RFI is issued for information only. Respondents are advised that Reclamation is under no obligation to acknowledge receipt of the information received, or provide feedback to respondents with respect to any information submitted under this RFI. Responses are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. Responses to this RFI are to be submitted no later than 12 pm pacific standard time, Thursday, June 14, 2012. All responses to this RFI shall be submitted to Cris Forbes /LC-10214, Contract Specialist, P. O. Box 61470, Boulder City, NV 89006-1470 or via email address: mforbes@usbr.gov. All questions related to this RFI and requests for drawings shall be submitted in writing to the email addresses above and shall include an email address of the requestor. When it is determined that a formal solicitation will be issued, a pre-solicitation notice will be posted on Federal Business Opportunities web site at http://www.fedbizopps.gov/.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/09108bcbcae89ac6b4c26f13fe6163c6)
 
Place of Performance
Address: Davis Dam, AZ-NV
Zip Code: 864298902
 
Record
SN02773168-W 20120614/120612235136-09108bcbcae89ac6b4c26f13fe6163c6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.