MODIFICATION
62 -- Warning Light Stands
- Notice Date
- 11/7/2011
- Notice Type
- Modification/Amendment
- NAICS
- 335110
— Electric Lamp Bulb and Part Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, Tinker OC-ALC - (Central Contracting), 3001 Staff Drive, Ste 1AG76A, Tinker AFB, Oklahoma, 73145-3015
- ZIP Code
- 73145-3015
- Solicitation Number
- FA8126-11-Q-0380
- Archive Date
- 9/3/2012
- Point of Contact
- HICHAM BENHSAIN,
- E-Mail Address
-
HICHAM.BENHSAIN@TINKER.AF.MIL
(HICHAM.BENHSAIN@TINKER.AF.MIL)
- Small Business Set-Aside
- N/A
- Description
- The purpose of this amendment is to add requirement number 14(see description below) and to extend the response date to November 18, 2011. This acquisition is an oral solicitation for Warning Light Stands. A formal solicitation will not be used. The requirement is for 15 each to be delivered to Tinker AFB, Ok, FOB Destination, within 6 weeks of the award effective date. All interested responsible sources are required to submit a quote via email to Hicham.benhsain@tinker.af.mil which shall be considered. WARNING LIGHT STAND SPECIFICATIONS 1. Must have a non-perforated metal frame. 2. Must have 3 rotating warning lights encased in plastic in order from left to right of red, blue, and amber. 3. Must have a horn below the lights which is rated at 100 decibels at 10'. 4. Must include a control box with on/off switches for each warning light directly beneath each warning light and for the horn. 5. Must elevate the warning lights to a minimum height of 54" AFF. 6. Must run on 120V/60Hz power. 7. Must have 100' spring loaded retractable power cord. 8. Must have 6" wheels on the front end and legs on the back end. 9. Must have a pull handle on the front end at a minimum of 40" AFF. 10. Must have all exposed metal surfaces painted yellow for corrosion prevention. 11. Must be constructed entirely out of commercial off-the-shelf (COTS) parts for maintenance purposes. 12. Must have a warning sign with a minimum size of 8.5" X 11" hanging from the control box below the switches. See Appendix A. 13. Must come with an assembly drawing detailing all of the COTS parts and how they are assembled. 14. Must have a fuse to protect the control system and hardware from overcurrent, and must have access to replace the fuse from the back of the control box.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/OCALCCC/FA8126-11-Q-0380/listing.html)
- Place of Performance
- Address: TINKER AIR FORCE BASE, TINKER, Oklahoma, 73145, United States
- Zip Code: 73145
- Zip Code: 73145
- Record
- SN02619513-W 20111109/111107234755-c1ec69584fc65989d9c332d41cdc40ed (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |