SOURCES SOUGHT
B -- Chemical Grout Pump System
- Notice Date
- 10/24/2011
- Notice Type
- Sources Sought
- Contracting Office
- Bureau of Reclamation - Denver Finance Office Finance and Accounting Services, 84-27734PO Box 25007 Denver CO 80225
- ZIP Code
- 80225
- Solicitation Number
- R12SS80044
- Response Due
- 11/7/2011
- Archive Date
- 10/23/2012
- Point of Contact
- Synthia Archuleta Contract Specialist 3034452423 sarchuleta@usbr.gov;
- E-Mail Address
-
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
- Small Business Set-Aside
- N/A
- Description
- Chemical Grout Pump System Solicitation Number: R12SS80044 Announcement Type: Sources Sought NAICS Code: 333911 Please read the requirements thoroughly before making a decision to reply to this notice. The mission of the Bureau of Reclamation is specialized, and, therefore, the services required are also specialized. Qualified firms are highly encouraged to respond. This is a SOURCES SOUGHT ANNOUNCEMENT, a Market Survey for written information only. This is not a solicitation announcement for proposals and no contract will be awarded from this announcement. No reimbursement will made for any costs associated with providing information in response to this announcement or any follow-up information requests. No telephone calls will be accepted. After review of the responses submitted regarding this potential acquisition, a determination will be made whether or not to continue with the procurement under a separate solicitation announcement utilizing Federal Business Opportunities (FedBizOps). The Bureau of Reclamation (BOR) wishes to identify potential sources that can provide a chemical grout pump system that will be used to establish an effective water barrier on dams that have developed cracks that have the potential to for or that has already demonstrated seepage. The BOR is looking for a chemical grout pump system that will properly proportion the resin components, keep the resin components separated until the mixing head, prevent plugging and corrosion, reduce time spent on maintenance, and meet the requirements specified below. REQUIREMENTS: 1. Two component resin injection pump and accessories, capable of pumping low (water) to high viscosity resins (gels and mastics) from low to high pressure: a. Comprised of 3 pump cylinders, 2 for resin/water and one for flushing the injection head. Flushing cylinder to be controlled separately that will prevent quick reaction grouts from plugging the injection head at a safe pressure level; b. Pump to be mounted on a stand that is 1) stable, 2) easy to transport, and 3) easy to move into areas that are difficult to access; c. Pneumatic operation, 16 cfm at 100 psi; d. Delivery rate variable from 0 to 3.2 minimum gpm; e. Adjustable operation discharge - 0 to 3000 psi, minimum; f. Air motor and valving designed so that mixing ratios are always maintained and to prevent resin components from intermixing; g. All metal pump components that come in contact with resin, except pump hoses and suction lines, to be manufactured from stainless steel that prevents corrosion of the cylinders, ball valves, check valves, siphon pipes, recirculation pipes, etc.; h. One regulator to control dispense pressure and one regulator to control flushing pump.Manufactured to be suitable for use with acrylate, polyacrylate, methacrylic acrylate copolymer and acrylic gels, as well as one and two component polyurethane resins. i. Accessories: 25 feet of Teflon lined hose suitable for 3000 psi pressure In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. Complete information must be submitted. Since this is a sources sought announcement, the Government will not contact the concern for clarification of information. This market survey is for planning purposes only and shall not be construed as a request for proposal or as an obligation on the part of the Government. Firms with the capability of providing a chemical grout pump system in accordance with the specifications listed above are encouraged to respond to this notice by completing the questionnaire below. Responses are due by 10:00 a.m. Mountain Time on Monday, November 7, 2011, and should be emailed to sarchuleta@usbr.gov. In order to easily identify your response, be sure to enter "R12SS80044 - Chemical Grout Pump System" in the Subject of the email. ________________________________________________________________________________ Bureau of Reclamation Request for Information QuestionnaireR12SS80044, Chemical Grout Pump System Company Name: Address: Primary Points of Contact (name, title, phone numbers and email addresses): Company Web Address: DUNS Number: NAICS Codes: Small Business categories (if applicable):
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/c06c34ec8e5691dd1f6fcf9b282a0c48)
- Place of Performance
- Address: Denver, CO
- Zip Code: 802250007
- Zip Code: 802250007
- Record
- SN02611649-W 20111026/111024233838-c06c34ec8e5691dd1f6fcf9b282a0c48 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |