Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 05, 2011 FBO #3480
SOLICITATION NOTICE

K -- New Fire Alarm Replacement and Wet Sprinkler System Modification

Notice Date
6/3/2011
 
Notice Type
Presolicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Property Management Division- Ohio Service Center, General Services Administration, Public Building Service, 201 Superior Avenue, Cleveland, Ohio, 44114, United States
 
ZIP Code
44114
 
Solicitation Number
GS05P11SLC0067_ROH00428
 
Point of Contact
Rhonda Booker, Phone: 216-522-4875, Kimberly R Bogan-ridley, Phone: 312-353-4221
 
E-Mail Address
Rhonda.Booker@gsa.gov, kim.bogan-ridley@gsa.gov
(Rhonda.Booker@gsa.gov, kim.bogan-ridley@gsa.gov)
 
Small Business Set-Aside
N/A
 
Description
This synopsis is for the purpose of pre-solicitation notification only. NO SOLICITATION IS ATTACHED. A SOLICITATION WILL BE POSTED ON OR ABOUT June 18, 2011. DESCRIPTION The following work will be performed at the Joseph P. Kinneary US Courthouse, 85 Marconi Blvd., Columbus, Ohio 43215. SUMMARY This project is for a Firm-Fixed-Price type contract. This procurement will be solicited on a full and open unrestricted bases. The work of this project is defined by the Contract Documents. The project includes, but is not limited to the following: The contractor will be tasked with installing a complete, supervised, non coded addressable/Multiplex voice-type fire alarm system that is independent and separate from other building systems. Installation shall be in accordance with the latest edition (2010) of National Fire Protection (NFPA) Standard No. 72, GSA facilities Standards and for Public Building Services PBS - P100 (December 2009), ICC International Building Code, and the American With Disabilities Act Accessibility Guidelines (ADAGG). The latest GSA Guide Specification (28 31 01) 16723, Multiplex/Addressable Voice Evacuation Fire Alarm System shall be utilized/edited. The installation shall include but is not limited to the following: •· All new wiring utilizing red anodized conduit, raceway, terminal cabinets, outlets and mounting boxes, control equipment, alarm and supervisory signal initiating devices, alarm indicating devices, addressable devices, field addressable interface devices, audible and visual notification appliances. •· Style 7 (Class A) signaling line circuit for the network, Style 4 (Class B) signaling line circuit for each floor, Style B (Class B) initiating device circuits, and Style Y (Class B) notification device circuits for a complete and operable system. •· A minimum of two (2) distinct fire alarm notification appliance circuits and a minimum of two (2) distinct visible notification appliance circuits. •· Install new fire alarm speakers conforming to UL 1480. •· Install visual notification appliances (strobes) that operate on a supervised twenty-four (24) volt D.C. circuit. •· Install new multi-technology smoke detectors in each elevator lobby and elevator machine rooms, building corridors where common path of travel exceeds 100ft. travel distance, provide new photoelectric duct smoke detectors that will automatically initiate the shutdown of its dedicated air-handling units on the supply and the return side of the units, (Supervisory Alarm). •· Install new fire alarm speakers in the stairways and elevator cabs on a separate communication zone for manual activation. •· Install new manual fire alarm pull stations. •· Install an automated voice-type alarm system with pre-recorded messages coordinated with GSA. •· Provide complete demolition of the existing fire alarm system after completion/testing/programming and sign-off of the new fire alarm system. Modify the existing wet-pipe automatic sprinkler system to provide complete fire protection throughout the facility. Installation shall be in accordance with the latest edition of National Fire Protection Association (NFPA) Standard No. 13, GSA Facilities Standards for the Public Buildings Services PBS-P100 (December 2009) and ICC International Building Code. The latest edition of GSA Guide Specification 21 13 13 (15330) shall be utilized/edited as needed. The installation shall include the following: •· Additional sprinklers, piping, hangers, etc. in areas with inadequate sprinkler coverage for the first floor south historic corridor between the east and west stairways and the third floor south courtroom #331, adjacent corridor, judges chamber, & kitchen area. •· Provide a new Sprinkler installation in Historical Areas like First Floor Lobby and Corridors, Third Floor Historic Corridor and Historic Courtroom on Third Floor. System shall be fully integrated into the New Fire Alarm System. •· Install new water flow detectors, pressure switches and tamper switches for each building sprinkler system, all such existing devices shall be replaced. The Work shall be conducted in one phase, with each phase substantially complete as indicated in specifications. The magnitude of this construction project (per Federal Acquisition Regulation, 36.204 Disclosure of the magnitude of construction projects) is estimated between $1,000,000.00 and $2,000,000.00. The RFP solicitation is anticipated to be issued on or about June 18, 2011. Offers will be due on or about July 18, 2011 (the actual date of receipt for proposals will be stated on the solicitation). No public bid opening procedures are applicable for this solicitation. The 2007 North American Industrial Classification System (NAICS) code applicable to this project is 238210 with a size standard of $14 million. Large businesses proposing under this unrestricted procurement may be required to submit a subcontracting plan, please consult RFP documents. This solicitation will be issued via Internet only on FedBizOpps Website at www.fbo.gov. Notification of amendments shall be made via FedBizOpps Website only. It is the contractor's responsibility to check the below listed Internet address daily for any posted changes to this solicitation. No corrections and/or changes to proposals will be allowed after the proposal submittal due date and time. After solicitation issuance, contractors may view and/or download this solicitation and all amendments at the following internet address: www.fbo.gov. The use of the website requires prior registration at www.fbo.gov. The plans and specifications will be provided through the federal business opportunity website. The plans and specifications will not be made available in paper format or on compact disc. A pre-proposal conference will be conducted before the proposal due date (actual information will be contained in the solicitation). The solicitation will be available for download through the Federal Business Opportunities (FBO) website ( www.fbo.gov ). All interested contractors must register with FBO in order to view sensitive but unclassified information, and this registration requires that the following information be completed: (1) An active Central Contractor Registration (CCR) account, and (2) Dun and Bradstreet DUNS Number. It is the Offeror's responsibility to monitor the FedBizOpps web site for amendments to the solicitation. All contractors need to be registered in CCR and ORCA. You may register at www.bpn.gov. Proposals will be due to the General Services Administration, Public Building Service, Ohio Service Center, 201 Superior Avenue, Suite 450, Cleveland, OH 44114, ATTN: Rhonda Booker, no later than the date and time specified on the solicitation. Electronic and fax proposals will not be accepted.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/5PT2/GS05P11SLC0067_ROH00428/listing.html)
 
Place of Performance
Address: JOSEPH P. KINNEARY US COURTHOUSE, 85 Marconi Blvd., Columbus, Ohio, 43215, United States
Zip Code: 43215
 
Record
SN02463291-W 20110605/110603234150-95d12128ad4fc6620c5e298adead59d9 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.