Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 11, 2012 FBO #3731
SOURCES SOUGHT

59 -- Signal Conditioning Amplifier

Notice Date
2/9/2012
 
Notice Type
Sources Sought
 
NAICS
335999 — All Other Miscellaneous Electrical Equipment and Component Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, California, 93524-1185, United States
 
ZIP Code
93524-1185
 
Solicitation Number
F1S0AE-0510GA1A4
 
Archive Date
3/9/2012
 
Point of Contact
Grace H. Watson, Phone: 661-275-4497
 
E-Mail Address
grace.watson@edwards.af.mil
(grace.watson@edwards.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Sources Sought Synopsis - Signal Conditioning Amplifier This is a sources sought synopsis. The Air Force Flight Test Center (AFFTC), 412 Test Engineering Group (TENG), Edwards AFB CA is looking for sources with a demonstrated expertise and experience for a contract to provide brand name or equal compatible hardware and software products meeting the minimum salient characteristics: Item: Signal Conditioning Amplifier, QTY: 5 each Model: 0510GA1A4 Manufacturer: Goodrich Rosemount Aerospace, Inc. SPECIFICATIONS PRT Compatibility -Ice point (R0) of 50, 100 or 500 ohms -Temperature coefficient (a) of.00385,.00390,.003915 or.003925 Ω/ΩºC PRT Leadwire Connections -Three wire with 0.25Ω maximum leadwire resistance Accuracy -Signal conditioner output will be within ±0.25% of Full Scale (FS) for all inputs. Accuracy is based on Root-Sum-Squared (RSS) summation of the following error components: • Long-Term Stability: 0.05% FS (maximum) • Repeatability: 0.1% FS (maximum) • Linearity: 0.15% FS (based on least-squares method) • Temperature Sensitivity: 0.002% FS/ºC (maximum) • Supply Sensitivity: 0.01% FS/volt (maximum) Momentary Power Interruption: Automatic recovery Signal Conditioner Temperature Range Operating: -54ºC to +71ºC (-65ºF to +160ºF) Storage: -65ºC to +125ºC (-85ºF to +257ºF) Reliability Mean Time Between Failure (MTBF) is greater then 100,000 hours (based on MIL-HDBK-217E). Maintainability No scheduled maintenance. Signal conditioner can be repaired and recalibrated. ELECTRICAL SPECIFICATIONS Input Voltage: 28 VDC (nominal) 22-32 VDC Power Requirements: 2 watts (maximum) Output Voltage: 0-5 VDC (nominal) Output Load: 5000 ohms (minimum) Output Isolation: 150K ohms (minimum) from the supply voltage Short Circuit Protection -No damage from continuously shorted output leads Reverse Polarity Protection -No damage from continuously reversed power leads Dielectric Strength: 100 VAC (rms) Insulated Resistance: 100 Megohms (min) at 100 VDC Weight: 7.2 ounces maximum ENVIRONMENTAL SPECIFICATIONS Explosive Atmosphere -Tested to MIL-STD-810, Method 511.1, Procedure I Temperature-Altitude -Tested to MIL-STD-810, Method 504.1, Procedure I Humidity -Tested to MIL-STD-810, Method 507.1, Procedure I Salt Fog -Tested to MIL-STD-810, Method 509.1, Procedure I Fungus -Meets MIL-STD-810, Method 508.1, Procedure I Dust -Tested to MIL-STD-810, Method 510.1, Procedure I Shock -15g's, 11ms, half sine (Tested to MIL-STD-810, Method 516.2, Procedure I) Acoustic Noise -140 db for 30 minutes (Tested to MIL-STD-810, Method 515.2, Procedure I) Random Vibration -Wo =.04 g2/Hz, 2 hours/axis operating (Tested to MIL-STD-810, Method 514.2)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/AFFTC/F1S0AE-0510GA1A4/listing.html)
 
Record
SN02672063-W 20120211/120210114510-efdc40e229fac48f599d9b0c14003094 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.