SPECIAL NOTICE
41 -- CHILLER MODULE REPLACEMENT
- Notice Date
- 5/2/2012
- Notice Type
- Special Notice
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- FWS, DIVISION OF CONTRACTING AND GEEASTSIDE FEDERAL COMPLEX911 NE 11TH AVENUEPORTLANDOR97232-4181US
- ZIP Code
- 00000
- Solicitation Number
- F12PS00404
- Point of Contact
- Franklin Lee
- E-Mail Address
-
tamra_swerdlik@fws.gov
(tamra_swerdlik@fws.gov)
- Small Business Set-Aside
- N/A
- Description
- COMBINED SYNOPSIS/SOLICITATIONPROVIDE REPLACEMENT OF ONE MODULE OF A FOUR MODULE MULTISTACK CHILLER SYSTEM IN THE OZONE PLANT AT THE COLEMAN NATIONAL FISH HATCHERY, ANDERSON, CAU.S. Fish and Wildlife Service, Pacific Region, Portland, OR has a requirement for a commercial item or service. This combined synopsis/solicitation is prepared in accordance with the format in FAR Subpart 12.6 (as supplemented with additional information included in this notice). This posting will be referred to under Request for Quotation (RFQ) Number F12PS00404. This announcement constitutes the only solicitation. A written solicitation will not be issued. This RFQ falls under procedures in FAR Parts 12 and 13. This document incorporates provisions and clauses updated by way of the Federal Acquisition Circular (FAC) #2005-56, effective March 2, 2012. The North American Industrial Classification System (NAICS) number is 238220, Plumbing, Heating, and Air Conditioning Contractors. This announcement constitutes the Government's only official notice of this procurement. The Government does not intend to pay for any information provided under this synopsis.SPECIFICATIONS: Replace one module of a four module chiller. The module to be replaced is compressors three and four, their evaporators and condensers. This will require the removal and replacement of bus bars wiring, supply and return mains for chilled water, and controls. The module is not located on the end so this will require care to prevent damage to the modules on both sides. This may require extra disconnections of wires or mains. The defective parts, recovery of refrigerant, and disposal by EPA standards is the contractors responsibility. All control wiring is plug and play. Incoming voltage is on a bus system from one compartment to the next, a tight fit. Contractor shall provide his own equipment and tools to perform the task, none will be provided. Contractor will charge and run unit to include adjusting the superheat of the new compartment. This chiller is R-22 which contractor will supply. The chiller module will be Multistack from Multistack Inc. Address is 1065 Maple Ave. PO box 510 Sparta Wis. 54656. Chiller ID: MS-50B-HV. Over all height is 60 width 50 and length 48. Was installed 3/16/93 by McLaughlin plumbing and heating. Main power is 460. The original Multistack order number was 970-3001. Delivery/Work location is the Coleman National Fish Hatchery, 24411 Coleman Fish Hatchery Road, Anderson, CA 96007. Telephone No. 530-365-8622Submit quote on company letterhead with all pertinent point of contact information including CCR Cage Code, DUNS No., Tax Id No., and business size/type, telephone number and email. In addition, your quote should provide unit price, total price, delivery date, and terms. No formal format is required as this is a combined synopsis/request for quote solicitation. If your company has a GSA contract, please provide the GSA Contract No. as well. Offers must be received NLT date and time shown in this notice. Quotes may be e-mailed or faxed to: Tamra_Swerdlik@fws.gov or fax: (503) 231-6259.Offerors must comply with all instructions contained Internet Payment Platform (IPP) DOI Electronic Invoicing, and in FAR 52.212-1, Instructions to Offerors - Commercial Items. The provisions at 52.212-2, Evaluation - Commercial Items, applies to this acquisition. Evaluation factors are price and delivery. The clause 52.212-4, Contract Terms and Conditions -Commercial Items, applies to this acquisition. Also included in this acquisition are the following clauses: 52.204-1, 52.204-7, 52.212-3, 52.215-5, 52.225-20, 52.232-1, 52.233-1, 52.243-1, 52.252-5, and 52.252-6. The clause at 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items applies to this acquisition, no addenda applies. Additional FAR clauses cited in this clause applicable to this acquisition are: 52.222-3, 52.222-21, 52.222-26, 52.223-18, 52.225-1, 52.225-13, 52.232-33, 52.233-3, 52.233-4. The full text of any solicitation provision or clauses referenced herein may be accessed electronically at https://www.acquisition.gov/far/In order to have a quote considered, all quoters mut be registered on the Central Contractor Registration (CCR) website (www.ccr.gov) as an active vendor, and must have completed FAR 52.212-3 in On-line Representations and Certifications Application (ORCA) website (https://orca.bpn.gov) by the closing date of this solicitation. Quotes received from firms not registered in CCR and ORCA by the closing date of the solicitation will not be considered. All questions regarding the subject synopsis/solicitation shall be directed to the attention of Tamra_Swerdlik@fws.gov or telephone: (503) 872-2819.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOI/FWS/CGSWO/F12PS00404/listing.html)
- Record
- SN02737453-W 20120504/120502235916-9d2082864165f7a11aef5a811e890884 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |