SOURCES SOUGHT
41 -- USACE, Seattle District is seeking manufacturers and/or distributors of ductless, split system A/C unit/Mini-Split/or VRF Systems. Must meet requirements of Buy American Act, specifically FAR 52.225-9 Buy American Act
- Notice Date
- 7/8/2011
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- USACE District, Seattle, ATTN: CENWS-CT, PO Box 3755, Seattle, WA 98124-3755
- ZIP Code
- 98124-3755
- Solicitation Number
- W912DW-11-R-SS00
- Response Due
- 7/22/2011
- Archive Date
- 9/20/2011
- Point of Contact
- Kathaleen Schollard, 2539664369
- E-Mail Address
-
USACE District, Seattle
(kathaleen.schollard@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- SOURCES SOUGHT SPLIT DUCTLESS HVAC SYSTEM SYNOPSIS: 1. The U.S. Army Corps of Engineers, Seattle District is seeking manufacturers and/or distributors of ductless, split system A/C unit/Mini-Split/or VRF (Variable Refrigerant Flow) Systems. Units must meet requirements of Buy American Act, specifically FAR 52.225-9 Buy American Act - Construction AND be Energy Star Compliant, in accordance with Federal Energy Management Plan requirements and FAR Part 23.203. The requirements for these systems are described in paragraph two (2) below. 2. TECHNICAL REQUIREMENTS: a. Unit shall meet FAR 52.225-9, Buy American Act - Construction b. Unit must comply with FAR Part 23.203 and Federal Energy Management Plan Requirements for Energy Star products. c. Unit shall have a minimum SEER rating of 14. d. Unit shall have a minimum EER rating of 12. e.Unit shall utilize Refrigerant R410A. f. Unit shall be able to maintain system operation at ambient temperature down to zero degrees Fahrenheit. g.Unit shall maintain room space temperature/Drift Point" of 72 degrees F and Relative Humidity of 50% b. SUBMISSION REQUIREMENTS: a.Manufacturers and/or suppliers responding to this announcement shall submit the technical specifications, as noted below, for ALL units/sizes that meet the minimum technical requirements defined in Paragraph 2 of this announcement, as follows: a.Size/Capacity: 1 ton, 1.5 ton, 2 ton, 3 ton, etc (12k, 18k, 24k, 36k BTU, etc). b.SEER Rating c.EER Rating d.Refrigerant Type e.Maximum horizontal and vertical lengths of the refrigerant line set f.Fixed or Variable Speed Cooling g.Whether or not the unit has removable access to controls without interrupting airflow and allow for service without the use of special tools. Condensate pans shall be non-corroding and double sloped. Wall mounted or ceiling mounted. External thermostat, internal thermostat not acceptable. Type of condensate pan (whether corroding or non-corroding and the type of slope Wall mounted, floor mounted, or ceiling mounted Whether the thermostat is internal or external Whether the fans and compressors are fixed or variable speed Whether the condenser circuits pre-piped with start up and head pressure controls Whether the unit has a side or top discharge b.A catalog cut of the units with technical specification demonstrating all compliant units shall be included. c.Provide approximate cost and place of manufacture for each unit. Responses should be submitted to the indicated point of contact with company name, address, and point of contact including email address. Responses must be received no later than 2:00 p.m. Pacific Time on 22 July 2011.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA67/W912DW-11-R-SS00/listing.html)
- Place of Performance
- Address: USACE District, Seattle ATTN: CENWS-CT, PO Box 3755 Seattle WA
- Zip Code: 98124-3755
- Zip Code: 98124-3755
- Record
- SN02492878-W 20110710/110708234309-4b15f02645e25940f14e126524b76386 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |