Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 29, 2012 FBO #3718
SOLICITATION NOTICE

Y -- Decompartmentalization and Sheetflow Enhancement of Water Conservation Area 3, Hydrologic Field Test, Miami-Dade County, Florida

Notice Date
1/27/2012
 
Notice Type
Presolicitation
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
USACE District, Jacksonville, P.O. Box 4970, Jacksonville, FL 32232-0019
 
ZIP Code
32232-0019
 
Solicitation Number
W912EP-12-R-0010
 
Response Due
3/14/2012
 
Archive Date
5/13/2012
 
Point of Contact
Veronica Taylor, 904-232-2107
 
E-Mail Address
USACE District, Jacksonville
(veronica.s.taylor@usace.army.mil)
 
Small Business Set-Aside
Competitive 8(a)
 
Description
The Decomp Physical Model (DPM), also known as the Decomp hydrologic field test, is a large field-scale design test that will address scientific, hydrologic, and water management uncertainties specific to the CERP project Decomp. The goal of the design test is to obtain information to reduce uncertainties involved in the planning of later phases of the Decomp Project and CERP overall. The fundamental uncertainties the design test will address are related to the effects associated with canal backfilling, effects associated with levee removal, and the magnitudes and directions of sheetflow necessary to restore and maintain the landscape characteristics of the Everglades. The design test will be extensively monitored and will adhere to operational constraints described in the Draft Operational Guidance in the April 2010 Final Decomp Physical Model Environmental Assessment & Design Test Documentation Report. The project work consists of installing a new water conveyance structure (Structure 152) on the L-67A levee to convey water from WCA 3A to WCA 3B. S-152 is ten controllable gated 60' diameter culverts with a combined minimum flow of 750 cubic feet per second (cfs). In addition, a 3000 ft gap will be created in the L-67C levee downstream of the S-152 structure. Material from the L-67C gap will be used to construct backfill treatments in the L-67C Canal. 1,000-feet of canal will be backfilled to grade, 1,000-feet will be partially backfilled, and the final 1,000-feet will have no backfill. An additional feature for the contract includes a walkway for the S-152 structure. Contractor shall complete L-67C degrade and backfilling a minimum of 120 calendar days prior to completion of L-67A (S-152). INSTALLATION OF THE STRUCTURE AND BACKFILL PLACEMENT HAS ENVIRONMENTAL SENSITIVITY AS THE WORK IS PREDOMINATELY IN WETLANDS. WORK MAY REQUIRE PLACEMENT OF MATERIALS IN SURFACE WATER. Access to the project site is from US 41 (Tamiami Trail) by S-333 along L-67A and L-67C levees. Work is located in Miami-Dade County, Florida. PROPOSAL REQUIREMENTS: Award will be made to the offeror who submits the Lowest Priced, Technically Acceptable (LPTA) proposal. Proposals will be evaluated based on technical acceptability (demonstrated experience and past performance). Award will be made to the offeror who submits the lowest price proposal that is technically acceptable. Performance period is 180 calendar days. The magnitude of construction for this project is estimated to be between $1,000,000.00 and $5,000,000.00. THIS IS A 8(a) COMPETITIVE ACQUISITION. The geographic area of competition is restricted to 8(a) certified firms in the State of Florida. All firms must have a Small Business Administration bona fide office in the State of Florida. All other firms are deemed ineligible to submit offers. All responsible offerors are encouraged to participate. The solicitation will be issued on or about February 13, 2012 with proposals due on or about March 14, 2012. Solicitation will be issued in electronic format only and will be posted on the Army Single Face to Industry (ASFI) website at https://acquisition.army.mil/asfi/. In order to receive notification of any amendments to this solicitation, interested vendors must REGISTER AS AN INTERESTED VENDOR on the Federal Business Opportunities website at http://www.fedbizopps.gov/. If you are not registered, the Government is not responsible with providing you with notification of any changes to this solicitation. You must be registered in the Central Contractor Registration in order to be eligible to receive an award from this solicitation. Call 1-888-227-2423 for more information or visit the CCR website at http://www.ccr.gov. You also must be registered in Online Representations and Certifications Application (ORCA) in order to receive an award from this solicitation. The ORCA website is located at http://orca.bpn.gov. The NAICS Code is 237990 and the size standard is $33.5 Million Dollars.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA17/W912EP-12-R-0010/listing.html)
 
Place of Performance
Address: USACE District, Jacksonville P.O. Box 4970, Jacksonville FL
Zip Code: 32232-0019
 
Record
SN02662684-W 20120129/120127234405-9ba0df31e0c1a45e7839a015b008211d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers