SOURCES SOUGHT
63 -- THIS IS A NOTICE OF INTENT ONLY FOR FIRE ALARM SYSTEM EQUIPMENT
- Notice Date
- 4/11/2012
- Notice Type
- Sources Sought
- NAICS
- 561621
— Security Systems Services (except Locksmiths)
- Contracting Office
- USACE District, Los Angeles, P.O. Box 532711, Los Angeles, CA 90053-2325
- ZIP Code
- 90053-2325
- Solicitation Number
- W912PL-12-S-0016
- Response Due
- 4/20/2012
- Archive Date
- 6/19/2012
- Point of Contact
- Diane Watkins, (213)452-3251
- E-Mail Address
-
USACE District, Los Angeles
(diane.l.watkins@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A NOTICE OF INTENT ONLY AND NOT A REQUEST FOR COMPETITIVE PROPOSALS. The U.S. Army Corps of Engineers, Los Angeles District, intends to specify the sole source system/items cited below for Monaco Fire Alarm Systems to support an anticipated future procurement for the following project at Davis-Monthan Air Force Base, Pima County, Arizona. EC-130H SIMULATOR/TRAINING OPERATIONS FACILITY: This facility will house flight deck and mission crew simulators that provide realistic training to support mission readiness. The facility also provides space for academics, squadron operations, administration, classrooms, training maintenance and storage. This facility shall comply with DoD force protection requirements per unified facilities criteria and meet and be certified LEED Silver under the USGBC LEED-NC Rating System. The project will include intrusion detection systems (IDS), connection to the base-wide energy monitoring and control system (EMCS) and building information systems. Supporting facilities include all utilities services, site lighting, fire protection and alarm systems, and lightning protection. Sustainable Design and Development (SDD) and Energy Policy Act of 2005 (EPAct05) features will be provided. This project will comply with all applicable standards and codes, including the DOD Anti-Terrorism/Force Protection requirements per UFC 4-010-01. Davis-Monthan Air Force Base utilizes the sole source systems/items cited below by a single manufacturer for consistency, compatibility and sustainability. The sole source system(s)/item(s), Monaco Fire Alarm systems is part of existing base-wide systems of the same manufacturer. Systems, equipment and devices will be required to be fully compatible and operable with the existing base-wide system. Systems, equipment and devices to be installed, configured, operated, and maintained to include any software programming features shall not impair reliability or operational functions of those existing base-wide systems already in use. The use of Other than Full and Open Competition for these items is authorized by FAR 6.302-1 where a substantial duplication in cost to the Government is not expected to be recovered through competition. No solicitation is available, however, all submittals received within 10 days of this publication will be considered by the Government. A determination by the Government to use sole source specifications is solely within the discretion of the Government. Monaco Fire Alarm systems: GENERAL PRODUCT REQUIREMENT. All fire alarm and mass notification equipment shall be listed for use under the applicable reference standards and shall be Simplex Grinnell. Interfacing of Listed UL 864 or similar approved industry listing with Mass Notification Panels listed to UL 2017 shall be done in a laboratory listed configuration, if the software programming features cannot provide a listed interface control. SYSTEM OPERATION. The Addressable Interior Fire Alarm and Mass Notification System shall be a complete, supervised, noncoded, analog/addressable fire alarm and mass notification system conforming to NFPA 72, UL 864 Ninth Edition, and UL 2017. The system shall be activated into the alarm mode by actuation of any alarm initiating device. The system shall remain in the alarm mode until the initiating device is reset and the fire alarm control panel is reset and restored to normal. The system may be placed in the alert mode by local microphones or remotely from authorized locations/users. Please provide a written statement of compliance and a technical description of your company's product{s) to include descriptive literature and technical specifications necessary to support that compliance. Also include a list of projects in which the proposed manufacturer system/item has met similar integration and compatibility with existing base-wide systems. The list shall include the exact location of project(s) and a point of contact for the base or owners representative contact with phone numbers. Point of contact is Diane Watkins, Contract Specialist. Capability responses and inquiries will only be accepted electronically by email at: diane.l.watkins@usace.army.mil. Capability responses should include product descriptive literature and technical specifications, your point of contact info (name, phone number, email), and pricing info. Please provide. All interested parties must submit their responses to: diane.l.watkins@usace.army.mil. no later than 2:00 PM (PST) on 20 April 2012. Capability responses sent to any other email address will not be accepted. This notice of intent shall not be construed as a Request for Quote or as an obligation on the part of the Government. The Government does not intend to award a contract on the basis of this sources sought or otherwise pay for information requested. Proprietary information is not being solicited; however, if it is submitted, it should be appropriately marked. Respondents will not be notified of the results of this surveyor results of information submitted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA09/W912PL-12-S-0016/listing.html)
- Place of Performance
- Address: USACE District, Los Angeles P.O. Box 532711, Los Angeles CA
- Zip Code: 90053-2325
- Zip Code: 90053-2325
- Record
- SN02719241-W 20120413/120411234911-89b1a6f484c2195324433810805dd343 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |