Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 03, 2012 FBO #3813
DOCUMENT

J -- REPAIR BOILER AND CHILLER HVAC REPAIRS, NOSC PEORIA IL - Attachment

Notice Date
5/1/2012
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
N40083 NAVFAC MIDWEST PWD CENTRAL FEAD 520 Dewy Ave. Bldg 5 Great Lakes, IL
 
Solicitation Number
N4008312R1032
 
Response Due
5/11/2012
 
Archive Date
5/26/2012
 
Point of Contact
Tom Stevens 847 688 3368 x106
 
Small Business Set-Aside
Woman Owned Small Business
 
Description
The work involves demolition, renovation and new construction for improvement of the HVAC systems in Building 19 of the Navy Operational Support Center, Peoria, Illinois. The work includes demolishing two air handling units and replacing them with new units, demolishing the hot water boiler and providing two new high efficiency condensing boilers, demolishing and replacing the hot water piping in the boiler room, hot water circulating pumps, hot water expansion tank, hot water air separator and pot feeder, demolishing the indoor chiller and its associated outdoor condensing unit and providing a new outdoor air cooled chiller, demolishing and replacing the chilled water piping in the boiler room, chilled water circulating pump, chilled water expansion tank, chilled water air separator, and pot feeder, demolishing the existing HVAC pneumatic control system and the Network controllers and providing a new DDC control system, demolishing the existing exhaust fans serving the basement toilet and locker rooms and providing a new energy recovery ventilation unit for the basement toilet and locker rooms, demolishing and replacing the existing exhaust fan serving the first and second floor toilet and locker rooms, demolishing the exhaust fans in drill hall storage rooms 125 and 127 and providing an exhaust relief fan in the drill hall ductwork that will be interconnected with the drill hall air handler ™s outside air damper, demolishing the unit heaters and exhaust fans in the fitness room and providing a heating and cooling system for the fitness room, and providing testing and balancing of the HVAC and exhaust systems including adding volume dampers in existing ductwork as required.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N40083B/N4008312R1032/listing.html)
 
Document(s)
Attachment
 
File Name: N4008312R1032_PEORIA_ss_questionnaire.pdf (https://www.neco.navy.mil/synopsis_file/N4008312R1032_PEORIA_ss_questionnaire.pdf)
Link: https://www.neco.navy.mil/synopsis_file/N4008312R1032_PEORIA_ss_questionnaire.pdf

 
File Name: N4008312R1032_sources_sought_template_peoria.docx (https://www.neco.navy.mil/synopsis_file/N4008312R1032_sources_sought_template_peoria.docx)
Link: https://www.neco.navy.mil/synopsis_file/N4008312R1032_sources_sought_template_peoria.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02735786-W 20120503/120501235754-012921a4aee366d95e015ad6d07c2cec (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.