SOURCES SOUGHT
61 -- 1KW Soldier Portable Generator
- Notice Date
- 3/29/2012
- Notice Type
- Sources Sought
- NAICS
- 335312
— Motor and Generator Manufacturing
- Contracting Office
- ACC-APG - Washington, ATTN: CCCE-CW, 10205 Burbeck Road, Fort Belvoir, VA 22060-5863
- ZIP Code
- 22060-5863
- Solicitation Number
- W909MY13RE000D
- Response Due
- 4/30/2012
- Archive Date
- 6/29/2012
- Point of Contact
- Charlene Buduo, (703) 704-0860
- E-Mail Address
-
ACC-APG - Washington
(charlene.buduo@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- The US Army Contracting Command-Aberdeen Proving Ground (ACC-APG) Belvoir Division is seeking sources on behalf of the Project Manger Mobile Electric Power (PM MEP) is seeking sources for building and delivering a 1kW Soldier Portable Generator. The Soldier Portable Generator is intended to provide power for battery charging and various types of Army communications and electronics devices. The Soldier Portable Generator will be carried by individual soldiers, so minimizing weight and cube is essential. The generator is intended to provide Platoon power for charging batteries when away from vehicles in SBCT and HBCT, and as a power source for IBCTs in austere environments. Total fielded quantity is expected to exceed 1,800 units. The Government seeks to procure the Soldier Portable Generator competitively and begin fielding systems at the beginning of FY14 (Oct 13). The intent of this market research is to identify potential sources for building and delivering Soldier Portable Generators to support the stated timeline with limited development time required. Responses should include a description of the offeror's capability to develop (if necessary) and produce the Soldier Portable Generator in the timeframe discussed. The Government will accept responses from sources with a demonstrated ability to build an integrated system that meets the following characteristics and performance capabilities: 1) provide a peak of 1kW of power at 24 to 28 Volts DC; 2) ability to burn diesel, ULSD, JP-5 or JP-8 fuel under all operational environments; 3) provide 900 Watts of power at 40 F to +100 F; 4) possess a weight of 45 pounds or less with sufficient JP-8 fuel to run two (2) hours at full electrical load and occupy no more than 3000 cubic inches of space; 5) generator shall include a single point ground lug sized to accommodate two 2 AWG stranded cables. Sources possessing the capability to produce a Soldier Portable Generator that satisfies the requirements listed are invited to submit a White Paper not to exceed 10 pages in length providing a description of their system. The White Paper must include at a minimum: 1) a description of their system and validating information supporting the claims that the proposed system meets the system requirements, 2) technical specifications of their system, 3) estimated cost for a system that meets the system requirements, 4) estimated schedule for delivery of the system. Papers shall also include point (s) of contact (email and phone numbers) for further Government inquiry should more information be desired, name and address of firm, Central Contractor Registration CAGE Code and current level of firm's facility clearance (Secret, Top Secret or No Clearance). Respondents must also include information regarding 1) customary practices (including warranties, discounts, etc.), and under which commercial sales of the products are made, and 2) requirements of any laws and regulations unique to the item being acquired. Papers shall also include: 1. Point (s) of contact (email and phone numbers) for further Government inquiry should more information be desired, name and address of firm, Central Contractor Registration CAGE Code and current level of firm's facility clearance (Secret, Top Secret or No Clearance). 2. Statement as to whether or not your company is considered a small or large business. Please also indicate any socioeconomic classification (8(a), Woman-Owned, Veteran-Owned and Operated, Service-Disabled Veteran-Owned, Operated business, or HUB-Zone) that applies. The small business size standard is 1000 employees for the North American Industry Classification System (NAICS) Code 335312. Additionally, responders should include direct answers to the following questions: a. Are you planning to be the Prime or a Subcontractor? If a Prime (continue to question b) b. If you are a small business and plan to be a Prime please inform how you will meet the limitations on subcontracting Clause 52.219-14? c. If your company is awarded the contract, will you be able to perform at least 50% (percent) of the work required in house? d. The Government understands that teaming is an intricate part of contracting. Please briefly describe how you would approach selecting team members for this requirement if you are not performing this action 100% in house? e. If you are a small business, can your company sustain if not paid for 90 calendar days? f. Can you acquire enough space to perform this task prior to contract award or within 15 calendar days after contract award? g. Has your Company performed this type of effort or similar type effort (to include size and complexity) before, if so provide Contract Number, Point of Contact (POC), e-mail address, phone number, and a brief description of your direct support of the effort? This is NOT a request for proposal and does not constitute any obligation by the Government to award a contract based on the findings from this survey. The Government will not reimburse interested sources or respondents to notice, or any follow-on notice, for any costs incurred in association with this announcement or for subsequent exchanges of information. Proprietary information submitted in response to this Sources Sought shall be marked accordingly and will be protected when clearly identified as proprietary. Response to this Sources Sought should be received no later than 30 calendar days from the date of this notice and should be submitted via email to charlene.buduo@us.army.mil. All requests for further information must be in writing and via email; telephonic requests for additional information will not be honored. You may forward request for additional information and/or responses to Charlene Buduo, Contract Specialist, at charlene.buduo@us.army.mil. Acknowledgement of receipt will be issued. The subject of the email message shall be: Soldier Portable Generator RFI - Your Company's Name.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/8dc4165a4b86402774adc2c951889197)
- Place of Performance
- Address: ACC-APG - Washington ATTN: CCCE-CW, 10205 Burbeck Road Fort Belvoir VA
- Zip Code: 22060-5863
- Zip Code: 22060-5863
- Record
- SN02709048-W 20120331/120329235424-8dc4165a4b86402774adc2c951889197 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |