Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 31, 2012 FBO #3841
MODIFICATION

66 -- Pressure Controller/Calibrator

Notice Date
5/29/2012
 
Notice Type
Modification/Amendment
 
NAICS
334513 — Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640
 
ZIP Code
20899-1640
 
Solicitation Number
SB1341-12-RQ-0291
 
Archive Date
6/19/2012
 
Point of Contact
Joni L Laster, Phone: 301-975-8397, Patrick K Staines, Phone: (301)975-6335
 
E-Mail Address
joni.laster@nist.gov, patrick.staines@nist.gov
(joni.laster@nist.gov, patrick.staines@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
The request for quotation is hereby amended to address vendor questions and answers, incorporate a change in the technical specifications, amend the evaluation criteria and extend the due date for quotes as follows: 1. Vendor questions and answers: Question: After reviewing Amendment I and the new specification 1 for Line Item 0001 which states "Pressure Range: Must cover the range 0 to 200 kPa abosolute pressure, preference shall be given to a Vacuum of 1.5 Atmospheres" - This specification is confusing. If the preference is 1.5 atm, how can the specification state that the solution must cover a 0 to 2 atm (200 kPa) range? In the Vendor Question and Answer section, the answer to the question is "1.5 atm is the preference, 2 atm would be considered if all other minimum specifications are met". This statement is different than "Must cover the range of 0 to 200 kPa". Please clarify. Answer: The instrument must cover the range of 0 to 150 kPa absolute pressure. The reference to 200 kPa has been deleted in its entirety (see revised specification 1 below). Regarding the new item 5 which states "Total uncertainty: at least 0.01% at 100,000 Pa (preference shall be given to a smaller uncertainty)" - Is the product preference for a product whose absolute uncertainty for pressure measurements below 100,000 Pa improves to better than +/- 10 Pa (0.01% of 100,000 Pa)? Answer: Preference is for a product whose uncertainty at 100 kPa is less than 0.01% (10 pa). 2. Line Item 0001 specification 1 is hereby amended as follows to remove all reference to 200 kPa as stated below: FROM: Line Item 0001: Quantity Two (2) each, Controller/Calibrator that shall meet or exceed the following minimum specifications: 1. Pressure Range: Must cover the range 0 to 200 kPa absolute pressure (Vacuum to 1.5 Atmospheres); TO: Line Item 0001: Quantity Two (2) each, Controller/Calibrator that shall meet or exceed the following minimum specifications: 1. Pressure Range: Must cover the range 0 to 150 kPa absolute pressure (REVISED) 3. Evaluation Criteria is hereby amended as follows: FROM: Evaluation Criteria: The Government will award a purchase order resulting from this solicitation to the responsible quoter whose quotation, conforming to the solicitation, results in the best value to the Government, price and other factors considered. The following will be used to evaluate quotations: Technical Capability and Price. Technical Capability shall be approximately equal in importance to price. In determining best value, preference shall be given to equipment that is capable of exceeding the minimum specifications of those stated above in specifications 1 (Pressure Range) & 5 (total uncertainty). TO: Evaluation Criteria: The Government will award a purchase order resulting from this solicitation to the responsible quoter whose quotation, conforming to the solicitation, results in the best value to the Government, price and other factors considered. The following will be used to evaluate quotations: Technical Capability and Price. Technical Capability shall be approximately equal in importance to price. In determining best value, preference shall be given to equipment that is capable of exceeding the minimum specification of specification 5 (total uncertainty). The due date/time has been extended through June 4, 2012.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-12-RQ-0291/listing.html)
 
Place of Performance
Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN02760554-W 20120531/120529235550-36fad9681713226343571ea7f885dc6e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.