MODIFICATION
N -- Install Smart Meter - Amendment 1
- Notice Date
- 4/5/2012
- Notice Type
- Modification/Amendment
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- Department of the Army, National Guard Bureau, 103 FW/LGC, BRADLEY ANG BASE, 100 NICHOLSON ROAD, EAST GRANBY, Connecticut, 06026-9309
- ZIP Code
- 06026-9309
- Solicitation Number
- W91ZRS-12-T-0003
- Archive Date
- 5/2/2012
- Point of Contact
- Pablo Ravizzoli, Phone: (860)292-2587, Michael Mastalski,
- E-Mail Address
-
Pablo.Ravizzoli@ang.af.mil, michael.mastalski@us.army.mil
(Pablo.Ravizzoli@ang.af.mil, michael.mastalski@us.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Solicitation with Ammendment 1 The following information is added to the originally posted Statement Of Work. Electric Meters: Shall be ACCUEnergy Acuvim II Series, SquareD PM800, or approved equal. CT only style meters are not acceptable. Meter shall have spare digital input to accept gas and water meter pulses. Current Sensors: Shall be split-core type with removable latching bar for installation flexibility. Current sensors shall be 1% accurate from 1% to 100% of the maximum full scale rating from -15°C to 60°C. Current sensor shall have 8” 18 gauge UL 1015 rated twisted pair wire leads. Gas Meters: Shall be accomplished by coordinating the addition of an additional pulse output module to the existing gas company’s meter, or by installing a separate meter downstream. The goal of the gas meter is to measure total usage in 100 cubic feet (CCF), not real time flow rate (CFM). Any meter providing flow rate and relying on integration to calculate consumption is not acceptable. If separate gas meter is provided something similar to the Itron Dattus III with Modbus TCP or thermal instruments 62-9/9500RG.5316SSPG with pulse output. Gas meter shall have standalone Modbus TCP communication or the pulses can be tied into the digital input on the Electrical meter and transmitted over the wide area network back to the DDC data collection system. Software: Current Automated Logic (ALC) meters software reports are not human readable and the ALC system should be enhanced to include the optional energy reporting package. Software shall enable line charts, column charts, stacked column charts, pie charts, and summary accounting type reports in human readable format. Data must be available to be exported into Microsoft Excel. Installation to meet NEC 2008 requirements Provide 8 hours of training Provide a one year warranty on hardware and software
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA06-1/W91ZRS-12-T-0003/listing.html)
- Place of Performance
- Address: 206 Boston Post Road, Orange, Connecticut, 06477, United States
- Zip Code: 06477
- Zip Code: 06477
- Record
- SN02714852-W 20120407/120405235242-5ce08afd58b1532a7a9f2b9d427db96c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |