SOURCES SOUGHT
J -- McNary Lock and Dam Stoplog Rehab
- Notice Date
- 3/13/2012
- Notice Type
- Sources Sought
- NAICS
- 332312
— Fabricated Structural Metal Manufacturing
- Contracting Office
- USACE District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362-1876
- ZIP Code
- 99362-1876
- Solicitation Number
- W912EF-12-R-SS23
- Response Due
- 3/28/2012
- Archive Date
- 5/27/2012
- Point of Contact
- Valerie Reller, 509-527-7215
- E-Mail Address
-
USACE District, Walla Walla
(valerie.k.reller@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- This announcement constitutes a Sources Sought Synopsis (market survey). This is not a Request for Quote (RFQ) or a Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The U.S. Army Corps of Engineers, Walla Walla District is seeking small business sources for a service requirement entitled: "McNary Navigation Lock Upstream Stop Log Rehab." This will be a firm-fixed-price contract. The purpose of this sources sought is to determine interest and capability of potential qualified small businesses relative to the North American Industry Classification code (NAICS) 332312. The Small Business Size Standard for this NAICS code is 500 employees. To make an appropriate acquisition decision for this project, the Government may use responses to this sources sought synopsis. The type of solicitation issued and the manner of advertisement will depend on the responses to this sources sought synopsis. SUBMISSION REQUIREMENTS FOR RESPONSES TO THIS SOURCES SOUGHT SYNOPSIS (1)Your intent to submit a quote for this project when it is formally advertised (2)Name of firm with address, phone and point of contact. (3)CAGE Code, DUNS number or a copy of your Central Contractor Registration (CCR) information (4)Statement of Capability (SOC) stating your skills, experience, knowledge, and equipment required to perform the specified type of work. This should include documentation of past specialized experience and technical competence in fabricating similar products, up to three (3) past projects for which your firm was the prime contractor. The SOC should be no more than three pages in length. (5)Contractor can handle transportation of the stoplogs due to size and weight constraints. (6)Contractor's facilities can handle the stoplogs due to size and weight constraints. (7)Contractor can handle method of transportation on-water, i.e. barge. Firms responding to this sources sought synopsis, who fail to provide ALL of the required information requested, will not be used to assist the Government in the acquisition decision, which is the intent of this sources sought synopsis. NOTE: IF YOU DO NOT INTEND TO SUBMIT A QUOTE FOR THIS PROJECT WHEN IT IS FORMALLY ADVERTISED, PLEASE DO NOT SUBMIT A RESPONSE TO THIS SOURCES SOUGHT SYNOPSIS. If inadequate responses are received, this solicitation may be issued for full and open competition. Where to send responses U.S. Army Corps of Engineers ATTN: Contracting/Valerie K. Reller 201 North Third Avenue Walla Walla, WA 99362 Phone: (509) 527-7215 Fax: (509) 527-7801 E-mail: Valerie.K.Reller@usace.army.mil Response deadline March 28, 2012 at 2:30 p.m. (Pacific Standard Time) Place of Performance U.S. Army Corps of Engineers, Walla Walla District 201 North Third Avenue Walla Walla, WA 99362 REQUIREMENT DESCRIPTION The work is at McNary Lock and Dam, Umatilla County, Oregon, The job consists of the repair and upgrade to six (6) of the McNary Lock and Dam, navigation lock, upstream stoplogs. The stoplogs are to be strengthened by the addition of gusset plates and bracing. The work will involve welding gussets to structural tee sections, miscellaneous metal work, non-destructive testing (NDT) of welds, installation of structural bracing, possible lead paint abatement, paint preparation and application using US Army Corps of Engineers (USACE) formulation vinyl paint V766e, and purchase and installation of replacement seals and bolts. Gusset plate sizes are typical sizes typically 2.5 feet by 2.5 feet by inch and welding is in accordance with AWS D1.5 and consists of fillet welds at various application directions and locations. Approximate size for each stoplog is 4.5 feet tall, 12 feet wide, 91 feet long and weighing up to 65,000 lbs each. The stoplogs are stored in the upstream storage pits located on the south side of the navigation lock nearest to the Bascule Bridge. The upstream stoplogs will be made available as Government Furnished Property. Method of pickup and delivery will require on-water methods (i.e. barge), due to the stored locations, necessary crane support, logistics and size and weight limitations. The contract pickup and delivery methods will require coordination with the McNary Dam crane operator and operating project staff. The stoplogs will need to be removed by barge within the Navigation lock channel. A specific navigation lock outage schedule, pickup and delivery sequence will be required in order to allow for the most efficient Government support and least impact to the shipping industry. The stoplogs will need to be removed from the McNary project site by barge in ascending order and will be returned in (reverse) descending order to allow for proper stacking in the storage areas. All work activities will be required to be completed prior to Fiscal Year 2013 Navigation Lock Outage period.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF-12-R-SS23/listing.html)
- Place of Performance
- Address: USACE District, Walla Walla 201 N. Third Avenue, Walla Walla WA
- Zip Code: 99362-1876
- Zip Code: 99362-1876
- Record
- SN02694900-W 20120315/120313234749-080ccd3ccdaaabbf14ddac5bde12322a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |