SOLICITATION NOTICE
66 -- Dionex Chromeleon Operated Ion Chromatography (IC) System
- Notice Date
- 7/5/2011
- Notice Type
- Presolicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Environmental Protection Agency, Office of Acquisition Management, Region V, Acquisition and Assistance Section (MMC-10J), 77 West Jackson Boulevard, Chicago, Illinois, 60604
- ZIP Code
- 60604
- Solicitation Number
- PR-R5-11-00716
- Archive Date
- 8/3/2011
- Point of Contact
- Jessica Strattard, Phone: (312) 353-4657, Donald K. Anderson, Phone: (312) 886-7159
- E-Mail Address
-
strattard.jessica@epa.gov, anderson.donald@epa.gov
(strattard.jessica@epa.gov, anderson.donald@epa.gov)
- Small Business Set-Aside
- N/A
- Description
- The government intends to solicit and negotiate with only one source under the authority of FAR 13.106-1(b)(2), and FAR 6.302-1(a)(2)(ii). This synopsis is being published for informational purposes only. This notice of intent is not a request for competitive quotations; however, all quotations/responses received within seven (7) days of the issuance of this notice will be considered by the Government. Further determination by the Government not to compete this proposed contract action based upon responses to this notice is solely within the discretion of the Government. The USEPA will not consider split awards for these items. Specifications: Instrument Requirements: 1. The basic unit shall be a chromeleon operated ion chromatography (IC) system. The IC system shall consist of a Dual Pump, Mobile Phase (Eluent) generator, Electrolytic Suppression (self-regenerating), Conductivity Detector, Absorbance Detector, and Data Systems. 2. The IC system must be able to connect and operate seamlessly with an existing mass spectrometer (Dionex MSQ) using chromeleon software. 3. The system shall be operated with existing chromeleon based data system which includes remote client and other licenses already in place. 4. The Mobile Phase shall be produced by means of an automated on demand continuous generation system during analysis. Manual mobile phase preparation shall be a limited option for minor application. 5. The mobile phase shall move through the IC systems by means of pressure from a pump. Such a pump should have a pressure range of 0 - 6000 psi (0 - 41 MPa), low noise, reproducible flow rate, a pressure rating greater than 4,000 psi, and compatible with a wide range of solvents and additives. A dual pump configuration is required for this system. 6. Sample introduction shall be by means of an auto-sampler and sample loops. The auto-sampler shall be capable of sequential injection, auto-dilution, large loop injection, and in-line sample pH and conductivity measurements. The system should provide for in-line filter 7. The system shall be readily configured for either capillary or standard bore application when needed. 8. Conductivity and Absorbance detectors provided should each have high sensitivity, wide linear range, fast response time, low noise, small dead volume, and should not respond to the mobile phase under selected test conditions. 9. The absorbance detector should be equipped with Deuterium and Tungsten lamps and cover wavelength from190 - 900 nm. Notice for the acquisition of the following Dionex equipment, sole source: Qty/Product 1 Nitrogen Gas Generator 1 AGREEMENT,SVC,PREMIER CARE Duration 1 YR 1 AS-AP Autosampler, Base Configuration 1 AGREEMENT,SVC,PREMIER CARE Duration 1 YR 1 Valve Assembly, includes one 2 way 10-port Valve and Mounting Hardware 3 AS-AP 1.5/0.3 mL Vial Tray 1 DP Analytical Isocratic - Analytical Isocratic with Degas 1 AGREEMENT,SVC,PREMIER CARE Duration 1 YR 1 PROD,EO+2 ELUENT BTLS,ICS5 1 EG Eluent Generator Module (Does NOT include EG Degasser) 1 GREEMENT,SVC,PREMIER CARE Duration 1 YR 1 EG Cartridge Kit: Degasser and Tubing (Analytical) 1 Potassium Hydroxide Eluent Generator Cartridge (EGC III KOH) 1 CR-ATC Continuously Regenerated Anion Trap Column 1 CD Conductivity Detector (analytical) and Integrated Cell 1 AGREEMENT,SVC,PREMIER CARE Duration 1 YR 1 PROD,VWD-IC, 2G, 1 CHANNEL 1 AGREEMENT,SVC,PREMIER CARE Duration 1 YR 1 AXP Auxiliary Pump 1 AGREEMENT,SVC,PREMIER CARE Duration 1 YR 2 Chromeleon Class 1 Timebase 8 Power Cord US 1 Installation Module IC System with Dual Pump Setup incl. Operator Orientation 1 DC, Dual Temperature Zones, Two Injection Valves, Standard Bore 1 Knitted Reaction Coil, 750 μL, Unpotted 1 Absorbance Cell, 11 μL, 10 mm Path Length, PEEK 1 IonPac AS7 Analytical Column (4 x 250 mm) 1 IonPac NG1-10 μm Guard Column (4 x 35 mm)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/EPA/OAM/MMC-10J/PR-R5-11-00716/listing.html)
- Place of Performance
- Address: 536 S. Clark, Chicago, Illinois, 60605, United States
- Zip Code: 60605
- Zip Code: 60605
- Record
- SN02489214-W 20110707/110705234041-a6abd31f8e0760eb7bb965e4ff0aa4e5 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |