Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 26, 2011 FBO #3562
SOURCES SOUGHT

63 -- High Power Speaker Array (HPSA)

Notice Date
8/24/2011
 
Notice Type
Sources Sought
 
NAICS
334310 — Audio and Video Equipment Manufacturing
 
Contracting Office
RCO Hawaii (PARC Pacific, 413th CSB), Regional Contracting Office, Hawaii, ATTN: SFCA-POH-H, Building 520, Pierce Street, Fort Shafter, HI 96858-5025
 
ZIP Code
96858-5025
 
Solicitation Number
W912CN11T0564
 
Response Due
8/29/2011
 
Archive Date
10/28/2011
 
Point of Contact
Artenillo Gutierrez, 808-655-3028
 
E-Mail Address
RCO Hawaii (PARC Pacific, 413th CSB)
(artenillo.gutierrez@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a request for information only. This not a request for proposal and there is no solicitation package available at this time. The 413th Regional Contracting Office, Schofield Barracks, Hawaii is seeking sources for the purchase of a High Power Speaker Array. 413th Regional Contracting Office is conducting market research to determine the availability of business capable of providing a High Power Speaker Array. The work consists of furnishing all labor, material and equipment necessary to accomplish the following: The contractor shall provide all parts, material, transportation, labor and equipment required to accomplish delivery of a High Power Speaker Array with the required specifications: Power Input Voltage: 100/240 VAC +/- 10% 50-60 Hz Single-phase Input Current: 5 Amps. Max (average 3.2 amps at 120V / 1.6 amps at 220V) Battery Input: Voltage: 43.5 - 55.4 VDC 48 Volts (nom) Operating Voltage: 48 VDC Max Standby Time: >7 Days Standby Time: Greater than 72 hrs followed by 60 min continuous voice (UFC Compliant) Continuous Signaling Time: >60 minutes (voice) Self protected against deep discharge Battery Charger: Universal AC; Solar panel input available Solar Panels: Optional - size depends on specific requirements Control Module Signal Duration(auto reset): Unlimited Microphone Input Impedance: 600 Ohms Audio Distortion:.1% THD Maximum Load: 600 Ohms Audio Out: 1 Vrms differential Audio In: 1 Vrms differential Contact Closure: 250ms < 1.0 K Ohms* (Optional Equipment WIML) Relay Output: 30 Vdc, 3A Amplifiers Amplifier Class: Class D Frequency Response: 20 Hz - 20 KHz; +/- 3db (C) Total Harmonic Distortion:.1% THD Efficiency: Not less than 90% at full load Thermal Protection: Yes Short circuit protection: Yes, Auto Recovery Enviromental Operating Temperatures: -25 C to +60 C or -13F to +140 F Lightning Protection: Built-In lightning protection on mains, solar panel and speaker lines Physical Electronics Cabinet Dimensions: 34.5" W x 49" H x 12.5" D (88 x 124 x 32 cm) Electronics Cabinet Weight: 179 kg/394 lbs. (Batteries: 111 kg/244 lbs; Cabinet and Electronics: 68 kg/150lbs) Engineer Specifications Siren Electronics shall be: One (1) outdoor wallmount cabinet, with terminations and all components fully assembled and tested 110 or 240V power supply Fused lightning protection Include a motherboard with power supply interface, amplifier and driver test module Sound processor with alarm tone signal generator that can be configured with virtually an unlimited number of local tones and messages 60-minute internal speech storage unit Local control panel for alarm activation, PA, test and configuration setup, RS-232 Serial Interface; Radio Interface-WAVES TRX interface Interface to WAVES via TRX-401 or COTS radio and specialized interface band Interfaces to other control systems available Siren Head shall be: 2-16 high efficiency aluminum horns 2-16 100W drivers with connectors with one (1) set, mounting materials (screws, nuts, washers) Contract Type: Supply Information Required: If you company is interested, please provide the following information. *Company Name, Point of contact, Email Address, Telephone and Facsimile numbers, and Type and Business Size (i.e. HUBZone, 8(a), SDVOSB, etc. Please submit all the above information no later than 29 August 2011. It may be submitted by e-mail, fax, or by U.S. mail. If you have any questions please feel free to contact: SSG Artenillo Gutierrez Contract Specialist Building 692 Basement McCornack Road Schofield Barracks, HI 96786 E-mail: artenillo.gutierrez@us.army.mil Phone: 808-655-3028 Facsimile: 808-655-7350 This is for informational purposes only. All information submitted is voluntary. The government will not pay for information gathered as a result of this notice.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/6bc821bde94c5cf957608da608b3b5d4)
 
Place of Performance
Address: RCO Hawaii (PARC Pacific, 413th CSB) Regional Contracting Office, Hawaii, ATTN: SFCA-POH-H, Building 520, Pierce Street Fort Shafter HI
Zip Code: 96858-5025
 
Record
SN02546812-W 20110826/110824235203-6bc821bde94c5cf957608da608b3b5d4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.