Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 08, 2012 FBO #3788
SOURCES SOUGHT

58 -- FMS Case EG-B-UXS

Notice Date
4/6/2012
 
Notice Type
Sources Sought
 
Contracting Office
ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
 
ZIP Code
21005-1846
 
Solicitation Number
MARKET-SURVEY-5263-1
 
Response Due
4/20/2012
 
Archive Date
6/19/2012
 
Point of Contact
Tineka C. Davis, 443-861-5438
 
E-Mail Address
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
FOR ALL INFORMATION PLEASE CONTACT: Mitch Jacquay 443-861-4396 mitchell.a.jacquay.civ@mail.mil, Franklin Lee 443-861-4395 franklin.f.lee.ctr@mail.mil **You must respond NO LATER than the Respond Date and Time The ACC-APG -C4ISR intends to acquire the following: Commercial Exportable AVS-6 MX-10160 type GEN III Image Intensifier Tubes NTE 1600 FOM. Salient Characteristics: Figure of Merit: 1400 (minimum) - 1600 (NTE maximum) Resolution: 64 lp/mm (minimum) Diameter: 18 mm Magnification: Unity (1X) Photocathode: GaAs photocathode bonded to a glass input window Sensitivity: 1800 min (at 2856 K, A/lm) 80 min (at 880 nmm, mA/W) Luminance Gain fL/fc: 40,000-70,000 (at 2x10-6 fc) 10,000-20,000 (at 2x10-4 fc) Screen: P-43 Phosphor Spot Size: Zones: 123 0.009-0.012: 000 0.006-0.009: 011 0.003-0.006: 022 Data Sheet: Yes, Tube Data Sheet for each tube with serial number Warranty: 1 year NOTE: All necessary inspections and tests are those inspections and tests typically considered as "A-Test" items identified by the Contractor. All "A-Test" testing, as a minimum, should address all essential form fit, and function specifications/salient characteristics of the items called out in this SOW and Appendix A. Performance specifications outside of typical "A-Test" testing, will be accepted by similarity; however, outside of typical "A-Test" testing data for the "accepted by similarity" product, will be made available for Government review. If more detailed testing is required, such testing and data reporting requirements will be specifically included in the solicitation and potential resulting contract. REQUIRED INFORMATION: 1.If you are a reseller/distributor you MUST disclose the manufacturer of the Tubes. 2.You MUST state delivery ARO of all HARDWARE. 3.If you are a reseller/distributor you MUST disclose the manufacturer of ALL ITEMS listed. 4.If you are a reseller/distributor you MUST provide certification that Night Vision Tubes are NOT Russian made. 5.You MUST reference the FMS case designator on your formal solicitations. 6.Image Intensifier Tube data sheets for each tube with serial number will be requested after contract award 7.There will be a potential call for an incoming inspection by DCMA to check tubes and tube housings 8.A quality system on tubes and tube housings will be requested after contract award. 9.Identify whether you are a small or large business 10.If you are a small business then identify your subcategory, i.e. 8A, SDB, SDVOB, etc. Respond to My Attention by 11 AM Eastern on 20 April 2012 mitchell.a.jacquay.civ@mail.mil, Franklin Lee, EMAIL franklin.f.lee.ctr@mail.mil
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/f21bb0b8427505370640b9fc040c0dac)
 
Place of Performance
Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
Zip Code: 21005-1846
 
Record
SN02716697-W 20120408/120406235449-f21bb0b8427505370640b9fc040c0dac (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.