Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 26, 2011 FBO #3562
MODIFICATION

66 -- MultiRae Pro (Wireless Portable Multi-threat Monitor for Radiation and Chemical Detection)or equal

Notice Date
8/24/2011
 
Notice Type
Modification/Amendment
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
RCO Hawaii (PARC Pacific, 413th CSB), Regional Contracting Office, Hawaii, ATTN: SFCA-POH-H, Building 520, Pierce Street, Fort Shafter, HI 96858-5025
 
ZIP Code
96858-5025
 
Solicitation Number
W912CN11T0559
 
Response Due
8/29/2011
 
Archive Date
10/28/2011
 
Point of Contact
Artenillo Gutierrez, 808-655-3028
 
E-Mail Address
RCO Hawaii (PARC Pacific, 413th CSB)
(artenillo.gutierrez@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a request for information only. This not a request for proposal and there is no solicitation package available at this time. The 413th Regional Contracting Office, Schofield Barracks, Hawaii is seeking sources for the purchase of a MultiRae Pro Wireless Portable Multi-threat Monitor for Radiation and Chemical Detection. 413th Regional Contracting Office is conducting market research to determine the availability of business capable of providing a MultiRAE Pro. The work consists of furnishing all labor, material and equipment necessary to accomplish the following: The contractor shall provide all parts, material, transportation, labor and equipment required to accomplish delivery of a MultiRAE Pro with the required specifications: Sensors Over 30 intelligent interchangeable field-replaceable sensors including gamma radiation, ppb and ppm PID sensors for VOCs, electrochemical sensors for toxic gases and oxygen, combustible LEL and NDIR sensors, and CO2 NDIR sensor Display Readout - Real-time reading of gas concentrations; PID measurement gas and correction factor; battery status; datalogging on/off; wireless on/off and reception quality. - STEL, TWA, peak, and minimum values Keypad Buttons 3 operation and programming keys (Mode, Y/+, and N/-) Sampling Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions Calibration Automatic with AutoRAE 2 Test and Calibration System1 or manual Alarms Wireless remote alarm notification; multi-tone audible (95 dB @ 30 cm), vibration, visible (flashing bright red LEDs), and on-screen indication of alarm conditions - Man Down Alarm with pre-alarm and real-time remote wireless notification Datalogging - Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7) - User-configurable datalogging intervals (from 1 to 3,600 seconds) Communication and Data Download - Data download and instrument set-up and upgrades on PC via charging and PC comm. cradle, travel charger, or AutoRAE 2 Automated Test and Calibration System1 - Wireless data and alarm status transmission via built-in RF modem (optional) Wireless Network RAE Systems Dedicated Wireless Network Wireless Frequency ISM license-free bands Wireless Range (Typical) 656 feet (200 meters) Operating Temperature -4 to 122 F (-20 to 50 C) Humidity 0% to 95% relative humidity (non-condensing) Dust and Water Resistance IP-65/IP-67 (when off) rating Hazardous Location Approvals CSA: Class I, Division 1, Groups A, B, C and D, T4 ATEX: 0575 II 2G Ex ia d IIC T4 Gb IECEx: Ex ia d IIC T4 Gb CE Compliance (European Conformity) EMC directive: 2004/108/EC. R&TTE directive: 1999/5/EC. ATEX directive: 94/9/EC EMI/RFI No effect when exposed to 0.43mW/cm2 RF interference from a 5-watt transmitter at 12" Performance Tests MIL-STD-810F compliant. LEL CSA C22.2 No. 152; ISA-12.13.01 Languages Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, and Swedish Warranty - Two years on non-consumable components and catalytic LEL, CO, H2S, and O2 sensors - One year on all other sensors, pump, battery, and other consumable parts 1 Contact RAE Systems for availability. 2 RAE Systems recommends calibrating sensors on installation. 3 Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission. 4 The CO + H2S combo sensor is required for a 6-threat configuration. 5 Specifications are subject to change. **Contact Point of Contact listed below for complete list of Sensor Specifications. Contract Type: Supply Information Required: If you company is interested, please provide the following information. *Company Name, Point of contact, Email Address, Telephone and Facsimile numbers, and Type and Business Size (i.e. HUBZone, 8(a), SDVOSB, etc. Please submit all the above information no later than 29 August 2011. It may be submitted by e-mail, fax, or by U.S. mail. If you have any questions please feel free to contact: SSG Artenillo Gutierrez Contract Specialist Building 692 Basement McCornack Road Schofield Barracks, HI 96786 E-mail: artenillo.gutierrez@us.army.mil Phone: 808-655-3028 Facsimile: 808-655-7350 This is for informational purposes only. All information submitted is voluntary. The government will not pay for information gathered as a result of this notice.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/6a19866579111fb107b06ec81370c788)
 
Place of Performance
Address: RCO Hawaii (PARC Pacific, 413th CSB) Regional Contracting Office, Hawaii, ATTN: SFCA-POH-H, Building 520, Pierce Street Fort Shafter HI
Zip Code: 96858-5025
 
Record
SN02546819-W 20110826/110824235208-6a19866579111fb107b06ec81370c788 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.