Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 04, 2012 FBO #3784
MODIFICATION

Z -- Rehabilitate Spillway Gates, Oahe Dam, SD

Notice Date
4/2/2012
 
Notice Type
Modification/Amendment
 
NAICS
238320 — Painting and Wall Covering Contractors
 
Contracting Office
USACE District, Omaha, 1616 Capital Ave, Omaha, NE 68102-4901
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F12R0025
 
Response Due
5/15/2012
 
Archive Date
7/14/2012
 
Point of Contact
Polina Poluektova, 402-995-2091
 
E-Mail Address
USACE District, Omaha
(polina.a.poluektova@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
On or about 16 April 2012, this office will issue Request for Proposals for design and construction of the Rehabilitate Spillway Gates, Oahe Dam, SD. The solicitation will close on or about 15 May 2012. This solicitation is RESTRICTED TO SMALL BUSINESS PARTICIPATION. A site visit date has been scheduled for 03 May 2012. Contractors are strongly recommended to attend the site visit. Contractors are to meet at 9:00 am outside the Oahe Project Administration Building. There will be a project site walk-thru followed by a 1 to 2 hour technical presentation. Questions concerning the project need to be submitted as per the specifications thru the Bidder Inquiry system "ProjNet" (See Section 00 21 00). Contractors planning to attend the site visit need to make reservations with Kris Cleveland at 605-224-5862 x3001 or email at Kris.Cleveland@usace.army.mil. DO NOT submit requests for plans and specifications to the site visit personnel listed above. See 'Obtaining Solicitation Documents' below. _______________________________________________________________________________ Project Description: (Approx. quantities) The Omaha District, US Army Corps of Engineers is seeking qualified members of the Small Businesses Community that qualify under the North American Industry Classification System (NAICS) Code 238320 - Painting and Wall Covering Contractors. On or around 16 April, the Omaha district will advertise a Best Value Design-Build Request for Proposal project valued from approximately $5.0 to $7.5M. Work shall include the complete rehabilitation of steel tainter gates at Oahe Dam, South Dakota. There are 8 gates that measure 50 feet wide by 23.5 feet high. Work shall include but not be limited to: visual Hydraulic Steel Structure (HSS) inspection of stoplogs and tainter gates, 3-D modeling and analysis utilizing STAAD.Pro software, non-destructive testing, structural repair design, welding (per AWS D1.5M/D1.5), corrosion repair, sandblasting, lead-based paint removal over/near water, wire rope replacement, concrete spall repair, gate seal replacement, concrete construction joint material replacement, cathodic protection removal and installation, design and replacement of hoist controls and switches, localized dredging and certified diving. This work may be subcontracted out to other specialty contractors, as required. The Oahe project office has one set of spillway stoplogs (8 total measuring 3 feet high by 53 feet wide). Typically, due to water elevations, only one, maybe two gates can be isolated at one time. Therefore, work shall be sequenced to be performed while the stoplogs are in place. The contractor shall have the option of fabricating temporary stoplog structures and/or working multiple shifts. The spillway stoplog slots have accumulated a significant amount of sediment. In order to seat the stoplogs, this contract will require localized dredging of the stoplog slots and sill. Dredging shall be accomplished via water jetting, excavation or other approved methods and properly dispose of the collected sediment. A certified diver is required to verify dredging operations have been effective enough to properly seat the stoplogs. Painting work shall include sandblasting spillway gates and associated features to commercial blast, preparing the final surface to SSPC 5 (white metal) and final coating the gates with a vinyl (5-E-Z) coating system with a zinc primer. Work may require the use of scaffolding, snooper crane and harness access. Contractor shall be responsible for dewatering, if required. There will be approximately 1175 square feet of paint required per side per gate with additional quantities for other related features. Taking gates off-site is prohibited. Work may require torch cutting and grinding of new holes for drainage including a structural analysis for altering the gate. Experience in design/analysis of Hydraulic Steel Structures (HSS) is required. Inspection of the structural integrity of the structural members of the gates, including the skin, will be required. Analysis and design of structural repairs and/or replacement of structural members that have been damaged, or severely corroded, may be required. The painting of the gate and associated features is considered the most critical aspect of this project. Contractors will be required to show successful completion of similar projects utilizing 5-E-Z vinyl painting system. Contractors shall have QP-1 and QP-2 Contractor Certifications. Painting qualifications may be amended at a later date. Coating contractor shall be required to hire an independent third party inspector that is NACE-CIP 3, PCS or SSPC-PCI 3 certified. Confined spaces may be a consideration. Please note: Other contractors may be performing work simultaneously in the same general vicinity of the gate work. Contractors will be required to coordinate with other contractors and dam personnel. The estimated construction cost of this project is between $5,000,000 and $7,500,000. _____________________________________________________________________________ The Contractor will be required to commence work within 10 days after notice to proceed and complete the work 720 calendar days after receipt of Notice to Proceed. Provisions will be included for liquidated damages in case of failure to complete the work in the time allowed. Performance and payment bonds will be required. Bonding documents including the power of attorney shall bear an original signature by an officer of the surety. Bidders (Offerors): Please be advised of on-line registration requirement in Central Contractor Registration (CCR) database https://www.bpn.gov/ccr/default.aspx and directed solicitation provisions concerning electronic annual On-line Representations and Certifications (ORCA) at https://orca.bpn.gov. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to ORCA. Obtaining Solicitation Documents: Solicitation documents will be posted to the web via Federal Business Opportunities (www.fbo.gov). Find solicitation announcement in Fed Biz Opps (www.fbo.gov) 1. Use the 'Quick Search' to locate the project (by entering the solicitation number) or use the advanced search features offered in the 'Find Opportunities' (large arrow in the middle of the page) or use the 'Opportunities' tab followed by the 'Advanced Search' tab. 2. By using the 'login' feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted. 3. Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the right side reading 'All Files' or from the 'Packages' tab. 4. If you want other vendors, sub-contractors or contractors to contact you, click on the 'Interested Vendors' tab and then 'Add me to Interested Vendors' link at the bottom of the page. Questions regarding contractual matters should be made to: Polina Poluektova 402- 995-2091. Telephone calls regarding Small Business matters should be made to: 402- 995-2910. Telephone calls on contents of drawings and specifications should be made to the Project Manager at: 402-995-2032 or Specification Section at: 402-995-2184.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA45/W9128F12R0025/listing.html)
 
Place of Performance
Address: USACE Oahe Project Administration Building Pierre SD
Zip Code: 57501
 
Record
SN02711538-W 20120404/120402235006-f8cfc639ed1a51c467950461a8c1dff0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.