Z -- OR A/C Upgrade Baltimore FAR 6.302-5 Authorize or requird by statute Gabco Construction, Service Disabled Veteran Owned Small Business (VAAR 819.7007) - Attachment
- Notice Date
- 9/1/2011
- Notice Type
- Attachment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- VAMHCS Perry Point;PO Box 1000 Bldg. 101 B Room 3;Perry Point, MD 21902
- ZIP Code
- 21902
- Solicitation Number
- VA24511RP0256
- Response Due
- 9/16/2011
- Archive Date
- 10/16/2011
- Point of Contact
- Paul J. Kurzer
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- The Department of Veterans Affairs under the authority of P.L. 109-461, Section 502 as codified in 38 U.S.C. 8127(c), Baltimore VA Medical Center, 10 North Greene Street, Baltimore, MD 21201, intends to solicit and negotiate a sole source contract award for project 512-11-157, Operating Room A/C upgrade, with Gabco Construction, Inc., 716 South Philadelphia Blvd., Aberdeen, MD 21001. This project will be a fixed-price negotiated procurement. NAICS code 238220, size standard $14M. Estimated date of award will be 30 September 2011. The estimated cost of the project will be between $250,000 and $500,000. Under FAR authority 6.302-5 Authorized or required by statue, referencing VAAR 819.7007 Sole source awards to service-disabled veteran-owned small business concerns. Contractor shall remove and dispose of the existing 60 ton 100% outside air handler. The replacement equipment should be properly sized to provide 20% outside air and 80% return air. The system should be designed for outside conditions of 102 degrees F. and 90% relative humidity. Inside conditions in the OR shall be 66 degrees F. while maintaining 30-40% relative humidity. Supply air shall not exceed 55 degrees F. in order to avoid condensation at the diffusers. Minimum air changes shall be 20 air changes per hour during occupied conditions and 8 air changes per hour during unoccupied conditions. Positive pressure shall be maintained at all times. An economizer shall be included in the system as well as two pre-filters (MERV 7 and MERV 11), one after filter (MERV) 14, and one final filter (MERV 17 HEPA). The project shall include all fans, drives (ABB type), DDC controls to comply with the hospital's Johnson Controls monitoring and control system, actuators, dampers heating coils, valves, cooling coils, and humidifiers necessary for the project. The project shall include a UGVI Germicidal Irradiation system. The system shall be selected, designed, installed, wired, commissioned and warranted by the air handling unit manufacturer, for single source responsibility. The UV system shall be powered by the air handling unit power supply, and shall not require any external electrical supplies or connections. The Contracting Office point of contact is Mr. Paul J. Kurzer, paul.kurzer@va.gov, Perry Point VAMC, Perry Point, MD.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAMHCS512/VAMHCS512/VA24511RP0256/listing.html)
- Document(s)
- Attachment
- File Name: VA-245-11-RP-0256 VA-245-11-RP-0256.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=249909&FileName=VA-245-11-RP-0256-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=249909&FileName=VA-245-11-RP-0256-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA-245-11-RP-0256 VA-245-11-RP-0256.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=249909&FileName=VA-245-11-RP-0256-000.docx)
- Place of Performance
- Address: Baltimore VA Medical Center;10 North Greene Street;Baltimore, MD
- Zip Code: 21201
- Zip Code: 21201
- Record
- SN02560588-W 20110903/110902104047-902e0cf9003f1efae0d780ae82a57a39 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |