Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 13, 2011 FBO #3549
SOLICITATION NOTICE

46 -- W912DW-11-Q-0156; UV Disinfection System; Please see attached solicitation

Notice Date
8/11/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
221320 — Sewage Treatment Facilities
 
Contracting Office
USACE District, Seattle, ATTN: CENWS-CT, PO Box 3755, Seattle, WA 98124-3755
 
ZIP Code
98124-3755
 
Solicitation Number
W912DW-11-Q-0156
 
Response Due
8/18/2011
 
Archive Date
10/17/2011
 
Point of Contact
Jason G. Herrera, 206-764-6662
 
E-Mail Address
USACE District, Seattle
(jason.g.herrera@usace.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The Army Corps of Engineers at Libby Dam is purchasing an open channel gravity flow ultraviolet disinfection system. The ultraviolet disinfection system will be connected to an existing package treatment plant for sewage treatment purposes at Libby Dam. The specified system shall be capable of treating 14,000 gallons per day guaranteeing that the effluent does not exceed 126 e-coli/100ml (based on a 30 day geometric mean of daily samples). The specified system shall be 100% redundant meaning that two banks of UV lights in series shall be supplied each meeting the minimum requirements for sewage treatment. The maximum dimensions of the system shall not exceed 14' x 2' x 3' (Length x Width x Height). All interested parties shall submit documentation verifying conformance to the following requirements: 1. To be considered, the manufacturer will be regularly engaged in the manufacture of UV systems with a proven track record of at least one hundred (100) installations in North America. 2. The manufacturer will provide documentation of previous experience with municipal UV disinfection systems in wastewater applications with electronic ballasts. 3. Pre-qualification submittals from manufacturers will include a complete and detailed proposal of equipment offered, including the number of lamps proposed and a detailed description of any exceptions taken to the specification. 4. To be considered, the manufacturer will submit a bioassay evaluation for the proposed reactor. This bioassay will have been validated by an independent third party and have followed protocols described in the US EPA Design Manual - Municipal Wastewater Disinfection (EPA/625/1-86/021), without exception. The manufacturer's bioassay report must demonstrate that the proposed UV system design and number of lamps will deliver the specified dose. 5. Independent certification of lamp aging factor must be submitted. 6. Documentation of UV manufacturer's service capabilities including location and experience. 7. Sample disinfection performance guarantee including scope and duration of guarantee. The total quantity is 1 fully redundant unit
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA67/W912DW-11-Q-0156/listing.html)
 
Place of Performance
Address: USACE District, Seattle ATTN: CENWS-CT, PO Box 3755 Seattle WA
Zip Code: 98124-3755
 
Record
SN02530046-W 20110813/110811234905-f706aa663783884a7969ee3f5fa2ba4f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.