AWARD
Z -- * For Subcontracting Purposes Only.
- Notice Date
- 3/21/2012
- Notice Type
- Award Notice
- NAICS
- 236210
— Industrial Building Construction
- Contracting Office
- ACC - Rock Island (ACC-RI), ATTN: AMSAS-AC, Rock Island, IL 61299-6500
- ZIP Code
- 61299-6500
- Solicitation Number
- W52P1J12R5007
- Archive Date
- 4/20/2012
- Point of Contact
- Allan Nichols, 309-782-7371
- E-Mail Address
-
ACC - Rock Island (ACC-RI)
(allan.s.nichols.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W52P1J12C5013
- Award Date
- 3/20/2012
- Awardee
- LESTER CONSTRUCTION, INC. (137055724) <br> 127 1/2 31ST AVE<br> ROCK ISLAND, IL 61201-5916
- Award Amount
- $397,835.00
- Line Number
- 0001
- Description
- * For Subcontracting Purposes Only. Provide design build,labor, material and equipment for access controlled security entry at multiple locations at JMTC Manufacturing Area. Work to include installation of five personnel access locations, shall have allowances for handicapped access via a separate swing gate and shall comprise the Base Bid. All handicapped access gates shall meet minimum requirements of ABA. All personnel access control units shall be mounted on a concrete pad of sufficient dimensions to allow access by the applicable users. All new equipment shall be designed for exterior usage. Each security and handicapped gate will be electrically operated by a PLC board with interface capability for card readers and tie in to existing Simplex security system to accommodate pedestrian traffic. Contractor shall provide electric resistance heating (Tyco Snowmelt or equivalent) in the concrete slab supporting the access control equipment (turnstile and gate as applicable), with controls to minimize electrical usage. All gates locations will have efficiency LED lighting at each card reader for security and night time use of card reader. Contractor shall provide adequate power at each station to support the Card Access Controller (and accessories), gate lighting, one maintenance outlet, in-slab resistance heating(for personnel gates), and power for future security camera hookup. Contractor shall supply and install all necessary access control equipment and programming to connect gates to existing Simplex system. All new equipment must be compatible with the Simplex system.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/475789c397e77f97440b5e2e5b76a5a9)
- Record
- SN02702609-W 20120323/120321235845-475789c397e77f97440b5e2e5b76a5a9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |