Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 23, 2012 FBO #3833
SOURCES SOUGHT

Z -- Roof Coating

Notice Date
5/21/2012
 
Notice Type
Sources Sought
 
NAICS
238160 — Roofing Contractors
 
Contracting Office
Department of the Air Force, Air Combat Command, 355 CONS, 3180 S Craycroft Rd, Davis Monthan AFB, Arizona, 85707-3522
 
ZIP Code
85707-3522
 
Solicitation Number
FA4877-12-Q-0376_Coating
 
Archive Date
6/13/2012
 
Point of Contact
David Velarde, Phone: 5202280041, Ian M. Maxwell, Phone: 5202284830
 
E-Mail Address
david.velarde@dm.af.mil, ian.maxwell@dm.af.mil
(david.velarde@dm.af.mil, ian.maxwell@dm.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
THIS IS MARKET RESEARCH/SOURCES SOUGHT NOTICE SEEKING INFORMATION ONLY. This is a Sources Sought announcement only seeking Small Business responses in order to determine Small Business participation in the acquisition. The 355th Contracting Office, Davis-Monthan AFB (DMAFB) intends to procure Power Wash and Coat Roof services. Requirement is to perform power wash and coat roof service. Sealant should have the following specifications: SPI Super Therm or equivalent, two coats at 16 Mil Wet to all areas. All windows, doors, and areas that need protection will be taped off and protected during coating. Material must meet requirements below; Heat Load Requirement: Application of the material must achieve a surface temperature to remain within 3 degrees of ambient temperature, resulting in thermal emittance of.91 Thermal Efficiency Requirement: Minimum thermal energy efficiency required: Block 95% of Heat Load (absorption and transfer of heat), block 99% Ultra Violet Radiation (3% heat load), block 92% Visual Light/ Short Wave Radiation (40% heat load), and block 99.5% Infra Red/ Long Wave Radiation (57% heat load) Fire Safety Requirement: Class "A" and Class 1 Fire Rating per ASTM E108 Test Method for Fire Test of Roof Covering, E84 Flame Spread/Smoke Developed ASTM Certification Requirements: B117 450 Hour Salt Water Spray, C177 Thermal Conductivity, C236-89/93 Thermal Transmittance-.21K/Conductance, C411 High Temperature Surface, C1371 Emittance of Materials, C1549 Solar Reflectance Near Ambient Temperature, D412 Tensile Properties-.041 thickness= 13,248 psi, D522 Mandrel Bend on metal or rubber-1" (25mm) bend and ¼" (6mm) bend, D1653 Water Vapor Permeability, D3273-82T Fungal Resistance, D3274 Fungal Resistance, D4060 Abrasion Resistance, -Class A and Class 1 Fire Rating, E84-89A Flame Spread Index "0"/Smoke Developed Index "0", E96 Water Vapor Transmission, E108 Flame Spread on Pitched Roof, E903-96 Spectral Reflectance and 4 year retest reflectivity 80%, E1269 Heat Capacity by Differential Scanning Calorimeter, E1461(92) Thermal Diffusivity/Conductivity by Flash Method-Blocked 91% of Heat BTU Conduction, G53 1000 Hours UV exposure, D7088 Superseded Federal Specification TT-P-1411A Hydrostatic Pressure Resistance, D6904 TT-C-555B Water Barrier Certification, E90 & E413 Airborne Sound Transmission Loss Building Code Certification Requirements: Building Officials Code Administration (BOCA), International Conference of Building Materials (ICBO), Southern Building Code Congress International (SBCCI) Flammability and Toxic Off Gas Requirement: National Aeronautics and Space Administration (NASA) NHB 8060.1B/C Test 1 Flammability test, and NASA 8060.1C Test 7 Toxic Off Gassing USDA Requirement: Environmentally safe and eco-effective by MBDC LLC (Gold Certificate) and approved by the USDA for use in and around food preparation areas Acoustic Reduction: Block minimum of 60% of all sound wave transmission Haz-Mat Requirement: No hazardous material issues concerning its storage, use, or waste disposal The designated NAICS Code is 238160, Roofing Contractors, size standard is $14.0 Million. Your response shall include your company's size, CAGE/DUNS codes and the primary point of contact. Documentation of technical expertise and capability must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. It is imperative that business concerns responding to this sources sought articulate their capabilities clearly and adequately The information should be sent to 355 CONS preferably via e-mail to david.velarde@dm.af.mil by 12:00 PST Tuesday 29 May 2012. If mailed, send to ATTN: David Velarde, SSgt, USAF, Contract Administrator, 3180 S. Craycroft Rd. Davis-Monthan Air Force Base, Tucson AZ, 85707-3522. Any questions can be directed to SSgt David Velarde, david.velarde@dm.af.mil or (520)228-0041. IF A SOLICITATION IS ISSUED IT WILL BE ANNOUNCED AT A LATER DATE, and all interested parties must respond to that solicitation announcement separately from the responses to this announcement. No reimbursement will be made for any costs associated with providing information in response to this announcement.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/ACC/355CONS/FA4877-12-Q-0376_Coating/listing.html)
 
Place of Performance
Address: 4860 S. Superior Ave, Tucson, Arizona, 85707, United States
Zip Code: 85707
 
Record
SN02753159-W 20120523/120521234803-ffaa771ad38cfed9bfc54a8a38204194 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.