DOCUMENT
C -- 1JZ BASE POWER DISTRIBUTION UPGRADES AT JOINT EXPEDITIONARY BASE LITTLE CREEK, NORFOLK, VA - Attachment
- Notice Date
- 3/26/2012
- Notice Type
- Attachment
- NAICS
- 237130
— Power and Communication Line and Related Structures Construction
- Contracting Office
- N40085 NAVFAC MID-ATLANTIC Naval Facilities Engineering Command, Mid-Atlantic Code AQ, 9742 Maryland Avenue Norfolk, VA
- Solicitation Number
- N4008512R1732
- Response Due
- 4/24/2012
- Archive Date
- 10/24/2012
- Point of Contact
- Gary Milton, 757-341-1999, gary.milton@navy.mil
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME. Naval Facilities Engineering Command Mid-Atlantic (NAVFAC MIDLANT) is seeking Service-Disabled Veteran-Owned Small Businesses, certified HUB Zone Small Business, and certified 8(a) Small Disadvantaged Businesses with current relevant qualifications, experience, personnel and capability to perform the proposed contracts. NAVFAC MIDLANT anticipates awarding a Design Bid/Build Contract for Base Power Distribution Upgrades at Joint Expeditionary Base Little Creek, Norfolk, VA. General Work Requirements: Project will result in the establishment of an electrical system that meets current and future capacity requirements while increasing reliability of the base distribution system; provides a new main substation on the east of the base for 34.5/13.2 KV electrical distribution; provides a new utility main substation on the west side of the base for 34.5/13.2 KV electrical distribution. The two 34.5 KV substations will provide power to the five existing circuits on the installation. Project also installs new 34.5 KV Main Switchgear to distribute power to the base; installs two new 34.5 KV underwater power distribution cables under the harbor to run from the west side 34.5KN switchgear house to the new east side 34.5/13.2 KV substation. Project will require site improvements for new substations to include grading, some minor access roadway into/around substations, curb, fencing, singes, and storm-water management. Electrical utility work in addition to substation installation and underwater cable installation include new underground and overhead primary distribution and its infrastructure, transformers, and switchgear. The estimated cost range of this construction project is between $10,000,000 and $25,000,000. All Service-Disabled Veteran-Owned Small Businesses, certified HUB Zone Small Business, and certified 8(a) Small Disadvantaged Businesses and other certified small businesses are encouraged to respond. This synopsis is a market research tool being used to determine the availability and adequacy of potential small business sources prior to determining the method of acquisition and ultimate issuance of an award. The Government will not pay for any information solicited. If a full and open competition is ultimately pursued, responses to this synopsis will be used to aid in establishing small business subcontracting goals. All qualified firms are encouraged to respond. It is requested that interested small businesses submit to the contracting officer a brief capabilities statement package (no more than 10 pages in length, single spaced, 12 point font minimum) demonstrating ability to perform the requested services. PAGES IN EXCESS OF THE FIRST 10 PAGES WILL NOT BE CONSIDERED. The documentation shall address, as a minimum, the following: (1) Examples of projects worked within the last five years of similar size, scope and complexity as the work indicated. Knowledge of the state regulations within the AOR. Indicate whether your firm worked as a prime or subcontractor, contract value, brief description of how the referenced contract relates to the work described, and a Government / Agency point of contact. (2) Company profile, to include number of offices and number of employees per office, annual receipts, office location(s), available bonding capacity per contract, DUNS number, and CAGE Code. (3) Please indicate if you are an 8(a), HUB Zone, Service Disabled Veteran Owned, Woman Owned, and Veteran Owned. (4) In order to assist us in determining the geographic boundaries of the contract(s) necessary to cover the services of the proposed requirement within our AOR, please identify the geographic area in which you can operate in an efficient and economical manner. The capabilities package for this sources sought notice is not expected to be a proposal, but rather a short statement regarding the company ™s ability to demonstrate existing, or developed, expertise and experience in relation to this contract. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities package. Submission of a capabilities package is not a prerequisite to any potential future offerings, but participation will assist the Navy in tailoring requirements to be consistent with industry capabilities. The Government anticipates a contract award for these contracts in September 2012. The appropriate NAICS Code is 237130 with a size standard of 500 employees. Responses must be received no later than 2:00 pm Eastern Standard Time on 24 April 2012. Late responses will not be accepted. Responses to this Sources Sought Notice shall be mailed or hand carried to the following address: Commanding Officer Naval Facilities Engineering Command Mid-Atlantic NEIPT 9742 Maryland Ave. (Z-144) Norfolk, VA 23511 Attn: Gary Milton Electronic submission of the statement of capabilities package will not be accepted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62470HR/N4008512R1732/listing.html)
- Document(s)
- Attachment
- File Name: N4008512R1732_Sources_Sought_Notice_for_P499_Power_Distribution_Upgrades.pdf (https://www.neco.navy.mil/synopsis_file/N4008512R1732_Sources_Sought_Notice_for_P499_Power_Distribution_Upgrades.pdf)
- Link: https://www.neco.navy.mil/synopsis_file/N4008512R1732_Sources_Sought_Notice_for_P499_Power_Distribution_Upgrades.pdf
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: N4008512R1732_Sources_Sought_Notice_for_P499_Power_Distribution_Upgrades.pdf (https://www.neco.navy.mil/synopsis_file/N4008512R1732_Sources_Sought_Notice_for_P499_Power_Distribution_Upgrades.pdf)
- Record
- SN02705910-W 20120328/120326235205-b882649018e244b38e0d67e62ba0b557 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)