DOCUMENT
65 -- Endoscopic Surgical Clips and Probes - Attachment
- Notice Date
- 11/9/2011
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VA Boston Healthcare System;Contracting Officer (90C);940 Belmont Street;Brockton MA 02301
- ZIP Code
- 02301
- Solicitation Number
- VA24112Q0123
- Response Due
- 11/14/2011
- Archive Date
- 11/24/2011
- Point of Contact
- Stephen J. Flynn
- E-Mail Address
-
Contracting Specialist
(Stephen.Flynn@va.gov)
- Small Business Set-Aside
- N/A
- Description
- The VA Boston Healthcare System (VABHS) intends to negotiate on a sole source basis pursuant to FAR 6.302-1 -- Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with Boston Scientific Inc., 1 Boston Scientific Place, Natick, Ma. 01760. This requirement will include the following characteristics: Product Description (1) M00522611, CLIP,SURGICAL,ENDOSCOPIC,2.8 MM X 235 CM,OPENING SIZE 11MM, DISPOSABLE,STERILE, PKG: 10 per BX. (2) M00560071, GOLD PROBE #7FR PKG: 5 per BX. (3 M00522612, CLIP,SURGICAL,ENDOSCOPIC,RESOLUTION,2.8 MM X 235 CM,OPENING SIZE 11 MM, DISPOSABLE,STERILE PKG: 20 per BX. Salient Characteristics The Resolution Clip is indicated for clip placement within the Gastrointestinal (GI) tract for the purpose of: Endoscopic marking Hemostasis for: oMucosal/sub-mucosal defects < 3 cm oBleeding ulcers oArteries < 2 mm oPolyps < 1.5 cm in diameter oDiverticulitis in the colon Anchoring to affix jejuna feeding tubes to the wall of the small bowel Closure of GI tract luminal perforations < 20 mm that can be treated conservatively Pre-Loaded-The Resolution Clip Device is designed to be ready-to-use, which is essential for emergency bleeding situations. Re-opening Capability-The radiopaque Resolution Clip is engineered to enable opening and closing up to five times prior to deployment, aiding in repositioning of the clip should that be desired at the lesion site, (Re-opening and closing capability may be limited by clinical circumstances and patient anatomy, among other factors.) 11mm-Wide Jaw Span-The jaw is intended to grasp a sizable amount of tissue. User-Friendly Handle-The handle is designed to deliver a familiar actuation for opening and closing the jaws. It is designed to provide tactile feedback upon closing of jaws, indicating that the clip is about to be deployed. Compatibility-The Resolution Clip Device is designed to be compatible with Gastro scopes and Colonoscopes with working channels equal to or greater than 2.8mm. This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature, to the Contracting Officer no later than November 14, 2011, C.O.B. Responses should be sent to Stephen.Flynn@va.gov. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BoVAMC/VAMCCO80220/VA24112Q0123/listing.html)
- Document(s)
- Attachment
- File Name: VA241-12-Q-0123 VA241-12-Q-0123.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272298&FileName=VA241-12-Q-0123-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272298&FileName=VA241-12-Q-0123-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA241-12-Q-0123 VA241-12-Q-0123.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272298&FileName=VA241-12-Q-0123-000.docx)
- Record
- SN02621045-W 20111111/111109235027-8e09ef2084239bf90fbfef9862257331 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |